Simplex TrueAlert Addressable Notification Appliances; Dual Emergency Communication Appliances, Clear Amber Strobe; S4906-0009
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-notification-appliances-dual-emergency-communication-appliances-clear-amber-strobe-s4906-0009-5913867042.pdf |
---|---|
Type | |
Size | 844.07 KB |
Downloads |
Text Preview
ULC CSFM Listed Addressable Notification Appliances Dual Emergency Communication Clear Amber Strobes Individually addressed and separately controlled V O visible only notification with one amber ALERT strobe and one lens FIRE strobe provides Combination unit allows mounting two visible appliances at the same installation site Multi candela xenon strobes with synchronized 1 Hz rate and with intensity programmable from the panel or jumper selected as 15 30 75 or cd Advanced addressable notification controlled by IDNAC from Simplex 4100ES fire alarm control panels EPS EPS power supplies and 4009 IDNAC providing regulated 29 VRMS allowing to operate with lower current even under backup Amber lens with lettering produces a signal from clear lens fire alarm evacuation strobes for with Emergency Communications Systems Clear lens with lettering provides visible for fire alarm conditions Both strobes connect on same SLC are separately and provide independent operation is clear Fire OR amber Alert not both Wiring supervision to each strobe allowing connections for Class B circuits to wiring Class A circuits require in out TrueAlert Device Reports at the control panel appliance point ID custom label type and setting see sample on page 2 Magnet test diagnostics to assist checkout and testing appliances and wiring Compatibility with ADA requirements refer to installation information on page 3 Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 4 Clear lens strobe is UL listed to Standard 1971 ULC to Standard S526 Amber lens strobe is UL listed to Standard 1638 due to lens and provides light dispersion patterns of Standard 1971 ULC listing is to Standard S526 indicator and magnet test feature Each appliance LED can be selected to display each cycle to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe is also to confirm operation This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7125 0026 235 allowable values and or conditions concerning material presented in this document FM and MEA NYC acceptance is not applicable Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals under Time Recorder Co are the property of Tyco Safety Products Westminster Clear Amber Strobe Assembly front and view shown available with red or white housing design features Rugged high impact flame retardant thermoplastic for flush or surface wall mount available red or white housing strobe housings mount onto a common that does not extend into box and easily to standard electrical boxes Wall mount wiring terminal access is from front of to assist installation inspection and testing Mounting options include adapter skirts for surface and box adapter plates Multi Candela TrueAlert addressable combination are individually addressed and individually with power supervision and control supplied a Simplex fire alarm control panel providing IDNAC Line Circuits SLCs See compatibility list on 4 A single assembly provides an amber lens strobe for alarm alert notification for use with Emergency Systems and a clear lens strobe for fire notification Application Reference Amber strobes used as part of an Emergency system are located to provide the same coverage as required of clear lens fire alarm strobes Emergency Communications requirements are in detail in document UFC 4 021 01 USA of Defense United Facilities Criteria and in 72 Chapter 24 2010 and 2013 editions strobe coverage criteria is further described in the Fire Alarm Code NFPA 72 ANSI A117.1 the model building code BOCA ICBO or SBCCI the application guidelines of the Americans with Act ADA 3 2014 IDNAC SLC Operation Advantage V O Appliances with Addressable on IDNAC SLCs provide visible notification a single two wire circuit that also confirms to the individual notification appliance circuit This operation increases circuit integrity by providing supervision that beyond the appliance wiring connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VRMS voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up to to 3 times farther than with conventional notification or for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits all installation and maintenance savings with high that appliances that operate during normal system will operate during worst case alarm conditions Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of the magnet test feature installation efficiency TrueAlert device reports identify information about each connected providing an amber lens strobe with a clear lens the combination strobe assembly allows a single installation to provide both types of visible Product Selection TrueAlert Addressable Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll When controller is selected for diagnostic mode the appliance test feature provides a response at the individual being tested Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance Appliance Testing In this test mode after address is indicated by pulsing the appliance LED the will briefly flash to indicate proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring Refer to data S4905 0001 for additional information Device Reports detail type candela rating location per appliance see sample below amber lens is AMB Addressable Combination Strobe assembly with lens ALERT strobe on top and clear lens FIRE strobe bottom intensity selectable as 15 30 75 or 110 candela Mount Adapter Skirt use to cover surface mounted boxes Plate for mounting to installed Simplex Model box for flush mounted boxes only H x 5 W x 3 15 D mm x 130 mm x 100 mm H x 5 W x 1 D mm x 133 mm x 44 mm depth with strobe assembly 5 143 mm 5 H x 5 W x 0.06 thick mm x 146 mm x 1.5 mm TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Fire Room Alert 1 MON 17 Mar 14