Simplex TrueAlarm Fire Alarm Systems, Fire Alarm Network Annunciators; TrueSite Workstations

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Simplex TrueSite Workstation TSW is a next generation platform manages an entire fire and life safety network from a single location PC based graphical command center provides centralized network historical logging report generation and control of fire network points 1 TSW desktop application Simplex fire alarm network connected graphical interface control with Simplex ES Net and 4120 networks Available TCP IP LAN WAN connections up to 20 remote clients a 4120 network or 60 remote clients on an ES Net network can be to the server for multiple remote users with dedicated and Fire Alarm LAN equipment listed remote clients can have control Supports standard fire service annunciation icons to provide and first responders with critical fire response information Custom alarm and system messages can intuitively guide responders important information such as HAZMAT contact information and more can be quickly presented Color graphical annunciation and control capacity for up to ES Net network points or up to 100,000 4120 network See ES Net software compatibility and 4120 network software for additional details Floatable and dockable windows allows windows to either be fixed or floatable Quad monitor support allows multiple active windows or run client server instances on individual monitors with up to four supported monitors Pan and zoom features allow precise dynamic navigation within graphic screen for rapid and convenient selection of the area of Configurable coverage zones allow user defined areas or zones a graphics screen to indicate the area of activity without into the point of interest Auto jump allows the screen view to automatically jump to a graphic a predetermined zoom level with the active device centered on the alternately the system can be selected to auto jump to the List window Captive or non captive modes support dedicated workstation captive or workstation operation with other Windows such as word processing spreadsheet and more where activity takes precedence non captive Extensive historical logging up to 500,000 events with operator information is spreadsheet and database compatible for customization Fire Alarm Systems Workstations Version 6.02 Optional interface to Digital Alarm Communicator Receiver integrates multiple systems onto a single workstation DACR account filter can filter historical log reports easily Multiple password controlled operator levels with selectable feature 3rd Party interface open architecture solution provides enhanced access for advanced users Available optional connections for printers or other compatible Operating systems Server and clients compatible with Windows 10 or Enterprise 32 bit and 64 bit Clients also compatible Windows 10 Home 32 bit and 64 bit TrueSite Workstation mobile client allows compatible iOS and devices to access system information Export to XML feature allows TrueSite Workstation data to be easily for report generation and customization Test mode allows unobtrusive testing of selective devices without interruptions at the operator workstation Password security supports 8 to 16 alphanumeric passwords with lockout for failed attempts Operator notes allows an operator to log notes associated with events for historical records and retrieval Web browser command link enables the ability to easily call up an web page or link such as web cam and more with a single button on a graphic screen RAID 1 support provides a real time mirror image on a secondary drive for enhanced life safety workstation survivability operation automatically transition to the alternate drive on a drive failure loss of operation RAID support is available to systems that do use the Backup Utility Backup utility can be configured to automatically backup specified including TSW job data to the secondary hard drive The Utility is available to systems that do not use RAID Vector information to supervised Remote Clients select by point category panel or custom list Email generation is available to send updates to individuals or to lists with selectable content Sound files WAV can be used to create custom audible status using local onboard speakers Fahrenheit or Celsius temperatures can be displayed for screens heat sensor temperatures Software Maintenance Agreement SMA provides access to new features as well as cyber security and compatibility updates first year is included with the new system with an option to renew listings UL 864 as Fire Alarm Control Unit Annunciator UOXX S771 UL 864 as Fire Alarm Proprietary Supervising Station Control Unit UL 864 as Firefighter Smoke Control Station UUKL S771 UL 1076 as Proprietary Burglar Alarm Unit APOU BP2801 UL 1610 as Central Station Burglar Alarm Control Unit AMCX S771 UL 2572 as Mass Notification System Supervising Station Control Unit PGWM S232 see Fire smoke control station reference details ULC S527 as Fire Alarm Control Unit Annunciator UOXX7 S771 ULC S527 Commercial Supervising Control Unit UOJZ7 S771 ULC ORD C100 Smoke Control System Equipment for Canada to Product Selection tables for specific product listing details CSFM Listing 7300 0026 323 Accepted for use City of New York Department of Buildings MEA35 93E does not include model At the time of publication only UL and ULC listings are applicable to ES Net network products Additional listings may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection Products Rev 47 5 2021 Workstations Version 6.02 control access levels access level is determined during log in Select functional to match the training and responsibility of the operator with additional TrueSite Workstation and fire alarm network may be qualified for access to sensitive areas For operators who primarily concerned with immediate facility security a lower level will provide the information necessary for proper response but not allow access to key parameters that determine overall system operation diagnostics network status views built in diagnostics are available to provide graphical views network topology and network status Missing communications links to wiring breaks or shorts as well as inactive network nodes are clearly to guide in returning the system to normal Information are available to provide detail about each specific network node level functions such as timekeeper node and monitor node indicated as well as identification of the node being used for the point service access operator access workstation operator interface provides service level access to information that is not normally public Network private information can be accessed using the Set Host feature and into the database of the network and node of interest With this individual point information can be accessed and controlled required by qualified service personnel with proper password access network connections extensive network expansion or interconnection of existing networks is required up to seven network loops in any of ES Net and 4120 network loops may be connected to TrueSite Workstation Each network loop is connected to its own interface module allowing the workstation to appear as a node each individual loop a multi loop network connection the TrueSite Workstation is a member of each network loop with up to 98 additional nodes per This allows up to 686 total nodes and the TrueSite Workstation 687 total to be interconnected ULC ORD C1076 Proprietary Alarm System Annunciator APOU7 S771 UL 1076 Proprietary Burglar Alarm Multiplex Receiving Unit ULC S559 Central Station Fire Alarm System Receiving Station screens details Over 30,000 custom fields generated and edited graphic screen is available Multiple import and export formats are supported see Formats section in Graphics screens fire alarm network capabilities Multiple workstations can be nodes on the same fire alarm

Related Files