Simplex TrueAlert ES Addressable Notification Appliances; Audible Notification Appliances, Electronic Horns, Model Series 49AO ; 49AO-0001
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-es-addressable-notification-appliances-audible-notification-appliances-electronic-horns-model-series-49ao-49ao-0001-3417028965.pdf |
---|---|
Type | |
Size | 1.36 MB |
Downloads |
Text Preview
TrueAlert Addressable Notification Appliances Notification Appliances Electronic Horns Model Series 49AO ULC CSFM Listed FM addressed and controlled low power TrueAlert ES A audible only electronic horns Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes on the same SLC to operate with current even under battery backup Wiring supervision to each appliance allows T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode allows an on board sensor to detect the horn output then report its status to the control panel Horns are controlled separately from visible appliances on the same with control panel selection of operation as Temporal Code March Time selectable as 20 60 or 120 bpm Continuous or Code 4 Output of high or low 6 dBA difference selectable at the or from the controller with FACP mode selected at the Unobtrusive Magnet Test diagnostics are available to assist checkout testing of appliances and wiring Electrical test point access without removing cover Compatible with legacy TrueAlert addressable systems for upgrade and See TrueAlert ES Horn LEGACY Compatibility Reference more information Listed to UL Standard 464 and ULC Standard S525 Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses LED to indicate appliance address and is selectable to also briefly the horn to confirm operation design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters available with FIRE FEU or blank Separate covers are available to change application type on site or replacement covers can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 inch box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted boxes and to adapt to Simplex 2975 9145 boxes Optional red wire guards See Product Selection for more information ES addressable horns ES addressable horns are individually addressed audible appliances that receive power supervision and control from a Simplex fire alarm control panel providing IDNAC Line Circuits SLCs See TrueAlert ES Horn LEGACY Reference for more information 1 TrueAlert ES Addressable Horns are Available in with White Lettering and White with Red Lettering ES Operation Advantage ES addressable appliances on IDNAC SLCs provide separate and visible notification using a single two wire circuit that also connection to the individual notification appliance electronic This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections current allows efficient IDNAC SLC operation IDNAC SLCs a constant 29 VDC source voltage is maintained during battery standby allowing strobes on the same SLC to at higher voltage with lower current and ensuring a consistent draw and voltage drop margin under both primary power secondary battery standby Efficiencies include wiring distances to 2 to 3 times farther than with conventional notification or for more appliances per IDNAC SLC or use of smaller gauge or combinations of these benefits all providing installation and savings with high assurance that appliances that operate normal system testing will operate during worst case alarm Installation and Testing Time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be T tapped allowing savings in distance wire conduit size and utilization and installation efficiency Use of Self Test and Magnet Test features installation efficiency TrueAlert device reports conveniently information about each connected appliance products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7135 0026 0372 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Rev 7 3 2018 Notification Appliances Electronic Horns Model Series 49AO ES Diagnostics Features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test feature appliance can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it receives a supervision during normal operation Details Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and or horn output then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see TrueAlert ES Horn Compatibility Reference for more information Appliance Magnet Test this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address Appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the horn will briefly sound to indicate proper operation Instrument Two TSIT 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control panel Please contact your local Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring data sheet S4905 0001 1 TrueAlert ES Addressable Electronic Horns Color with Cover Selection logo only cover and mounting plate separately ES addressable AO audible horn appliance includes cover matching mounting plate H x 5 W x 1 D 130 mm x mm x 38 mm 2 Separate Mounting Plate Required when ordering model 49AO APPLW plate select color to match cover 3 Separate Covers Required when ordering model 49AO APPLW BA logo only 2 Rev 7 3 2018 Notification Appliances Electronic Horns Model Series 49AO 4 Mounting Adapters and Wire Guard Mount Adapter Skirt Adapter Plate for mounting to Simplex 2975 9145 Box typically for mount vertical or horizontal Mounting Box requires 4905 9931 Adapter Plate wire guard with mounting plate compatible with semiflush or surface boxes H x 5 W x 1 D 136 mm x mm x 41 mm Total depth with 3 79 mm 5 16 x 5 x 0.060 Thick 211 mm 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 x 70 mm 1 16 H x 6 1 16 W x 3 D 154 x 154 mm x 79 mm ES Horn Specifications 5 Electrical Ratings Operating Voltage Range Current Rating Requirements SLC Loading VDC to 31 VDC Special Application see below for 17 VDC ratings mA maximum 31 VDC use this for all applications unit load 0.8 mA control panel current of 127 addresses per SLC 139 unit loads 6 Sound Output Ratings 10 ft 3 m 23 VDC with IDNAC SLCs Type Setting Chamber UL 464 Test Chamber ULC 525 Test dBA