Datasheet Fire Alarm Systems Incident Commander Version 6.02 ULC CSFM Listed FM Approved with Simplex ES Net and 4120 Networks TrueSite Commander provides 4100ES mounting for the Simplex Workstation All in one touchscreen computer monitor mounts in a 4100ES and is powered from the fire alarm system power supply battery backup Seismic hardware 4100ES mounting with battery brackets provides area protection High resolution touchscreen monitor Includes Windows 10 Enterprise 64 bit Hinged mounting bracket allows convenient service access Available for desktop use operating at 120 VAC with an included supply module Incident Commander function summary Simplex fire alarm network connected graphical interface control Connects to the Simplex fire alarm network as a node allowing to remote control unit activity status and for a Mass Notification event or a fire alarm event can take control of remote control activity over the fire alarm network Available TCP IP LAN WAN connections you can connect up to 20 clients on a 4120 network or 60 remote clients on an ES Net to the server for multiple remote users with dedicated and Fire Alarm LAN equipment listed remote clients can have control Supports standard fire service annunciation icons to provide and first responders with critical fire response information Custom alarm and system messages guide emergency responders important information Color graphical annunciation and control capacity for up to ES Net network points or up to 100,000 4120 network points ES Net version compatibility and 4120 version compatibility for details Floatable and dockable windows allows windows to either be fixed or floatable lockout Password security supports 8 to 16 alphanumeric passwords with Backup utility can be configured to automatically backup specified including TSW job data to the secondary hard drive The utility is available to systems that do not use RAID Multiple password controlled operator levels 3rd Party Interface open architecture solution provides enhanced access for advanced users Available optional connections for printers or other compatible Dual monitor support allows the Alarm List Window to be on one and the Graphics Window on the other Operating systems Server and clients are compatible with Windows Professional or Enterprise Clients are also compatible with 10 Home 32 bit and 64 bit for all options Extensive historical logging up to 500,000 events with operator screens details 1 TrueSite Incident Commander mounts in bay two a 4100ES control unit shown with master controller 2 Desktop TrueSite Incident Commander Pan and zoom features allow precise navigation Configurable coverage zones allow highlighted areas of activity in Auto jump allows the screen view to jump to a graphic or alarm list defined zones Incident Commander system features TrueSite workstation mobile client allows compatible iOS and devices to access system information Export to XML feature allows TrueSite Workstation data to be easily for report generation and customization Test mode allows unobtrusive testing of selective devices without interruptions Node name allows a description of the specific building or area with a point in views and reports Vector information to supervised remote clients select by point category control unit or custom list Email generation is available to send updates to individuals or to lists with selectable content to Product Selection tables for specific product listing details CSFM Listing 7300 0026 323 At the time of publication only UL and ULC listings are applicable to ES Net network products listings may be applicable contact your local product supplier for the latest status S4190 0020 Rev 25 1 2022 Sound files WAV can be used to create custom audible status with Agency listed desktop PC model 4190 7014 Fahrenheit or Celsius temperatures can be displayed Optional interface to digital alarm communicator receiver integrates multiple systems onto a single Incident Commander DACR account filter allows historical log reports to be filtered by account for quick access and verification Operator notes allows an operator to log operator notes associated individual events for historical records and retrieval Web browser command link allows an external web page or link web cam to be called with a single command RAID 1 support provides a real time image on a secondary drive for enhanced life safety workstation survivability RAID is available to systems that do not use the Backup Utility Software maintenance agreement SMA provides access to new features as well as cyber security and compatibility updates year included with new system with an option to renew listings UL 864 as Fire Alarm Control Unit Annunciator UOXX S771 UL 864 as Fire Alarm Proprietary Supervising Station Control Unit UL 864 as Firefighter Smoke Control Station UUKL S771 UL 1076 as Proprietary Burglar Alarm Unit APOU BP2801 UL 1610 as Central Station Burglar Alarm Control Unit AMCX S771 UL 2572 as Mass Notification System Supervising Station Control Unit PGWM S232 see Mass notification systems reference details ULC S527 as Fire Alarm Control Unit Annunciator UOXX7 S771 ULC S527 Commercial Supervising Control Unit UOJZ7 S771 ULC ORD C100 Smoke Control System Equipment for Canada ULC ORD C1076 Proprietary Alarm System Annunciator APOU7 S771 UL 1076 Proprietary Burglar Alarm Multiplex Receiving Unit ULC S559 Central Station Fire Alarm System Receiving Station fire alarm network capabilities Multiple TrueSite Incident Commanders and TrueSite workstations be nodes on the same fire alarm network to provide redundant for improved survivability Standard fire alarm network connection for wired or fiber optic media Connect to up to seven 7 separate network loops with 4120 limited a maximum of two 2 loops Graphical network diagnostic tools Set host service functions allow access to remote network node data individual TrueAlarm analog sensors Provides event printing with compatible printer view or print status service reports TrueAlert self test reports and graphic screens Refer to TrueSite Workstation datasheet S4190 0016 for additional detail TrueSite Incident Commander offers TrueSite Workstation operation an all in one package providing a touchscreen computer monitor drive and required input output connections in single assembly allows installation within a 4100ES fire alarm control unit or remote with power supplied from the fire alarm power supply secondary batteries The all in one computer is also available for applications requires separate AC power Incident Commander Version 6.02 Annunciation Incident Commanders provide annunciation status display control for Simplex Fire Alarm Networks using a personal computer graphical interface with a high resolution color display Response with realistic icons provide control switches specific to the being performed Clients remote viewing of TrueSite Incident Commander Server information clients are available and connected using TCP IP LAN WAN communications As discussed in Server client operation Clients can be annunciation only or capable of system control configured with agency listed hardware Compatible systems requiring information from remote control units through Digital Alarm Communicator Transmitters Incident Commanders be equipped to communicate directly with a compatible DACR Refer datasheet S4190 0028 for more DACR details Incident Commander operation When fire alarm network status changes occur the screen the type and location of the alarm or other activity and the header buttons appear In the historical log screen as in Figure 3 Fire Priority 2 Supervisory and Trouble buttons shown with an active Trouble indicated