Simplex TrueAlert Addressable S V, Ceiling Mount
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-addressable-s-v-ceiling-mount-1375486290.pdf |
---|---|
Type | |
Size | 690.05 KB |
Downloads |
Text Preview
TrueAlert Addressable Notification Appliances ULC Listed FM CSFM MEA NYC Approved Speaker Visible Notification Appliances with Addressable Strobe Ceiling Mount ceiling mount notification with Multi tapped speaker TrueAlert individually addressable high intensity strobe notification appliance speaker High quality voice and tone reproduction with taps for 1 2 1 or 2 W at 25 or 70.7 VRMS UL listed to Standard 1480 Speaker is wired separately from TrueAlert strobe wiring addressable visible notification strobe Xenon strobe available with 15 75 or 110 candela strobe rating is clearly indicated on reflector UL listed to Standard 1971 Each individual strobe wiring and connections are supervised to the strobe assembly Strobe flashes at a synchronized 1 Hz rate Compatible with ADA requirements Magnetic test diagnostics to assist checkout and of TrueAlert addressable strobe and wiring Rugged high impact flame retardant thermoplastic addressable strobe LED indicator and test feature LED indicator can be selected to display each polling to indicate appliance supervision When the TrueAlert addressable control is in mode the magnetic test pulses the LED to appliance address and is selectable to also flash the strobe to confirm operation addressable notification appliance provides Round housing for ceiling mount in standard boxes Separate in out wiring terminals for speaker and 18 AWG to 12 AWG This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Mount TrueAlert Addressable S V Appliances White Housings with Red Lettering addressable speaker visible S V appliances combine a multi tapped and an individually addressed strobe to provide notification and visible notification from the appliance Speakers and strobes are wired addressable operation allows strobes to power supervision and control signals from a addressable Signaling Line Circuit SLC When activated the strobes flash at a rate Addressable Advantage Speaker Visible S V applications the of TrueAlert addressable two wire operation available for the wiring required for strobe operation advantages are available for applications using and strobe appliances Selection selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA TrueAlert addressable notification is protected under U S Patent Nos 6,313,744 and 6,693,532 7 2005 Addressable Advantage Cont Addressable Diagnostics addressable operation uses a single circuit that provides strobe power and that confirms the integrity of the to the individual strobe electronic circuit operation increases circuit supervision integrity by supervision that extends beyond the appliance connections for Reducing Installation and Time When Class B Style 4 strobe wiring is wiring can be tapped allowing potential in distance wire junction boxes and overall efficiency The magnetic test feature see next also can provide improved installation efficiency Addressable Control addressable notification appliances are by a TrueAlert Addressable Power Supply in a Series control panel or by a 4009 9401 TrueAlert Controller an intelligent interface panel between the host fire alarm control panel and TrueAlert addressable notification appliances Refer data sheet S4009 0003 for further information about TrueAlert Addressable Controller and S4100 0031 for information Product Selection Number Bridge Sound Attenuation per ULC S541 Indicator The host TrueAlert addressable can be selected to pulse each appliance LED that appliance receives a supervision poll Test When the host TrueAlert addressable is selected for diagnostic mode the TrueAlert appliance magnetic test feature provides a at the individual appliance being tested Appliance Testing In this test mode in to the magnetic test the appliance LED pulses to conveniently indicate the appliance Appliance Testing The LED diagnostic mode can be selected at the TrueAlert addressable such that after the address is indicated the strobe briefly flash to indicate proper operation Addressable Wiring Isolator 4905 9929 Isolator Module is available for use TrueAlert addressable circuits to isolate short circuited from functioning wiring Refer to data sheet for further information about the TrueAlert Isolator Module Color with red lettering diagram on page 4 Ceiling Mount Notification Appliances with TrueAlert Addressable Strobes Output Rating cd cd cd to of strobe to of strobe 80 70 60 50 40 30 20 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 20 30 40 50 60 70 80 90 Displacement Degrees on Horizontal Axis Displacement Degrees on Horizontal Axis 7 2005 S V Specifications Specifications Voltage Range Requirements Flash Rate Application 17 to 31 VRMS see Notes 1 and 2 below unit load Hz SLC Loading to 43 TrueAlert addressable synchronized strobes maximum per SLC RMS Current Rating per Strobe see Notes 2 and 3 below RMS Currents at other VRMS VRMS cd mA mA mA cd mA mA mA cd mA mA mA Specifications Voltage Taps Response or 70.7 VRMS see Note 4 below 1 2 1 and 2 W Alarm 400 to 4000 Hz Signaling 125 to 12 kHz Output Ratings 10 ft 3 m with either 25 VRMS or 70.7 VRMS input 1480 Reverberant Chamber Test dBA Tap W W dBA W dBA W dBA Specifications into Box Tap Selection Range Range Housing 7 1 2 Diameter 1 2 D 191 mm x 13 mm Lens Protrusion 2 5 8 above speaker housing 67 mm jumper wire with pressure connector attaches to one of 8 terminals 70 mm to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 separate terminals for and TrueAlert addressable strobe connection TrueAlert addressable strobes are required to be connected to a TrueAlert addressable channel where both power and are supplied Refer to TrueAlert Addressable Controller data sheet S4009 0003 for additional information wiring rules and distance limitations Application refers to the operating category under UL Standard 1971 Signaling Devices for the