Simplex TrueAlert ES Addressable Notification Appliances; Audible Visible Notification Appliances, Wall Mount Multi-Candela Horn Strobe, Chinese English

File Preview
File Preview
Click below to download for free

Text Preview

UL Listed Addressable Notification Appliances Notification Appliances Wall Mount Horn Strobe Chinese English addressed and controlled multi candela ES A V audible visible notification provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected as 15 30 75 110 135 or 185 cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the and horn output and then report their status to the panel TrueAlert Device Reports at the control panel detailing point ID custom label type and candela see sample on page 3 Magnet Test diagnostics to assist checkout and testing appliances and wiring Electrical test point access without removing cover Compatibility with ADA requirements refer to installation information on page 3 Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 4 Strobe operation is listed to UL Standard 1971 operation is listed to UL Standard 464 Indicator and Magnet Test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the Magnet pulses the LED to indicate appliance address and be set to also briefly flash the strobe and sound the design features include Rugged high impact flame retardant thermoplastic in white with red letters with clear lens and lettering Cover can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be before appliance is mounted use with single double gang or 4 inch square box flush or mount Covers can be easily removed without disturbing the housing and avoiding trouble conditions wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to 2975 9145 boxes Optional red wire guards see page 2 for details ES Addressable A V with Red Lettering Continued notification appliance horn Harmonically rich output sound for either coded or operation Horns sound as Temporal Code 3 March Time continuous or Temporal Code 4 controlled from visible appliances on the same circuit Selectable March Time rates of 20 60 or 120 beats minute Output is or 5 dBA difference at the appliance or from the controller with mode selected at the appliance ES addressable A Vs are individually visible notification appliances that receive supervision and control signals from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Additional listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products 6 2015 ES Operation Advantage TrueAlert ES addressable appliances on IDNAC provide separate visible and audible notification a single two wire circuit that also confirms to the individual notification appliance circuit This operation increases circuit integrity by providing supervision that beyond the appliance wiring connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test improve installation efficiency TrueAlert device conveniently identify information about each appliance ES Diagnostics Test Features When IDNAC SLCs are in diagnostic Self Test and Magnet Test features provide individual testing With the Self Test feature appliance can be confirmed without leaving the control panel each appliance LED can be selected to pulse it receives a supervision poll during normal operation Details Selecting Self Test Mode from the control allows on board sensors depending on the device type detect its own strobe and or horn output and then report their to the control panel Operation is by selected VNAC groups and is either automatic all briefly activated or individually activated by applying magnet Refer to control panel data sheet for more Self Test see list on page 4 Appliance Magnet Test In this test mode in to application of a magnet the appliance LED pulses to conveniently indicate the appliance address Appliance Magnet Test In this test mode the address is indicated by pulsing the appliance LED the will briefly flash and the horn will briefly sound to proper operation Instrument Two TSIT The 2nd generation of Simplex TrueStart Test Instrument adds testing of IDNAC wiring and TrueAlert ES appliances to its ability to test NACs and IDNet communications before connection to control panel Please contact your local Simplex for additional information Addressable Wiring Isolator Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring See data sheet Product Selection ES Wall Mount Addressable Audible Visible Appiance ES addressable A V appliance housing select cover and mounting plate separately with Cover 5 H x 5 W x 2 D 130 mm x 127 mm x 67 mm Mounting Plate Required White mounting Plate Cover Required ALARM Adapters and Wire Guard Mount Adapter Skirt wire guard with mounting plate with semi flush or surface boxes H x 5 W x 1 D 136 mm x 133 mm x 41 mm depth with strobe 4 111 mm 1 H x 6 1 W x 3 D 154 mm x 154 mm x 79 mm 6 2015 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 1 TUE 27 Jan 15 Installation Reference is compatible with single gang gang and 4 102 mm square boxes 38 mm deep sup

Related Files