Simplex TrueAlert ES Addressable Notification Appliances; Wall Mount Weatherproof Notification Appliances; Visible Only (V O) and Audible Visible (A V); ULC Listed; 49WP-0002

File Preview
File Preview
Click below to download for free

Text Preview

ULC Listed Approved Addressable Notification Appliances Mount Weatherproof Notification Appliances Only V O and Audible Visible A V addressed and controlled TrueAlert ES weatherproof appliances for extended temperature humidity range provide Multi candela xenon strobe with synchronized 1 Hz rate and with intensity programmable from the panel or jumper selected as 20 30 or 75 cd Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allowing strobes to with lower current even under battery backup Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the and horn output and then report their status to the panel TrueAlert Device Reports at the control panel detailing point ID custom label type and candela see sample on page 3 Magnet Test diagnostics to assist checkout and testing appliances and wiring Electrical test point access without removing cover Indicator and Magnet Test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the Magnet pulses the LED to indicate appliance address and be set to also briefly flash the strobe and sound the horn design features include Rugged high impact flame retardant thermoplastic with clear lens Standard models are red and available with FIRE or lettering configured models are available with lettering of FEU FIRE ALERT and blank in white with each lettering Mounting is to matching weatherproof boxes required separately Separate covers are available to change application type or for replacement wiring terminals for 18 AWG to 12 AWG Enclosure is rated NEMA 3R Convenient wiring terminal access at front of housing listings reference Strobe operation is listed to ULC S526 Horn operation is listed to ULC S525 Refer to data sheet S49WP 0001 for UL listed models A V top and Strobe bottom side view of on Weatherproof Mounting Boxes right A V Models with horn Harmonically rich output sound for either coded or operation Horns sound as Temporal Code 3 March Time pattern or Temporal Code 4 controlled separately visible appliances on the same two wire circuit Selectable March Time rates of 20 60 or 120 beats per Output is or 5 dBA difference selectable the appliance or from the controller with FACP mode at the appliance ES weatherproof addressable provide visible and audible visible for indoor and outdoor extended temperature extended humidity applications They are individually and receive power supervision and control from a Simplex fire alarm control panel providing Signaling Line Circuits SLCs See list on page 4 Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Additional listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property Tyco Fire Protection Products 6 2015 ES Operation Advantage ES addressable appliances on IDNAC provide separate visible and audible notification a single two wire circuit that also confirms to the individual notification appliance circuit This operation increases circuit integrity by providing supervision that beyond the appliance wiring connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VDC voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits providing installation and maintenance savings with assurance that appliances that operate during normal testing will operate during worst case alarm Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test improves installation efficiency TrueAlert device conveniently identify information about each appliance ES Diagnostics Features When IDNAC SLCs are in diagnostic Self Test and Magnet Test features provide appliance testing With the Self Test feature operation can be confirmed without leaving the panel Additionally each appliance LED can be to pulse when it receives a supervision poll during operation Details Selecting Self Test Mode from the panel allows on board sensors depending on the type to detect its own strobe and or horn output and report their status to the control panel Operation is by VNAC appliance groups and is either automatic briefly simultaneously activated or individually by applying a magnet Refer to control panel data for more Self Test information see list on page 4 Appliance Magnet Test In this test mode in to application of a magnet the appliance LED sequentially to conveniently indicate the appliance Appliance Magnet Test In this test after the address is indicated by pulsing the appliance the strobe will briefly flash and the A V horn will sound to indicate proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert ES appliances to its to test IDCs NACs and IDNet communications connection to the control panel Please contact your Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring Refer to data S4905 0001 for additional information Intensity Product Selection Listed TrueAlert ES Addressable Weatherproof Notification Appliances Description V O cover separately cover separately listed weatherproof TrueAlert ES appliance requires weatherproof below 30 or 75 cd Covers Required when ordering 49VO APPLW CO or 49AV APPLW CO Mount Weatherproof Boxes Required VO Cover Models AV Cover Models VO Cover Models AV Cover Models Description White Mount Weatherproof Mounting Box required 5 H x 6 W x 1 D mm x 156 mm x 41 mm 6 2015 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 Weatherproof Appliance Installation Reference 1 TUE 27 Jan 15

Related Files