Simplex TrueAlert ES Addressable Notification Appliances Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49VO

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved ES Addressable Notification Appliances Only Notification Appliances Indoor Ceiling Mount Strobe Model Series 49VO mount addressable visible V O notification appliances individually powered addressed and controlled from a Simplex alarm control unit FACU IDNAC Signaling Line Circuit SLC V O appliances use a multi candela strobe with synchronized 1 flash rate and selectable candela rating Xenon tube strobes devices interoperable on the same IDNAC channel Separate appliance and selection greatly simplifies the ordering and installation process addressed visible only V O notification appliances Multi candela Xenon strobe available in low 15 cd 30 cd 75 cd and cd and high 110 cd 135 cd and 185 cd range candela models Small compact design and low current draw due to energy efficient tube strobes with LED indicators Advanced addressable notification controlled by IDNAC SLCs IDNAC SLCs provide regulated 29 VDC allowing horns to operate with current Electrical test point access by removing the cover Strobe intensity can be programmed from the FACU or the device Wiring supervision to each appliance allows T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the strobe output then report their status to the FACU TrueAlert Device Reports at the FACU detail appliance point ID custom type and candela setting Magnet test diagnostics assist checkout and testing of appliances and 1 Indoor ceiling mount strobe application reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the application guidelines of Americans with Disabilities Act ADA Compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard S526 Synchronized strobe operation on its IDNAC channel indicator and magnet test feature Indicator LED indicates magnet test acknowledgment 3 digit IDNAC addressable wiring isolator model 4905 9929 model 4905 9929 is available for remote mounting on TrueAlert circuits to isolate short circuited wiring from functioning Refer to data sheet TrueAlert Addressable Isolator Module Model S4905 0001 for additional information and candela rating supervision Indicator LED can be configured to blink every polling cycle to indicate When the controller is in diagnostic mode the magnet test pulses the LED to indicate appliance address and can be set to also flash the strobe LEDs design features Rugged high impact flame retardant thermoplastic housing in red and colors white with red letters Various covers and lettering options available Red with white letters Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Mounts on 4 in square or single gang USA electrical boxes Adapter required for mounting on single gang electrical boxes Optional wire guards Weatherproof back boxes are required for surface mounting ES diagnostics features can be selected to pulse each appliance LED when it a supervision poll When the controller is selected for diagnostic the appliance magnet test feature provides a response at the appliance being tested appliance magnet test appliance LED pulses sequentially to conveniently indicate the address when a magnet is applied appliance magnet test this test mode after the address is indicated by pulsing the appliance the strobe will briefly flash to indicate proper operation instrument two TSIT 2nd generation of the Simplex TrueStart Test Instrument adds of IDNAC SLC wiring and TrueAlert ES appliances to its ability test IDCs NACs and IDNet communications before connection to FACU Contact your local Simplex representative for additional Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co S49VOC 0001 Rev 14 08 2021 Only Notification Appliances Indoor Ceiling Mount Strobe Model Series 49VO reference 2 Indoor Ceiling Mount Strobe installation SLC operation advantage Addressable visible appliances on IDNAC SLCs Addressable visible appliances on IDNAC SLCs provide visible notification using one two wire circuit that also confirms connection to the notification appliance electronic circuit This operation increases circuit supervision integrity by providing supervision that extends beyond appliance wiring connections current usage on IDNAC SLCs constant 29 VDC source voltage is maintained even during battery standby This allows appliances to operate at higher voltage with lower current ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby Efficiencies include wiring up to 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC use of smaller gauge wiring or of these benefits Installation and Testing Time separate controls on the same two wire SLC installation time and expense for both retrofit and new construction can be significantly reduced Class B wiring is used wiring can be T tapped allowing more savings in distance wire conduit size and utilization and overall installation Use of the magnet test feature improves installation efficiency TrueAlert device reports conveniently identify information about each appliance selection 1 Ceiling mount addressable visual only V O appliances color Instructions appliance only Select cover Use WP back boxes for surface mounting only Using weatherproof back boxes does not make an appliance weatherproof 2 Surface WP back boxes back box in red back box in white instructions 2 S49VOC 0001 Rev 14 08 2021 Only Notification Appliances Indoor Ceiling Mount Strobe Model Series 49VO 3 Adapter plates Ceiling Mount Adapter Plate Required for mounting on single gang electrical box Instructions 4 V O covers required when ordering APPLC models logo only logo only 5 Wire guards Ceiling Mount Red Wire Guard Ceiling Mount Wire Guard Back Box BA indicates model is available either with or without the BA suffix Model numbers ending in are assembled in the USA SLC controller compatibility reference 6 Compatibility reference Controllers with EPS or EPS Power Supply IDNAC Repeater Flex 35 50 and 100 Amplifiers Constant Supervision and Signal Cards See TrueAlert ES V O LEGACY compatibility reference for 17 VDC ratings Sheet SLC mount V O specifications 7 Specifications SLC Output Voltage VDC Voltage Reference VDC 6 VDC drop SLC Loading to 120 0 to 49 10 to 93 n

Related Files