Simplex TrueAlert ES Addressable Notification Appliances; Multi-Candela Visible Only (V O) Appliances (Strobes), Ceiling Mount, Chinese English

File Preview
File Preview
Click below to download for free

Text Preview

UL Listed Addressable Notification Appliances Notification Appliances Wall Mount Strobe Chinese English addressed and controlled multi candela ES V O visible only notification provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected as 15 30 75 110 135 or 185 cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring Self Test Mode allows an on board sensor to detect the output and then report its status to the control TrueAlert Device Reports at the control panel detailing point ID custom label type and candela see sample on page 3 Magnet Test diagnostics to assist checkout and testing of and wiring and Electrical test point access removing cover Compatibility with ADA requirements refer to installation information on page 3 Compatibility with legacy TrueAlert addressable systems upgrade and replacement see page 4 Listed to UL Standard 1971 Indicator and Magnet Test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the Magnet pulses the LED to indicate appliance address and be set to also briefly flash the strobe design features include Rugged high impact flame retardant thermoplastic in white with red letters with clear lens and lettering Cover can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed appliance is mounted use with single gang double or 4 inch square box flush or surface mount wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to 2975 9145 boxes Optional red wire guards see page 2 for details Additional listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products ES Addressable Strobe with Red Lettering ES addressable strobes are individually visible notification appliances that receive supervision and control signals from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA ES Operation Advantage ES addressable appliances on IDNAC provide separate visible and audible notification a single two wire circuit that also confirms connection the individual notification appliance electronic circuit operation increases circuit supervision integrity by supervision that extends beyond the appliance connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC source is maintained even during battery standby allowing to operate at higher voltage with lower current and a consistent current draw and voltage drop margin both primary power and secondary battery standby include wiring distances up to 2 to 3 times than with conventional notification or support for appliances per IDNAC SLC or use of smaller gauge or combinations of these benefits all providing and maintenance savings with high assurance appliances that operate during normal system testing operate during worst case alarm conditions 6 2015 ES Operation Advantage Cont Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test improves installation efficiency TrueAlert device conveniently identify information about each appliance ES Diagnostics Features When IDNAC SLCs are in diagnostic Self Test and Magnet Test features provide individual testing With the Self Test feature appliance can be confirmed without leaving the control Additionally each appliance LED can be selected to when it receives a supervision poll during normal Details Selecting Self Test Mode from the panel allows on board sensors depending on the type to detect its own strobe and or horn output and report their status to the control panel Product Selection ES Diagnostics Continued Details Continued Operation is by selected appliance groups and is either automatic all briefly activated or individually activated by a magnet Refer to control panel data sheet for Self Test information see list on page 4 Appliance Magnet Test In this test mode in to application of a magnet the appliance LED sequentially to conveniently indicate the address Appliance Magnet Test In this test after the address is indicated by pulsing the LED the strobe will briefly flash to indicate operation Instrument Two TSIT The 2nd of the Simplex TrueStart Test Instrument adds of IDNAC SLC wiring and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring See data sheet ES Wall Mount Addressable Strobe ES addressable VO strobe appliance housing select cover and mounting plate separately with Cover 5 H x 5 W x 2 D 130 mm x 127 mm x 67 mm Mounting Plate Required White mounting Plate Cover Required ALARM Adapters and Wire Guard Mount Adapter Skirt wire guard with mounting plate with semi flush or surface boxes H x 5 W x 1 D 136 mm x 133 mm x 41 mm depth with strobe 4 111 mm 1 H x 6 1 W x 3 D 154 mm x 154 mm x 79 mm 6 2015 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 1 TUE 27 Jan 15 Installation Reference is compatible with single gang gang and 4 102 mm square boxes 38 mm deep supplied separately terminals and clips assembly cover bladed screwdriver to latch on left side setting DIP accessible rear of housing test location of housing test point access holes bottom WALL MOUNT HEIGHT REFERENCE outline of lens is even with or above bottom compatible boxes 72 requires the entire lens be less than 80 and greater than 96 the finished confirm with local codes indicator intensity slot on of applian

Related Files