Simplex TrueAlert ES Addressable Notification Appliances; Wall Mount Weatherproof Notification Appliances; Visible Only (V O) and Audible Visible (A V); UL Listed; 49WP-0001
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
UL CSFM Listed FM Approved Addressable Notification Appliances Mount Weatherproof Visible and Audible Visible Notification Appliances blank Mounting matches weatherproof boxes required ordered separately Separate covers are available to change application type on site or for In out wiring terminals for 18 AWG to 12 AWG Enclosure is rated NEMA 3R Convenient wiring terminal access at front of housing listings UL 1638 listed for outdoor applications with strobe rated at 75 cd or 185 cd WP185 UL 1971 listed for indoor applications with strobe intensity selectable 15 or 75 cd indoor applications are compatible with ADA Horn operation is listed to UL Standard 464 Refer to data sheet S49WP 0002 for ULC listed models A V Models with horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern continuous or Code 4 controlled separately from visible appliances on the two wire circuit Selectable March Time rates of 20 60 or 120 beats per minute Output is high or low 5 dBA difference selectable at the appliance from the controller with FACU mode selected at the appliance Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA ES Operation visible and audible notification ES addressable appliances on IDNAC SLCs provide separate and audible notification using a single two wire circuit that also connection to the individual notification appliance electronic This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections current allows efficient IDNAC SLC operation IDNAC SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions Installation and Testing Time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be T tapped allowing savings in distance wire conduit size and utilization and installation efficiency Use of Self Test and Magnet Test features installation efficiency TrueAlert device reports conveniently information about each connected appliance 1 A V top and Strobe bottom view of A V on Weatherproof Mounting Boxes right ES weatherproof addressable appliances provide visible audible visible notification for indoor and outdoor extended and extended humidity applications They are individually and receive power supervision and control signals from a fire alarm control unit providing IDNAC Signaling Line Circuits addressed and controlled multi candela TrueAlert ES notification appliances for extended temperature humidity range provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control unit or jumper selected as 15 WP 75 or WP 185 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each appliance allowing T tapped connections Class B circuits to simplify wiring Class A circuits require in out Self Test Mode allows on board sensors to detect the strobe and horn and then report their status to the control unit TrueAlert Device Reports at the control unit detailing appliance point custom label type and candela setting Magnet Test diagnostics to assist checkout and testing of appliances wiring Electrical test point access without removing cover Indicator and Magnet Test Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can be set to also briefly flash strobe and sound the A V horn design Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens Standard models are available with FIRE lettering or blank configured are available with additional lettering of FEU FEU FIRE ALERT This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7125 0026 0371 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Fire Protection Products Rev 5 11 2016 Mount Weatherproof Visible and Audible Visible Notification Appliances ES Diagnostics Features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test feature appliance can be confirmed without leaving the control unit Additionally each appliance LED can be selected to pulse when it receives a supervision during normal operation Details Self Test Mode from the control unit allows on board sensors depending on the device type to detect its own strobe and or horn output then report their status to the control unit Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously or individually activated by applying a magnet Appliance Magnet Test this test mode in response to the application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address Appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and the A V horn will briefly sound to indicate operation Instrument Two TSIT 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control unit Please contact your local Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring to data sheet S4905 0001 for additional information Appliance Installation 2 Appliance Installation 2 Rev 5 11 2016 and Mounting Height Reference Mount Weatherproof Visible and Audible Visible Notification Appliances 3 and Mounting Height SLC Controller Compatibility Reference 1 IDNAC SLC Controller Compatibility Reference Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply Sheet Output SLC Output Voltage SLC VDC regulated VDC 6 VDC drop 3 Rev 5 11 2016 Mount Weatherproof Visible and Audible Visible Notification Appliances Ratings 1971 1638 2 UL Listed TrueAlert ES Addressable Weatherproof Notification Appliances Selection Model numbers ending in BA are assembled in the USA V O cover separately cover separately listed weatherproof TrueAlert ES addressable requires weatherproof box see below BA indicates model is available either with without the BA suffix model numbers ending in are assembled in the USA cd or 75 cd