Simplex TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke Heat Detection; Model 4098-9602
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealarm-photoelectric-smoke-detector-with-truesense-smoke-heat-detection-model-4098-9602-2519748063.pdf |
---|---|
Type | |
Size | 618.11 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance detection with TrueSense operation photoelectric detection with heat to provide a multi mode detector with detection mechanisms Stable and reliable photoelectric smoke detection with TrueAlarm sensitivity drift compensation Resettable thermistor based fixed temperature detection Resettable thermistor based rate of rise temperature And TrueSense detection a patented correlation of activity and thermal activity providing intelligent detection earlier than with either activity alone chamber enclosure Louvered design enhances smoke capture by directing Entrance areas are minimally visible when ceiling to chamber normal and alarm conditions Operation is for ceiling or wall mounting LED indicator Provides status during magnetic functional test operated functional test alarm and verifies performance general sensitivity status using detector LED normal more sensitive or less sensitive With detectors categorized as normal or needing or other service maintenance priorities can be easily determined options Bases for 2 wire or 4 wire operation Auxiliary alarm relay output Remote alarm indicating LED for EMI compatibility listed to Standard 268 This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Smoke Detectors TrueAlarm Photoelectric Smoke Detector TrueSense Smoke Heat Detection TrueSense Detector Mounted in Base 4098 9602 detectors combine photoelectric detection technology and quick response heat detection technology into a intelligent detector that analyzes each of activities and their combination to determine alarm conditions are present Detection Modes An onboard microprocessor four independent detection modes photoelectric with TrueAlarm sensitivity drift compensation temperature heat detection rate of rise temperature detection and TrueSense photoelectric heat trending and alarm detection If any of these alarm are experienced an alarm is initiated Current Current 2 Wire Current 4 Wire Relay Ratings Alarm Temperature Alarm Listed Temp Range Temp Range Temp Range Obscuration Velocity Range Range to 32 VDC from Control Panel IDC 24 VDC to 86 mA maximum exact current is by alarm current limiting of IDC initiating device circuit mA typical 24 VDC to page 3 under Product Selection 20 F min 11 C min only in effect temperatures above 90 F 32 C F 57 C F to 100 F 0 C to 38 C F to 100 F 9 C to 38 C to 140 F 18 C to 60 C Nominal per UL268 ft min 0 610 m min to 95 RH from 32 F to 122 F C to 50 C White Dia x 2 H mounted in base mm x 51 mm refer to p 3 for detail Always locate this and all rate of rise heat detection devices away from of temperature fluctuation 1 2015 Electronic Heat Detection Continued Heat Detection occurs at F min C min To minimize the possibility of false alarms detection is correlated to the ambient and is only in effect above 90 F 32 C TrueSense Detection Photoelectric Activity and Thermal TrueSense analysis correlates both thermal and smoke activity at a single multi sensor using an extensively tested covariance As a result TrueSense detection improves to conditions indicative of faster acting hot fires when compared to the response of either smoke activity or thermal activity alone Integrity Detection TrueSense operation early fire detection and maintains the established level of immunity to false alarms and nuisance that is inherent with TrueAlarm sensor operation Notes heat detector location guidelines temperature operating range is 32 F to 100 F C to 38 C Temperature fluctuations should be 6 F min 3.3 C min locations should be determined only after careful of the physical layout and contents of the to be protected Refer to NFPA 72 the National Fire Code On smooth ceilings spacing of 30 ft 9.1 m be used as a guide additional installation information refer to Simplex 574 709 4098 Detectors Sensors and Bases Manual TrueAlarm Smoke Detection Features Data Evaluation Conventional smoke will typically drift toward being too sensitive to the accumulation of dust and dirt With TrueAlarm detection data from the photoelectric chamber is and analyzed at the detector to provide a shifting reference point Compensation The data evaluation and its reference point provide a software filtering that compensates for environmental factors dust etc and component aging establishing an accurate for evaluating new activity With this filtering resulting drift compensation provides a significant in the probability of false or nuisance alarms by shifts in sensitivity either up or down Sensitivity and Dirty Status With its onboard software compensation 4098 9602 maintains its sensitivity much longer in the of dust and dirt accumulation Additionally it determine when the dirt accumulation is approaching limit of compensation and will indicate that condition its status indicator LED see diagnostic information Magnetic Test Information Status information is by performing the magnetic test and observing detector LED pulses The LED will normally go into alarm with the magnetic test If there is an condition the LED pulses first to indicate the and then goes into alarm see page 3 Heat Detection Temperature Heat Detection is provided with addition of a fast response thermistor that causes an at a fixed temperature of 135 F 57 C Dimensions and Reference Information 6.4 mm Adapter Plate 162 mm 124 mm 51 mm Remote Red Alarm Indicator to scale Indicator LED guard Dimensions Mounted on Base 1 2015 Height 17 mm base 4098 9602 Product Selection Detector photoelectric detector with photoelectric thermal detection with bases 4098 9788 4098 9682 and 4098 9683 Bases Base with connections for Remote LED Indicator Base with Auxiliary Alarm Relay and connections for Remote LED Indicator Requires external 24 VDC for Base with Auxiliary Alarm Relay connections for Remote LED Indicator Must be connected as the only device the IDC to ensure relay operation Accessories Plate LED Indicator Mounted VDC Relay and LED connections are screw terminals for in out wiring to 14 AWG Ratings Single Form For Suppressed Loads limited 3 A 28 VDC Non power limited 3 A 120 VAC Connections In Out where required contacts and IDC wiring color coded 18 AWG leads wiring screw ter