Simplex TrueAlert Addressable Controller Main Board Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-controller-main-board-installation-instructions-7102964835.pdf |
---|---|
Type | |
Size | 958.20 KB |
Downloads |
Text Preview
Cautions and Warnings Addressable Controller Board Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking Simplex product inspect the contents of the carton for shipping damage If damage is apparent file a claim with the carrier and notify Simplex Hazard Disconnect electrical power when making any internal adjustments or repairs should be performed by qualified Simplex Representatives HAZARD Static electricity can damage components Therefore handle as follows Ground yourself before opening or installing components use the 553 484 Static Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual may cause interference to communications It has been tested and found to comply with the limits for a Class A computing pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable against such interference when operated in a commercial environment Operation of this in a residential area is likely to cause interference in which case the user at his own expense be required to take whatever measures may be required to correct the interference publication shows how to install the TrueAlert Main Board Part No 565 990 into a TrueAlert Addressable Controller 4009 to the TrueAlert Addressable Controller Installation Guide 574 762 for configuration information the 4009 TrueAlert Controller Wiring Diagram 842 158 for additional wiring information and the Basic Configuration Wiring and Trouble Shooting 526 852 located on the inside of the 4009 door assembly Board Configuration 4009 configuration address settings are set by TrueAlert Main Board DIP Switches SW1 SW2 SW3 NAC Address Switches SW4 Configuration and SW5 Software Address Software The replacement TrueAlert Main Board DIP switch s SW1 SW2 SW4 and SW5 must be set identical to the configuration its replacing Make a note of current settings on the installed TrueAlert Board to be replaced and refer to the 4009 TrueAlert Addressable Controller Installation Instructions 574 762 and located on the of the 4009 door assembly the 4009 Basic Configuration Wiring and Trouble Shooting Procedures 526 852 Notes for removing the TrueAlert Main Board to Figure 1 and the 4009 TrueAlert Controller Field Wiring Diagram 842 158 Using a Key unlock and open the door assembly on the 4009 Disconnect the 4009 Batteries Remove AC Power from the 4009 at the breaker Field Wiring may remain attached to the option cards Mark and remove all field wiring internal wiring and option cards connected to the 4009 main board Remove four torx screws securing the Main Board to the mounting plate Using gentle pressure remove the Main Board from the two that hold the board in place 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice and IDNet are trademarks of Simplex Time Recorder Company A Notes for installing the TrueAlert Main Board to Figure 1 and the 4009 TrueAlert Controller Field Wiring Diagram 842 158 all removed field wiring internal wiring and option cards and connect them to the replacement Main Board the main board to the snaps ins and secure the board to the mounting plate using four torx screws Connect AC Power Connect the 4009 Batteries Test the 4009 for proper Alarm and Trouble operation and configuration before locking the door SLC Channels TB4 TB5 1 3 Control Interface TB1 Note 2 Control Interface TB2 Note 2 Configuration Switch SW4 Switch SW5 Note 4 Screws 4 Card Note 4 Address SW1 SW3 Note 3 2 Power TB6 Notes 5 Control TB7 Note 2 TRUEALERT BOARD H2 BLK YEL Repeater Card or Receiver Card Cards Note 4 Charger Inputs Wire P5 Wire P6 Note 5 Input TB8 Note 5 Rectifier Inputs Wire to Positive Terminal H1 of Bridge Wire to Negative Terminal H2 of Bridge Note 5 Refer to the 4009 TrueAlert Controller Field Wiring Diagram 842 158 for additional wiring information 4009 provide NAC Control via the RUI Control Interface TB1 IDNet Control Interface TB2 or the NAC Control Interface TB7 one of these three interfaces will have field wiring connected to its terminals For detailed information on NAC Address Switches SW1 SW2 SW3 Hardware Configuration Switch SW4 and Software Address Software SW5 refer to the 4009 TrueAlert Addressable Controller Installation Instructions 574 762 and located on the inside of the 4009 door the 4009 TrueAlert Addressable Controller Basic Configuration Wiring and Trouble Shooting Procedures 526 852 necessary refer to the following installation instructions for the 4009 option cards Class A Adapter Installation Instructions 574 763 Optic Link Installation Instructions 574 182 Repeater Card Installation Instructions 574 327 Maintain correct polarity on these connections 1 4009 TrueAlert Main Board Connections A