Simplex TrueAlert ES Addressable Notification Appliances Audible Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn Strobe, Model Series 49AV
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
Datasheet ES Addressable Notification Appliances Notification Appliances Indoor Ceiling Mount Multi Candela Horn Strobe Series 49AV Optional red wire guards see Product Selection notification appliance horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern continuous or Code 4 controlled separately from visible appliances on the two wire circuit Selectable March Time rates of 20 60 or 120 beats per minute Output is or 5 dBA difference selectable at the appliance from the controller with FACU mode selected at the appliance ULC Listed FM Approved mount addressable visible A V notification appliances individually addressed audible visible notification appliances that power supervision and control signals from a Simplex fire alarm unit FACU providing IDNAC Signaling Line Circuits SLCs LED Xenon tube strobes devices are interoperable on the same IDNAC See TrueAlert ES A V LEGACY Compatibility Reference addressed and controlled multi candela TrueAlert ES audible visible notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the FACU or jumper selected as 15 cd 30 75 cd or 110 cd on the AV model or 110 cd 135 cd or 185 cd on AVH model Advanced addressable notification controlled by IDNAC SLCs IDNAC SLCs provide regulated 29 VDC allowing horns to operate with current Wiring supervision to each appliance allowing connections Class B circuits to simplify wiring Class A circuits require in out Self Test Mode allows on board sensors to detect the strobe and horn and then report their status to the FACU TrueAlert Device Reports at the FACU detailing appliance point ID label type and candela setting see sample in TrueAlert Device Reference Magnet Test diagnostics to assist checkout and testing of appliances wiring Electrical test point access by removing the cover Compatibility with ADA requirements see Installation Reference for installation information Compatibility with legacy TrueAlert addressable systems for upgrade replacement see TrueAlert ES A V LEGACY Compatibility Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can be set to also briefly flash strobe and sound the horn design features Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens available with FEU ALERT FEU FIRE FUEGO FOGO or blank lettering Separate covers are available to change application type onsite or for You can use a back box to mount the appliance assembly to the wall to a 4 in 10.16 cm square electrical box Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG 1 TrueAlert ES addressable A V application reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the application guidelines of Americans with Disabilities Act ADA ES operation advantage ES addressable appliances on IDNAC SLCs separate visible and audible notification using a single two circuit that also confirms connection to the individual notification electronic circuit This operation increases circuit supervision by providing supervision that extends beyond the appliance connections current usage on IDNAC SLCs IDNAC SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions installation and testing time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly You can T tap Class B wiring allowing more savings in distance conduit size and utilization and overall installation efficiency Use Self Test and Magnet Test features improve installation efficiency device reports conveniently identify information about each appliance Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co S49AVC 0001 Rev 14 08 2021 Notification Appliances Indoor Ceiling Mount Multi Candela Horn Strobe Model Series 49AV ES Diagnostics features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self test feature appliance can be confirmed without leaving the FACU Additionally each appliance LED can be selected to pulse when it receives a supervision poll normal operation details Self test mode from the FACU allows on board sensors depending on the device type to detect its own strobe and or horn output and report their status to the FACU Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously activated or activated by applying a magnet Refer to FACU data sheet for more Self Test information see list in Table 10 appliance magnet test this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address appliance magnet test this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and the horn will briefly sound to indicate operation instrument two TSIT 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control panel Contact your local Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 Model 4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring to data sheet TrueAlert Addressable Isolator Module Model 4905 9929S4905 0001 Reference 2 TrueAlert ES Addressable A V installation 2 S49AVC 0001 Rev 14 08 2021 Notification Appliances Indoor Ceiling Mount Multi Candela Horn Strobe Model Series 49AV Device Reports Reference Selection Mount Addressable Audible Visible A V Appliances ES Addressable A V appliance dimensions with cover 8 1 8 in H x 7 1 8 in W x 3 in D 206 mm x 180 mm x 76 mm 1 Ceiling Mount Addressable Audible Visual Only A V Appliances appliance only Select cover Instructions Pending Pending color Use WP back boxes for surface mounting only Using weatherproof back boxes does not make an appliance weatherproof 3 Separate Covers required when ordering model 49AV APPLC BA 2 Back boxes