Simplex TrueAlert Addressable Notification Appliances; Wall Mount Visible & Audible Visible Notification, Appliances for Emergency Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-notification-appliances-wall-mount-visible-audible-visible-notification-appliances-for-emergency-communications-8960732145.pdf |
---|---|
Type | |
Size | 1.27 MB |
Downloads |
Text Preview
ULC CSFM Listed Approved Addressable Notification Appliances Mount Visible Audible Visible Notification for Emergency Communications Individually addressed and controlled multi candela ES Emergency Communications provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected Standard strobe models with amber lens covers available ALERT lettering or blank and with red or white available with 15 30 75 110 or 135 cd output Separate lens covers are available in amber blue green red to configure strobes V O or audible visible A V see ordering details on page 2 and candela on page 4 Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Emergency Communications appliances are controlled from fire alarm appliances but both can be on same IDNAC SLC only one type activates at a time fire alarm or notification not both Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring TrueAlert ES product features Self Test Mode using on board sensors TrueAlert Device Reports at the control panel Magnet Test diagnostics to assist checkout and test Compatibility with ADA requirements see page 3 Compatibility with legacy TrueAlert addressable systems upgrade and replacement see page 4 Appliance LED can be selected to display polling UL listed to Standard 1638 due to non white lens by UL testing to provide light dispersion of UL Standard 1971 at rated candela no necessary for amber or blue lens ULC listed to Standard S526 design features include Rugged high impact flame retardant thermoplastic in red with white letters or white with red available with ALERT or blank lettering Separate covers optional mounting adapters and red guards are available A separate mounting plate allows wiring to be completed appliance is mounted use with single gang double or 4 inch square box flush or surface mount wiring terminals for 18 AWG to 12 AWG clear lens TrueAlert ES appliances Refer to data sheet S49VO 0001 for strobes Refer to data sheet S49AV 0001 for A Vs These products have been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listing for 49AV APPLW BA and 7300 0026 0374 for color lens products for values and or conditions concerning material presented in this document listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products ES Notification Appliances for Emergency are available with ALERT or Blank TrueAlert ES addressable appliances are addressed and receive power supervision and signals from a Simplex fire alarm control panel IDNAC Signaling Line Circuits SLCs See list on page 4 Application Reference Proper selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA ES Operation Advantage TrueAlert ES addressable appliances on IDNAC provide separate visible and audible notification using single two wire circuit that also confirms connection to the notification appliance electronic circuit This increases circuit supervision integrity by providing that extends beyond the appliance wiring current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC source is maintained even during battery standby allowing to operate at higher voltage with lower current and a consistent current draw and voltage drop margin both primary power and secondary battery standby include wiring distances up to 2 to 3 times than with conventional notification or support for appliances per IDNAC SLC or use of smaller gauge or combinations of these benefits all providing and maintenance savings with high assurance appliances that operate during normal system testing operate during worst case alarm conditions 11 2016 TrueAlert ES Operation Advantage Cont Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction can significantly reduced When Class B wiring is used can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test improves installation efficiency TrueAlert device conveniently identify information about each appliance ES Diagnostics Test Features When IDNAC SLCs are in diagnostic Self Test and Magnet Test features provide individual testing With the Self Test feature appliance can be confirmed without leaving the control panel each appliance LED can be selected to pulse it receives a supervision poll during normal operation Details Selecting Self Test Mode from the control allows on board sensors depending on the device type detect its own strobe and or horn output and then report their to the control panel Product Selection TrueAlert ES Diagnostics Continued Self Test Details Continued Operation is by selected appliance groups and is either automatic all briefly activated or individually activated by applying magnet Refer to control panel data sheet for more Self Test see list on page 4 Appliance Magnet Test In this test mode in to application of a magnet the appliance LED sequentially to conveniently indicate the appliance Appliance Magnet Test In this test mode the address is indicated by pulsing the appliance LED strobe will briefly flash to indicate proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert ES appliances to its to test IDCs NACs and IDNet communications connection to the control panel Please contact your Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring See data sheet ES Wall Mount Addressable Strobes V O with Color Lens Color Lettering Lens Color Description Appliance Selection Lens covers include correct intensity selection plug assembly with amber lens cover housing cover with color lettering as indicated and matching mounting plate Dimensions cover 5 H x 5 W x 2 D 130 mm x 127 mm x 67 mm V O Housing for color lens Emergency Communications Appliances Lens Covers Mounting Plate Required when ordering model 49VO APPLWE BA or 49AV APPLW BA Housing has setting on board for selecting color lens applications lens cover housing cover mounting plate separately White Note BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW and APPLWE and separate mounting plates are assembled in the USA Covers Required when ordering model 49VO APPLWE BA or 49AV APPLW BA ALERT Lettering Adapters and Wire Guard ALERT Lettering Blank Lettering Blank Lettering Mount Adapter Skirt Description White Red Adapter Plate for mounting to Simplex 2975 9145 typically for retrofit mount vertical or horizontal Red Mounting