Simplex TrueAlert Addressable Operation Reference & 4009 Series TrueAlert Addressable Controller
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-operation-reference-4009-series-truealert-addressable-controller-4231896705.pdf |
---|---|
Type | |
Size | 1.21 MB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Reference Addressable Operation Reference Series TrueAlert Addressable Controller for installed system expansion applications Refer to page 7 for appliance compatibility details For new addressable notification fire alarm control panel refer to data sheet S4100 0100 Addressable Operation Features Each individually addressed notification appliance power and control over a single wire pair Supervised wiring connections to each appliance that using wiring for Class B circuits A circuits require in out wiring Horns sounding with selectable high or low output as 3 or March Time pattern 60 or 120 bpm or On controlled separately from visible appliances the same two wire circuit Visible appliances operating synchronized at 1 Hz Control over power limited isolated output Signaling Circuits SLCs with up to 63 addressable per SLC and up to 189 appliances per control refer to page 7 for detailed SLC ratings Control sources selectable to provide individual appliance test mode and appliance LED polling indicator 4100ES 4100U and 4010ES systems also provide control capabilities using Virtual NAC appliance groupings across SLCs and across sources B wiring advantages Less wiring distance is required since traditional Class B wiring supervision is not needed With less wiring distance required voltage drops can be allowing more appliances per wire run listed to Standard 864 TrueAlert Power Supplies TPS For mounting in 4100ES 4100U control panels Three 3 A SLCs Special Application rating Addressable Controllers Remote mounted control panel that provides Three 2.5 A SLCs Special Application rating An 8 A power supply battery charger for internal up to 12.7 Ah or up to 18 Ah in external cabinet communications formats are available Remote Unit Interface RUI communications Simplex 4100ES 4010ES 4100U 4120 4100 4020 alarm control panels 4100U 4120 4100 4020 rev 9 software or higher assigns an address with custom label to each appliance for individual reporting communications from Simplex 4010 fire alarm panels provide individual or multiple channel using a single IDNet address Wired control from conventional NACs connects with options Fire Alarm Panel with TPS addressable appliances Module 24V DNET IDNET NE PWR NE PWR DC DC TIME RECORDER CO ZAM CLASS B INSTR 574 183 CODE TrueAlert Channels options IDNet Channel Repeater SCO NNECT W ER RE SERVI CI NG Addressable Controller DOWN 24V DNET I DNET PW R PW R DC DC TIME RECORDER CO 9101 ZAM CLASS B INSTR 574 183 CODE Communications Wired Control IDNet IS NORMAL 12 02 15pm Fri 19 Feb 99 I R E L A RM Y S T E M U P E RV I S O RY Y S T E M R O U BL E L A R M L E N C ED W E R LA R M C K U P V C K O U B LE C K L AR M L E N C E Y ST E M E S E T Fiber Optic IDNet SYSTEM I S NO RM AL 12 02 15pm M on 9 Feb 98 I R E L A R M Y S T E M U P E R V I S O Y S T E M R O U B L E L A R M I L E N C E D Y C O W E R L A R M C K U P V C K T R O C K B L E L A R M I L E N C E Y S T E M E S E T RE ALARM NTRO L O N I S C O N N E C T O W E R B E F O R E R V I C I N G Fiber Transmitter Alarm Panel 4100U 4010ES 4120 or 4020 Fire Control Panel Fire Alarm Panel Addressable Operation Reference Diagram Addressable Controllers Contd Extensive internal diagnostics include LED status indicators that identify channel and trouble Support for host fire alarm control panel WALKTEST test with IDNet or RUI communications Status monitoring of battery input power and earth internal modules Class A Three Channel Adapter Module Communications Repeater or Fiber Optic models for Class A or Class B accessories Remote TrueAlert communications isolator 4905 9929 communication fiber optic transmitters to data sheet S4905 0001 for details External battery cabinet for 18 Ah batteries NOTE Model 4009 9501 240 VAC input is not included in these listings Refer to 2 for specific applicable listings by model 4009 9401 120 VAC input has been by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code See CSFM Listing 7310 0026 214 for allowable values conditions concerning material presented in this document 4009 9401 is accepted use City of New York Department of Buildings MEA35 93E Additional listings may applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection 9 2015 Introduction TrueAlert addressable notification appliances are addressed and receive power supervision control from a TrueAlert Signaling Line Circuit For wired control systems strobe flashes and horn are synchronized per controller For RUI and communications control controllers on the same control panel are synchronized Combination TrueAlert appliances receive audible from separate audio circuit wiring addressable operation allows strobes to wired onto the same two wire SLC circuit as horns but separately controlled operation Typical applications audible notification appliances activated as and visible notification appliances as Addressable Controller diagnostics can implemented from the control panel including Silent Active individual appliance magnet test appliance polling indication or all appliance LEDs on Communications Control used with fire alarm control panels that support RUI the TrueAlert Addressable Controller can connected to an RUI addressable communications along with other RUI addressable devices The host can control multiple TrueAlert Addressable maximum recommended is 20 per RUI note 4010ES system is limited to 20 internal external card addresses per panel Refer to the diagram page 3 for additional information TrueAlert Addressable Controller Product Selection Models RUI Communications Control Continued Address points and custom labels are assigned to each appliance allowing troubles to be reported Additionally individual device types are and audible appliance coding types are selectable high or low output 5 dBA difference and with as Temporal pattern March Time pattern 60 or bpm or Steady On continuous and 4010ES VNAC Details Virtual NAC VNACs Operation Groupings control of TrueAlert appliances similar to NAC operation but VNACs include across SLCs and across SLC sources within a or 4100U or 4010ES controlled system require point allocation can be declared use in a Network fire alarm system and can be controlled NOTE The terms Virtual NAC and TrueAlert Zone refer to the same feature and interchangeable VNACs For programming convenience there default VNAC groups according to device type Up to custom VNACs 8 VNACs are system reserved can created per 4100ES TPS or per TrueAlert Addressable connected to a 4100ES or 4010ES control Appliances are able to be in up to three custom NOTE Appliances assigned to multiple will remain ON if any of the VNACs are ON 4100U and 4010ES Fire Alarm Control Panels be programmed for up to 247 total custom VNACs incre