Simplex TrueAlert Addressable Notification Appliances; TrueAlert Addressable Adapter Modules; S4905-0004
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-notification-appliances-truealert-addressable-adapter-modules-s4905-0004-8479321056.pdf |
---|---|
Type | |
Size | 847.11 KB |
Downloads |
Text Preview
Datasheet Addressable Notification Appliances Addressable Adapter Module Model 4905 9816 additional information refer to 4905 9816 4906 TrueAlert Adapter Instructions 579 390 1 TrueAlert Addressable Adapter Typical One Line Wiring Reference Wiring Details with circuit protectors When connected to remote up to 200 ft from the adapter that exit the building and may exposed to harsh electrical environments the notification appliance is compatible with Simplex circuit protectors Compatible are listed in Specifications Connect both where the wiring the building and where it connects to the appliances for shielded wire For applications where notification wiring may be exposed to electrical noise twisted shielded is recommended The adapter wiring terminal block has for connecting the shields CSFM Listed FM Approved MEA Acceptance a single TrueAlert addressable notification address into 24 VDC audible and visible notification outputs Power and communications are supplied by Simplex 4100ES 4010ES 4007ES fire alarm control panels equipped with power supplies provide advanced addressable notification from IDNAC Signaling Circuits SLCs and from 4009 IDNAC Repeaters Operation is also compatible with TrueAlert SLCs from TrueAlert Power TPS or TrueAlert Addressable Controllers 4009T You can connect up to two TrueAlert Addressable Adapter Modules to IDNAC SLC control output features Operation modes are visible and audible appliances both on or visible only with activation determined by the control panel IDNAC On board circuit limits appliance inrush current and provides self overcurrent protection Wiring to audible and visible appliances is supervised with conventional polarity operation opens or shorts are reported to the control output ratings Regulated 24 DC appliance power audible output is rated for up to 30 visible output is rated for up to 180 mA Special Applications appliance ratings audible output is rated for up to mA visible output is rated for up to 250 mA diagnostics You can program a visible status LED at the connected control panel indicate polling status and can be activated for each address for testing mechanical features Mounts in standard 4 11 16 in 119 mm square electrical box Cover plates required are available for surface or flush mount separately Cover plates provide status LED viewing Screw terminals for wiring connections listed to Standard 864 Notification Requirements IDNAC SLCs activate addressable horns or strobes in response to commands received from IDNAC SLC For applications where appliances other than the TrueAlert addressable appliances are required the TrueAlert Adapter Module provides a separate audible and visible individually activated by the IDNAC SLC applications are for connection to special weather proof appliances with particular sound output characteristics bells or chimes or for connection to appliances that are required satisfy specific aesthetic requirements TrueAlert Addressable System Advantages With the Addressable Adapter Module you can control non TrueAlert while still benefiting from the TrueAlert addressable system s supervision to the Adapter Module multiple diagnostic modes supporting of T tapped Class B wiring of the IDNAC SLC connections S4905 0004 Rev 7 8 2021 Addressable Adapter Module Model 4905 9816 Addressable Adapter Product Selection 1 Product Selection Addressable Adapter Module requires surface or flush mount cover plate Resistor Harness ref 733 894 10 k 1 2 W two required one each for audible and visible output Mount Cover Plate Mount Cover Plate select one for each 4905 9816 for each application painted beige Addressable Adapter Installation Reference 2 TrueAlert Addressable Adapter Installation Reference 2 S4905 0004 Rev 7 8 2021 Voltage SLCs TrueAlert SLCs Current Requirements Voltage NAC Current Ratings Addressable Adapter Module Model 4905 9816 2 Electrical and Operation Reference VDC and power are supplied from SLC unit load 1 unit load 0.8 mA control panel current mA maximum adapter and appliances Address for each Adapter Module limited to two Adapter Modules for each SLC TO 32 VDC appliance inrush currnet is internally limited to 550mA 24 DC Power Ratings Application Appliance Ratings Output 30 mA Output 180mA Output 50mA Output 250mA Output with Simplex horns and with the horn 4 wire horn strobes A V and 4 wire speakers S V select output as sync mode Speaker circuits require serparate wiring with Simplex strobes and with the of 4 wire horn strobes A V and 4 wire S V select output as sync Speaker circuits require separate wiring Output Mode Control Output Mode Control with Special Application Simplex free run for Simplex strobe synch pulses synchornised to the SLC for continuous on or to follow same pattern as the SLC select continuous if appliance has its pattern selection or if it has high repetitve inrush current Output 3 IDNAC SLC Channel Loading Reference Addressable Adapter Modules for each SLC addresses unit loading SLC Strobe Loading to 46 addressable synchronized strobes maximum for each TrueAlert SLC refer to individual appliance and control panel information for information maximum maximum maximum to 63 addressable synchronized strobes maximum for each IDNAC SLC Current Rating Reference Distance from TrueAlert Addressable Adapter Resistor Connections Circuit Protection required when wiring leaves the building for appliances mount one at each end of wiring Instructions mounted in bracket see Figure 2 Plate Material Range Range EPS Power Supply and 4009 IDNAC Repeater 3 A maximum Power Supply 3 A maximum Addressable Controller 2.5 A maximum 4 Wiring Reference ft maximum 61 m k 1 2 W two required one located at each remote appliance use End of Line Resistor Harness ref 733 894 ordered separately terminals for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 Overvoltage Protector 200 mA maximum Isolated Loop Circuit Protector 5 A maximum Isolated Loop Circuit Protector 200 mA maximum 11 16 in H x 5 in W x 1 9 32 in D 119 mm x 127 mm x 33 mm metal galvanized to 120 F 0 to 49 C adapter is intended to be mounted indoors to 90 RH non condensing at 90 F 32 C 5 Mechanical and Environmental 3 S4905 0004 Rev 7 8 2021 Addressable Adapter Module Model 4905 9816 with EPS with ESS with IDNAC SLCs IDNAC Repeater 6 Panel Data Sheet Reference 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 7 8 2021