Simplex TrueAlert ES Audible Notification Appliances, Wall Mount Horn Strobe, Model Series 59AO

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM FM Approved Addressable Notification Appliances Wall Mount Addressable Horns Series 59AO addressable TrueAlert ES indoor and electronic horns Advanced addressable notification controlled by IDNAC providing regulated 29 VDC allow strobes on the Signaling Line Circuits SLC to operate with current even under battery backup Wiring supervision to each appliance allows connections for Class B circuits to simplify Class A circuits require in out wiring Self test mode detects the horn output and then reports status to the control panel Separate control of horns from visible appliances on same SLC with control panel selection of as Temporal Code 3 March Time as 20 60 or 120 bpm Continuous or Code 4 High and low outputs 6 dBA difference selectable the appliance or from the controller with FACP selected at the appliance Magnet test diagnostics to test appliances and wiring Listed to UL Standard 464 and ULC Standard S525 Synchronized piezo operation on the same IDNAC Indicator and Magnet Test LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the Magnet pulses the LED to indicate appliance address and selectable to also briefly sound the horn to confirm design features Rugged high impact flame retardant thermoplastic in red and white colors Various covers options are available Red with white or white with red letters Compatibility with ADA requirements Covers available in a selection of FIRE or ALERT Covers can be easily removed without disturbing the housing and avoiding trouble conditions wiring terminals for 18 AWG to 12 AWG model mounts to single gang US electrical Weatherproof model mounts to single gang electrical boxes ES 59AO series Addressable Horns are in Red with White Lettering and White with Red Lettering ES 59 Series addressable horns are addressed audible notification appliances that power supervision and control signals from a fire alarm control panel providing IDNAC SLCs ES Operation Advantage circuit integrity ES A O addressable appliances on IDNAC SLCs audible notification using a single two wire circuit also confirms connection to the individual notification electronic circuit This provides supervision that beyond the appliance wiring connections current usage on IDNAC SLCs constant 29 VDC source voltage is maintained even battery standby This allows strobes to operate at voltage with lower current and ensuring a consistent draw and voltage drop margin under both primary and secondary battery standby Efficiencies include distances up to 2 to 3 times farther than with notification support for more appliances per SLC use of smaller gauge wiring or combinations these benefits These products have been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products 09 2019 ES Operation Advantage Cont Installation and Testing Time time and expense for retrofit or new construction is reduced with separate controls on the same two wire When Class B wiring is used wiring can be tapped more savings in distance wire conduit size and and overall installation efficiency Use of Self Test Magnet Test features improves installation efficiency device reports conveniently identify information about connected appliance ES Diagnostics allows appliance operation to be confirmed without the control panel Operation is by selected VNAC groups and is automatic or individually activated by a magnet Refer to control panel data sheet for more self information see list on page 4 Indoor Product Selection TrueAlert ES Addressable Electronic Horns and cover ES Diagnostics Continued Test features indicate device location by pulsing the LED briefly and briefly sounding the horn The LED can be pulsed sequentially to indicate appliance The horn can also be briefly sounded to indicate proper Instrument Two TSIT can be used to test SLC wiring and TrueAlert ES appliances for before the appliance to the control panel Please contact local Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring See data sheet wall mounted TrueAlert ES addressable A O horn includes cover with Cover H x 3 W x 1 D 132 x 86 mm x 39 mm only Select cover separately only European adapter back plate Covers Required when ordering model 59AO APPLWR or 59AO APPLWW only Wall mounting plate for mounting to UK Deta DB164 Swiss Kaiser 9063 01 or German HSB NIS Kombi 372501686 Note BA indicates model is available either with or without the BA suffix Model numbers ending in are assembled in the USA boxes Weatherproof Product Selection TrueAlert ES Addressable Electronic Horns and cover only Select cover separately only wall mounted TrueAlert ES addressable A O horn includes cover Order surface mount weatherproof box see below with Cover H x 3 W x 1 D mm x 86 mm x 39 mm Covers Required when ordering model 59AO APPLWR O or 59AO APPLWW O Mount Weatherproof Boxes Required ordered separately Weatherproof model only only mount weatherproof single gang mounting box includes gasket and painted versions of model 7219K23 below Order your Simplex product representative mount weatherproof single gang box order blank cover to get weatherproof gasket cover with weatherproof gasket by McMaster order from electrical supplier H x 2 W x 2 D mm x 70 mm x 51 mm Note BA indicates model is available either with or without the BA suffix Model numbers ending in are assembled in the USA Cover is not used 09 2019 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 Installation and Indoor Wall Mount Height Reference AO AV H AV L AV H 1 FRI 09 May 15 Weatherproof Mounting Reference 09 2019 Output SLC Output Voltage Referenc

Related Files