Simplex TrueAlert Addressable Notification Appliances, Multi-Candela Speaker Visible (S V) Appliances

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM MEA NYC addressed and controlled multi candela S V notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control unit or jumper selected as 15 30 cd 75 cd or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each strobe allowing T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring TrueAlert Device Reports at the control unit detailing appliance point ID label type and candela setting see sample on page 2 Magnet test diagnostics to assist checkout and testing of appliances Compatibility with ADA requirements refer to Wall mount installation wiring Compatibility with legacy TrueAlert addressable systems for upgrade replacement see TrueAlert strobe LEGACY compatibility reference Strobe operation is listed to UL 1971 and ULC S526 indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate supervision In diagnostic mode the magnet test pulses the LED to indicate address and pulses to indicate the intensity selection a brief of the strobe is also selectable to confirm operation design features Rugged high impact flame retardant thermoplastic housings are for wall or ceiling mount Wall mount housings are available in red or white Wall mount options include electrical box adapters separate covers to color and red wire guards Ceiling mount housing is white notification appliance speaker High quality voice and tone reproduction with taps for 1 4 W 1 2 W 1 or 2 W at 25 VRMS or 70.7 VRMS Speakers have capacitor input for connection to DC supervised NACs are wired separately from strobes Listed to UL 1480 and ULC S541 Compliant with NFPA 72 520 Hz Low Frequency Signal Requirements Sleeping Areas Addressable Notification Appliances Speaker Visible S V Appliances 1 and ceiling mount SVs with addressable strobes TrueAlert S Vs with speaker and addressable TrueAlert S Vs provides convenient installation to electrical boxes with extensions The strobe is individually and individually controlled with power supervision and supplied from Simplex fire alarm control units providing IDNAC Line Circuits SLCs See TrueAlert strobe LEGACY compatibility for additional information Speakers are wired separately application reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the application guidelines of Americans with Disabilities Act ADA Rev 9 3 2020 Speaker Visible S V Appliances SLC operation advantage S V appliances with addressable strobes on IDNAC SLCs provide visible notification using a single two wire circuit that also confirms to the individual notification appliance s electronic circuit This operation increases circuit supervision integrity by providing supervision that beyond the appliance wiring connections current allows efficient IDNAC SLC operation With IDNAC SLCs a constant 29 VDC source voltage is maintained even during battery allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both power and secondary battery standby Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification support for more appliances for each IDNAC SLC or use of smaller gauge wiring or combinations of these benefits all providing installation and savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions installation and testing time With separate controls on the same two wire SLC installation time and expense for both retrofit and new can be significantly reduced When Class B wiring is used wiring can be T tapped allowing more savings in distance wire conduit size utilization and overall installation efficiency Use of the magnet test feature improves installation efficiency TrueAlert device reports conveniently information about each connected appliance addressable wiring isolator Model 4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring to data sheet S4905 0001 for additional information addressable diagnostics Features The operator can select controllers to pulse each appliance s LED when it receives a supervision poll When the operator selects a for diagnostic mode the appliance magnet test feature provides a response at the individual appliance being tested Appliance Magnet Test In this test mode in response to the magnet test the appliance LED pulses sequentially to conveniently indicate the address Appliance Testing In this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash to indicate operation Instrument Two TSIT The second generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert TrueAlert ES appliances to its ability to test IDCs NACs and IDNet communications before connection to the control unit Please contact your local representative for additional information selection 1 Multi Candela addressable S Vs and ULC FIRE FIRE FIRE ALERT FIRE 1 4 in H x 5 in W x 2 5 8 in D 184 mm x 127 mm x 67 mm 1 2 in or 191 mm diameter speaker housing in or 13 mm deep lens extends 2 5 8 in or mm above housing extension into box 2 3 4 or 70 mm with Strobe selectable 15 30 75 or 110 2 Wall mount S V adapters replacement covers wire guard ceiling mount tile bridge mount red adapter skirt mount white adapter skirt when mounting to surface electrical box 4 in square 1 2 in deep with 1 1 2 in deep plate red required to mount S V on 2975 9145 mounting box for retrofit box red for surface or flush mount requires adapter plate This box may be available for retrofit applications wall mount S V replacement cover with white FIRE lettering wall mount S V replacement cover with red FIRE lettering wire guard for wall mount S V with mounting plate compatible with and semi flush boxes UL listed by Space Age Electronics Inc bridge for ceiling mount S Vs 3 4 in H x 5 3 8 in W x 3 3 16 in D or 197 mm x 137 x 81 mm depth with S V 5 7 8 in or 149 mm 5 16 in H x 5 3 4 in W x 0.060 in Thick 211 mm x 146 mm x 1.5 mm 7 8 in H x 5 1 8 in W x 2 3 4 in D 200 mm x 130 mm x 70 mm 1 4 in H x 5 in W x 1 3 8 in D 184 mm x 127 mm x 35 mm 3 8 in H x 6 1 16 in W x 3 1 4 in D 213 mm x 154 mm x 79 mm Ceiling mount S V install reference and tile bridge 2 Rev 9 3 2020 device reports reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 mount installation reference Speaker Visible S V Appliances 1 TUE 27 Jan 14 TYPE 3 Rev 9 3 2020 mount S V install reference and tile bridge dimensions Speaker Visible S V Appliances SLC controller compatibility reference 3 IDNAC SLC controller compatibility reference controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply sheet output SLC output voltage reference SLC VDC regulated VDC 6 VDC drop specifications instructions voltage taps response 4 Common specifications

Related Files