Simplex TrueAlert Addressable Notification Appliances Multi-Candela Audible Visible (A V) Appliances; CeilingMount

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Appliances Multi Candela Audible Visible Appliances Ceiling Mount Individually addressed and controlled A V audible visible notification provide Multi candela xenon strobe with synchronized 1 Hz rate and with intensity programmable from the panel or jumper selected as 15 30 75 or cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each strobe allowing for Class B circuits to simplify wiring A circuits require in out wiring TrueAlert Device Reports at the control panel appliance point ID custom label type and setting see sample on page 2 Magnet test diagnostics to assist checkout and testing appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 4 Strobe operation listed to UL Standard 1971 and ULC S526 S525 Horn operation listed to UL Standard 464 and ULC indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe and the is also selectable to confirm operation design features Rugged high impact flame retardant thermoplastic are available in red or white Rear of housing does not extend into box and easily to standard electrical boxes Mounting options include red wire guards and for surface mount electrical boxes notification appliance horn Low current electronic horn with harmonically rich sound for either coded or steady operation Horns sound as Temporal or March Time pattern or 120 BPM or on continuously controlled from visible appliances on the same circuit Output is or 5 dBA difference SLC control selects output per device Mount Addressable A Vs Multi Candela TrueAlert addressable A Vs provide installation to standard electrical boxes is individually addressed and individually with power supervision and control supplied a Simplex fire alarm control panel providing IDNAC Line Circuits SLCs See compatibility list on 3 Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm and Signaling Code 72 ANSI A117.1 the appropriate model building BOCA ICBO or SBCCI and the application of the Americans with Disabilities Act ADA SLC Operation Advantage A V Addressable Appliances on IDNAC provide audible and visible notification using a two wire circuit that also confirms connection to individual notification appliance electronic circuit operation increases circuit supervision integrity by supervision that extends beyond the appliance connections See page 2 for wire guard listings This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7125 0026 239 for allowable values and or conditions concerning presented in this document Accepted for use City of New York Department of MEA35 93E Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster 2 2015 IDNAC SLC Operation Advantage Cont current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of the magnet test feature installation efficiency TrueAlert device reports identify information about each connected Product Selection TrueAlert Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate circuited wiring from functioning wiring Refer to sheet S4905 0001 for additional information Addressable Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll the controller is selected for diagnostic mode the magnet test feature provides a response at the appliance being tested Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance Appliance Testing In this test mode the address is indicated by pulsing the appliance the strobe will briefly flash and the horn will briefly to indicate proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information Ceiling Mount Addressable A Vs Guards and Ceiling Mount A V Adapter Horn with Multi Candela Strobe selectable as 15 30 75 or 110 Red Wire Guard for mounting to flush mounted electrical box Red Adapter Plate required for surface mount guard White Surface Mount Adapter Box Extension use to cover 1 1 2 Red UL listed by Space Age Electronics Inc surface mounted boxes L x 6 W x 2 D mm x 175 mm x 67 mm x 6 x 3 mm x 156 mm x 76 mm x 7 229 mm x 178 mm x 6 x 1 deep 121 mm x 175 mm x 38 mm TrueAlert Device Reports Reference Port 5 TrueAlert Device Report ID LABEL Label up to 40 characters Room 5 Room Room 7 1 TUE 27 Jan 15 2 2015 Ceiling Mount A V and Guard Installation Reference 102 mm box 38 mm depth reference mounted box 4905 9915 white or 4905 9916 red recommended for surface mounted box reference mounted box terminals and address setting located behind the housing 4905 9927 Wire Guard 4905 9928 Plate required surface mounted box mounting clamps two each side test area View intensity viewing slot selection plug only from rear of housing factory setting is controlled by panel indicator housing straight on view IDNAC SLC Controller Compatibility Reference Controllers Sheet with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply S4010 0011

Related Files