Simplex TrueAlert Addressable Notification Appliances; Multi-Candela Speaker Visible (S V) Appliances, Chinese English
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-notification-appliances-multi-candela-speaker-visible-s-v-appliances-chinese-english-4968250173.pdf |
---|---|
Type | |
Size | 886.81 KB |
Downloads |
Text Preview
UL Listed Addressable Notification Appliances Multi Candela Speaker Visible Appliances Chinese English Individually addressed and controlled S V speaker visible notification provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected as 15 30 75 or 110 cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each strobe allowing connections for Class B circuits to wiring Class A circuits require in out TrueAlert Device Reports at the control panel appliance point ID custom label type and setting see sample on page 2 Magnet test diagnostics to assist checkout and testing appliances and wiring Compatibility with ADA requirements refer to installation information on page 3 Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 4 Strobe operation is listed to UL 1971 indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe is also to confirm operation design features Rugged high impact flame retardant thermoplastic are available for wall or ceiling mount Wall mount housings are white Wall mount options include electrical box adapters cover and red wire guards Ceiling mount housing is white notification appliance speaker High quality voice and tone reproduction with taps for 1 or 2 W at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC NACs and are wired separately from strobes Listed to UL 1480 Compliant with NFPA 72 520 Hz Low Frequency Requirements for Sleeping Areas See page 2 for additional listing details and wire guard listings Additional listings may applicable contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection and Ceiling Mount S Vs with Addressable Strobes mount S V shown with cover 4905 9848 Multi Candela TrueAlert S Vs with speaker and strobe provide convenient installation to electrical boxes with extensions The strobe is addressed and individually controlled with supervision and control supplied from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 are wired separately Application Reference Proper selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm and Signaling Code 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the guidelines of the Americans with Disabilities ADA SLC Operation Advantage S V Appliances with Addressable on IDNAC SLCs provide visible notification a single two wire circuit that also confirms to the individual notification appliance circuit This operation increases circuit integrity by providing supervision that beyond the appliance wiring connections 2 2015 IDNAC SLC Operation Advantage Cont current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of the magnet test feature installation efficiency TrueAlert device reports identify information about each connected Product Selection Addressable S Vs TrueAlert Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate circuited wiring from functioning wiring Refer to sheet S4905 0001 for additional information Addressable Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll When controller is selected for diagnostic mode the appliance test feature provides a response at the individual being tested Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance Appliance Testing In this test mode after address is indicated by pulsing the appliance LED the will briefly flash to indicate proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information FIRE H x 5 W x 2 D mm x 127 mm x 67 mm 191 mm diameter speaker housing 13 mm deep lens extends 2 67 mm housing into box 2 70 mm Note Replace cover with replacement cover 4905 9848 per below for Chinese English Covers Wall Mount S V Adapters Skirt Wire Guard and Ceiling Mount Tile Bridge ALARM Speaker Multi Candela Strobe selectable as 30 75 or 110 Chinese English White Wall Mount S V Cover with red ALARM see note above Surface Mount White Adapter Skirt required when mounting to surface mounted box 4 square 1 deep with 1 deep extension Red Wire Guard for Wall Mount S V with mounting plate compatible with surface semi flush boxes UL listed by Space Age Electronics Inc Tile Bridge for Ceiling Mount S Vs H x 5 W x 1 D mm x 127 mm x 35 mm H x 5 W x 3 3 D mm x 137 mm x 81 mm with S V 5 149 mm H x 6 1 W x 3 D mm x 154 mm x 79 mm diagram on page 3 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report ID LABEL Label up to 40 characters Room 5 Room Room 7 1 TUE 27 Jan 15 2 2015 Wall Mount Installation Reference Ceiling Mount S V Install Reference and Tile Bridge Dimensions 102 mm square 1 1 2 38 mm deep with 1 1 2 extension by others input and tap are from of speaker test location indicator view DIPswitch is behind strobe assembly address before inserting into housing i