Simplex TrueAlarm Photoelectric Smoke Detectors for Two-Wire and Four-Wire Bases

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Smoke Detectors TrueAlarm Photoelectric Smoke Detectors Two Wire and Four Wire Bases smoke detector with on board sensitivity drift compensation chamber enclosure Louvered design enhances smoke capture by directing Entrance areas are minimally visible when ceiling to chamber Operation is for ceiling or wall mounting indicator LED indicates normal alarm conditions operated functional test alarm and verifies performance general sensitivity status using detector LED available in two sensitivity settings 4098 9601 Standard Sensitivity nominal 2.8 ft 4098 9605 Special Application Sensitivity nominal obscuration options Bases for 2 wire or 4 wire operation Auxiliary alarm relay output Remote alarm indicating LED for EMI compatibility listed to Standard 268 TrueAlarm photoelectric detectors many of the proven TrueAlarm analog sensing for applications where detectors are connected to 2 wire or 4 wire initiating device circuits Each TrueAlarm detector has an on board that evaluates its photoelectric light chamber activity and makes an intelligent based on light obscuration history as to whether alarm condition is present detectors are packaged in a patented that minimizes the visibility of the air intake from the normal viewing locations while a high performance smoke capture ability are available for remote alarm LED indicator and auxiliary relay outputs TrueAlarm Photoelectric Mounted in Base Current Current 2 Wire to 32 VDC from Fire Alarm Panel IDC 24 VDC to 86 mA maximum exact is determined by alarm limiting of connected IDC mA typical 24 VDC ft min 0 610 m min Current 4 Wire Relay Ratings Refer to page 2 under Product Velocity Range Listed Temp Range 32 to 100 F 0 to 38 C Temp Range 15 to 122 F 9 to 50 C to 140 F 18 C to 60 C Temp Range to 95 RH from 32 to 122 0 to 50 C non condensing White Dia x 1 7 8 H mounted in 124 mm x 48 mm refer to 3 for detail Range ULC listed model is 4098 9601 This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7272 0026 219 for allowable values and or conditions concerning presented in this document Accepted for use City of New York Department of MEA35 93E Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Fire Protection Products 1 2015 Sensitivity Photoelectric Detector with bases 4098 9788 and 4098 9683 TrueAlarm Smoke Detector Features Data Evaluation Conventional smoke will typically drift toward being too sensitive to the accumulation of dust and dirt With TrueAlarm detection data from the photoelectric chamber is and analyzed at the detector to provide a shifting reference point Compensation The data evaluation and its reference point provide a software filtering that compensates for environmental factors dust etc and component aging establishing an accurate for evaluating new activity With this filtering resulting drift compensation provides a significant in the probability of false or nuisance alarms by shifts in sensitivity either up or down Test Information Status information is by performing the magnetic test and observing detector LED pulses The LED will normally go into alarm with the magnetic test If there is an condition the LED pulses first to indicate the and then goes into alarm See page 3 Product Selection Detectors 2.8 ft standard 3.5 ft special application sensitivity ULC listed Bases 2 Wire Base with connections for Alarm LED Indicator Base with Auxiliary Alarm Contacts and connections for LED Alarm Indicator Requires external 24 VDC for Base with Auxiliary Alarm connections for Remote LED Must be connected as the only on the IDC to ensure relay Accessories Adapter Plate Remote LED Indicator Encapsulated Plate Mounted VDC Relay Application Reference Locations Locations should be determined after careful consideration of the physical layout and of the area to be protected Refer to NFPA 72 National Fire Alarm Code On smooth ceilings detector spacing of 30 ft 9.1 m may be used as a For detailed installation information refer to 4098 Sensors and Bases Application Manual Selection The 4098 9601 standard detector is recommended for most applications a special application for a reduced sensitivity is required the 4098 9605 should be considered your local Simplex product supplier for in determining the proper selection and LED connections are screw terminals for in out wiring to 14 AWG Ratings Single Form For Suppressed Loads limited 3 A 28 VDC Non power limited 3 A 120 VAC Connections In Out where required contacts and IDC wiring color coded 18 AWG leads wiring screw terminals for 18 to 14 AWG Ratings Dual Form For Suppressed Loads limited 1 A 28 VDC Non power limited 1 2 A 120 VAC Connections In Out where required contacts and IDC color coded 18 AWG leads and LED wiring screw terminals for 18 to 14 AWG for mounting to surface mounted 4 102 mm square or octagonal boxes and to 4 square flush mounted boxes be used when retrofitting existing bases with detector bases 4098 9788 9682 9683 on single gang stainless steel plate 2 1 2 x 1 1 2 x 1 mm x 38 mm x 25.4 mm on single gang steel plate for 4 wire circuits using base one per circuit select type as required wiring is color 18 AWG wire leads Refer to pages 3 and 4 for dimensions and additional mounting details 18 AWG 0.82 mm2 14 AWG 2.08 mm2 1 2015 Detector Status LED Indications approximately every 4 seconds Indication On Response to Magnetic Test Indication turns ON pulses quickly times in 3 seconds turns ON pulses slowly times in 8 seconds turns ON By is initiated is initiated is initiated not initiate Alarm Dimensions and Reference Information mm sensitivity is within range sensitive out of normal range sensitive out of normal range is malfunctioning or other is required is required Testing requires placing a magnet at the designated location on the detector cover for 4 seconds Refer to Application Manual 574 709 for test and maintenance information 162 mm Adapter Plate 124 mm height mm mm Status Indicator clear lens 9605 Dimensions Mounted on Base 4098 9830 Remote LED Indicator not to scale 1 2015 Mounting Information boxes are supplied by others Box Requirements relay base 4098 9788 octagonal or 4 square 1 1 2 deep gang 2 deep relay bases 4098 9682 and 4098 9683 octagonal 1 1 2 deep with 1 1 2 extension ring square 1 1 2 deep with 1 1

Related Files