Simplex TrueAlert Addressable Notification Appliances; Multi-Candela Visible Only (V O) Appliances (Strobes), Ceiling Mount

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Appliances Multi Candela Visible Only V O Strobes Ceiling Mount Individually addressed and controlled V O visible only notification provide Multi candela xenon strobe with synchronized 1 Hz rate and with intensity programmable from the panel or jumper selected as 15 30 75 or cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each strobe allowing connections for Class B circuits to wiring Class A circuits require in out TrueAlert Device Reports at the control panel appliance point ID custom label type and setting see sample on page 2 Magnet test diagnostics to assist checkout and testing appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 3 UL listed to Standard 1971 and ULC S526 indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe is also to confirm operation design features Rugged high impact flame retardant ceiling mount housings are available in red or white Rear of housing does not extend into box and easily to standard electrical boxes Mounting options include red wire guards and for surface mounted electrical boxes See page 2 for wire guard listings This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7125 0026 235 for allowable values and or conditions concerning presented in this document Accepted for use City of New York Department of MEA35 93E Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster Mount Addressable V Os Multi Candela TrueAlert addressable strobes convenient installation to standard electrical The strobe is individually addressed and controlled with power supervision and supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuits SLCs See list on page 3 Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm and Signaling Code 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the guidelines of the Americans with Disabilities ADA SLC Operation Advantage addressable appliances on IDNAC SLCs separate visible and audible notification using a two wire circuit that also confirms connection to the notification appliance electronic circuit This increases circuit supervision integrity by providing that extends beyond the appliance wiring current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm 2 2015 IDNAC SLC Operation Advantage Cont Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of the magnet test feature installation efficiency TrueAlert device reports identify information about each connected Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate circuited wiring from functioning wiring Refer to sheet S4905 0001 for additional information TrueAlert Addressable Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll the controller is selected for diagnostic mode the magnet test feature provides a response at the appliance being tested Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance Appliance Testing In this test mode the address is indicated by pulsing the appliance the strobe will briefly flash to indicate proper Instrument Two TSIT The 2nd of the Simplex TrueStart Test Instrument adds of IDNAC SLC wiring and TrueAlert and ES appliances to its ability to test IDCs and IDNet communications before connection to control panel Please contact your local Simplex for additional information Product Selection Ceiling Mount Addressable Strobe Lettering x 2 5 x 2 D mm x 75 mm x 67 mm Addressable Strobe selectable as 15 30 75 or candela Adapters see diagram on page 3 Mount Surface Mount Adapter Plate zinc plated required for surface mount x 3 124 mm x 79 mm Guards see diagram on page 3 Ceiling Mount Red wire guard with mounting plate compatible with or surface mounted boxes UL listed by Space Age Electronics Inc x 4 x 2 mm x 111 mm x 73 mm TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 1 TUE 27 Jan 15 2 2015 Ceiling Mount V O and Guard Installation Reference gang box Wiremold V5744S 57 mm deep supplied by others setting DIPswitch is behind strobe select address and strobe setting before inserting into housing view location indicator IDNAC SLC Controller Compatibility Reference Controllers Sheet with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply S4010 0011 Specifications box 1 1 2 38 mm deep RACO 650 or or single gang box 2 1 2 64 mm deep 519 or equal supplied by others can be attached to boxes mounted to drop T bar with clips ERICO No 512 or equal Adapter Plate required for surface with handy box unless using the 4905 9926 guard mount strobe 4905 9926 wire with mounting plate intensity viewing slot selection plug only from rear of lens factory setting is FACP by panel Output SLC Output Voltage Reference SLC VDC VDC 6 VDC drop Specifications see page 2 for dimensions Instructions Specifications Operating Voltage Range Requirements Rate and Synchronized SLC Loading VDC RMS Current Ratings for connection to Addressable SLCs

Related Files