Simplex TrueAlert ES Addressable Notification Appliances; Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-es-addressable-notification-appliances-audible-notification-appliances-multi-tone-horns-with-520-hz-output-1503842967.pdf |
---|---|
Type | |
Size | 994.29 KB |
Downloads |
Text Preview
ULC CSFM Listed Approved Addressable Notification Appliances Notification Appliances Horns with 520 Hz Output Individually addressed and controlled TrueAlert ES electronic horns Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each appliance allows for Class B circuits to simplify wiring A circuits require in out wiring Self Test Mode allows an on board sensor to detect the output and then report its status to the control panel Per appliance tone selection of 520 Hz Horn Broadband Bell Chime High Low Slow Whoop or Siren from the control panel or selected using on board DIP Switch see sound output details on p 4 520 Hz tone is compliant with NFPA 72 Low Frequency Requirements for Sleeping Areas Listed for wall or ceiling mount applications blank are recommended for ceiling mount applications Horn Bell and High Low tones can be controlled as Code 3 Temporal Code 4 March Time as 20 60 or 120 bpm or Continuous Slow Whoop Siren and Chime tone selections are as synchronized continuous operation Output of or 6 dBA difference at the appliance or from the controller with mode selected at the appliance Unobtrusive Magnet Test diagnostics are available to checkout and testing of appliances and wiring Electrical test point access without removing cover Listed to UL Standard 464 and ULC Standard S525 Indicator and Magnet Test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the Magnet pulses the LED to indicate appliance address and is to also briefly sound the horn to confirm design features include Rugged high impact flame retardant thermoplastic in red with white letters or white with red letters with FIRE FEU FEU FIRE or blank lettering Separate covers are available to change application type or for replacement covers can be easily removed disturbing the connected housing and avoiding conditions A separate mounting plate allows wiring to be completed appliance is mounted use with single gang double or 4 inch square box flush or surface mount wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to Simplex boxes ES Multi Tone Addressable Horns are Available Red with White Lettering and White with Red Lettering ES multi tone horns are individually audible notification appliances that receive supervision and control signals from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 ES Operation Advantage ES addressable appliances on IDNAC provide separate audible and visible notification a single two wire circuit that also confirms connection the individual notification appliance electronic circuit operation increases circuit supervision integrity by supervision that extends beyond the appliance connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC source is maintained even during battery standby allowing on the same SLC to operate at higher voltage with current and ensuring a consistent current draw and drop margin under both primary power and battery standby Efficiencies include wiring up to 2 to 3 times farther than with conventional or support for more appliances per IDNAC or use of smaller gauge wiring or combinations of benefits all providing installation and maintenance with high assurance that appliances that operate normal system testing will operate during worst case conditions This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7135 0026 0379 allowable values and or conditions concerning material presented in this document listings may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 7 2016 TrueAlert ES Operation Advantage Cont Reducing Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test improves installation efficiency TrueAlert device conveniently identify information about each appliance ES Diagnostics Test Features When IDNAC SLCs are in diagnostic Self Test and Magnet Test features provide individual testing With the Self Test feature appliance can be confirmed without leaving the control panel each appliance LED can be selected to pulse it receives a supervision poll during normal operation Details Selecting Self Test Mode from the panel allows on board sensors depending on the type to detect its own strobe and or horn output and report their status to the control panel Operation is by VNAC appliance groups and is either automatic all simultaneously activated or individually activated by a magnet Refer to control panel data sheet for more information see list on page 4 Product Selection ES Addressable Multi Tone Horns TrueAlert ES Diagnostics Continued Appliance Magnet Test In this test mode in to application of a magnet the appliance LED sequentially to conveniently indicate the address Appliance Magnet Test In this test after the address is indicated by pulsing the LED the horn will briefly sound to indicate operation Instrument Two TSIT The 2nd of the Simplex TrueStart Test Instrument adds of IDNAC SLC wiring and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate circuited wiring from functioning wiring See data S4905 0001 Color with Cover ES addressable horns includes cover matching mounting plate H x 5 W x 1 D mm x 127 mm x 38 mm Select cover and mounting plate separately Mounting Plate Required when ordering model 49MT APPLW BA plate select color to match cover Note BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW models and mounting plates are assembled in the USA Covers Required when ordering model 49MT APPLW BA uses same covers as 49AO Series fixed tone horns Adapters Only Description White Red Adapter Plate for mounting to Simplex 2975 9145 Box Red Mounting Box requires 4905 9931 Adapter Plate for retrofit mount vertical or horizontal Mount Adapter Skirt H x 5 W x 1 D 136 mm x 133 mm x 41 mm depth with horn 3 79 mm 5 x 5 x 0.060 Thick 211 mm x 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 mm x 70 mm 7