Simplex TrueAlert ES Addressable Notification Appliances; Audible Visible Notification Appliances; Multi-Tone Horn Strobe with 520 Hz Output

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Approved Addressable Notification Appliances Notification Appliances Horn Strobe with 520 Hz Output Individually addressed and controlled multi tone multi candela TrueAlert ES A V audible visible appliances provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected as 15 30 75 110 135 or cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each appliance allowing connections for Class B circuits to wiring Class A circuits require in out Self Test Mode allows on board sensors to detect the and horn output and then report their status to control panel Per appliance tone selection of 520 Hz Horn Horn Bell Chime High Low Slow or Siren programmable from the control or selected using an on board DIP Switch refer sound output details on page 4 520 Hz tone is compliant with NFPA 72 Low Signal Requirements for Sleeping Areas Horn Bell and High Low tones can be controlled as Code 3 Temporal Code 4 March Time as 20 60 or 120 bpm or Continuous Slow Whoop Siren and Chime tone selections are as synchronized continuous operation Output of or 6 dBA difference at the appliance or from the controller with mode selected at the appliance TrueAlert Device Reports at the control panel appliance point ID custom label type and setting see sample on page 3 Magnet Test diagnostics to assist checkout and testing appliances and wiring Electrical test point access without removing cover Compatibility with ADA requirements refer to installation information on page 3 Strobe operation is listed to UL Standard 1971 and Standard S526 Horn operation is listed to UL 464 and ULC Standard S525 Indicator and Magnet Test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the Magnet pulses the LED to indicate appliance address and be set to also briefly flash the strobe and sound the ES Multi Tone Addressable A Vs are Available Red with White Lettering and White with Red Lettering Continued Mechanical design features include Rugged high impact flame retardant thermoplastic in red with white letters or white with red letters clear lens available with FIRE FEU ALERT or blank lettering Separate covers are available to change application type or for replacement covers can be easily removed disturbing the connected housing and avoiding conditions A separate mounting plate allows wiring to be completed appliance is mounted use with single gang double or 4 inch square box flush or surface mount wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to Simplex boxes TrueAlert ES addressable multi tone A Vs are addressed audible visible notification that receive power supervision and control from a Simplex fire alarm control panel providing Signaling Line Circuits SLCs See list on page 4 Application Reference Proper selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co the property of Tyco Fire Protection Products 7 2016 TrueAlert ES Operation Advantage TrueAlert ES addressable appliances on IDNAC provide separate visible and audible notification a single two wire circuit that also confirms to the individual notification appliance circuit This operation increases circuit integrity by providing supervision that beyond the appliance wiring connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm Reducing Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test improve installation efficiency TrueAlert device conveniently identify information about each appliance Product Selection TrueAlert ES Diagnostics Test Features When IDNAC SLCs are in diagnostic Self Test and Magnet Test features provide individual testing With the Self Test feature appliance can be confirmed without leaving the control panel each appliance LED can be selected to pulse it receives a supervision poll during normal operation Details Selecting Self Test Mode from the control allows on board sensors depending on the device type to its own strobe and or horn output and then report their to the control panel Operation is by selected VNAC groups and is either automatic all briefly activated or individually activated by applying magnet Refer to control panel data sheet for more Self Test see list on page 4 Appliance Magnet Test In this test mode in to application of a magnet the appliance LED pulses to conveniently indicate the appliance address Appliance Magnet Test In this test mode the address is indicated by pulsing the appliance LED the will briefly flash and the horn will briefly sound to proper operation Instrument Two TSIT The 2nd generation of Simplex TrueStart Test Instrument adds testing of IDNAC wiring and TrueAlert ES appliances to its ability to test NACs and IDNet communications before connection to control panel Please contact your local Simplex for additional information Addressable Wiring Isolator Isolator Model 4905 9929 is available for remote mounting TrueAlert addressable circuits to isolate short circuited from functioning wiring See data sheet S4905 0001 ES Wall Mount Multi Tone Addressable Audible Visible Appliances ES multi tone addressable A V appliances include cover and matching mounting plate except as noted with Cover 5 H x 5 W x 2 D 130 mm x 127 mm x 67 mm Color Color Color Color Mounting Plate Required when ordering model 49MTV APPLW BA cover and mounting plate separately Note BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW models and separate plates are assembled in the USA Covers Required when ordering model 49MTV APPLW BA uses same covers as 49AV Series fixed tone A Vs Plate select color to match cover Only

Related Files