Name | simplex-truealert-es-ceiling-mount-addressable-speaker-visible-notification-appliances-5089721364.pdf |
---|---|
Type | |
Size | 2.90 MB |
Downloads |
Text Preview
Datasheet Addressable Notification Appliances Mount Addressable Speaker Visible S V Notification Appliances 3 High candela appliances candela S V appliance If required select a and weatherproof box 4 High fidelity high candela appliances fidelity high candela appliance only If required a cover and surface WP separately fidelity high candela appliance with amber lens If required select cover and surface or WP box fidelity high candela appliance with blue colored If required select a and surface or WP box 5 S V covers required when ordering APPLC models FIRE ALARM logo only logo or lettering Listed FM Approved mount addressable speaker visible S V notification the Simplex fire alarm control unit FACU IDNAC signaling line SLC to individually power address and control ceiling mount S V notification appliances A separate compatible Simplex audio NAC supplies audio Electronic monitoring of wiring means you can T tap audio and IDNAC wiring for Class B reducing wiring costs and wiring distances ceiling mount addressable S V notification appliances on a 4 in 101.6 mm square 2 1 8 in 53.97 mm deep electrical provided by others for flush installations Install on a surface or backbox see Table 8 for surface or weatherproof WP are available in 400 Hz to 4000 Hz and 200 Hz to 10000 Hz fidelity models Select the appliance and cover separately to simplify ordering and installation process Model numbers ending in assembled in the USA For more information refer to datasheet 1 Ceiling mount addressable S V notification appliance mount addressable speaker product 1 Ceiling mount addressable speaker S V appliances appliance only If required a cover and surface or box separately 2 High fidelity appliances fidelity S V appliance If required select a and surface or WP box Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co S49SVC 0001 Rev 11 1 2022 Mount Addressable Speaker Visible S V Notification Appliances product selection Canada only 6 Weatherproof ceiling mount addressable S V appliances Appliance Only Select a cover and surface or WP box separately 579 1241 instructions 7 S V covers required when ordering APPLC O models mount S V specifications voltage taps response ALARM logo only 8 Surface or WP back boxes or WP back box in red or WP back box in white instructions 9 Wire guards and wire guard back boxes guard back box ceiling red WP guard ceiling red 10 Non weatherproof appliance general specifications 1 8 in H x 7 1 8 in W x 3in D 206 mm x 180 mm x 76 mm to 120 0 to 49 10 to 93 non condensing at 104 40 blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires for each terminal for wiring Use unshielded twisted pair UTP for IDNAC and audio wiring 11 Weatherproof appliance general specifications 1 8 in H x 7 1 8 in W x 3in D 206 mm x 180 mm x 76 mm temperature rating W110 CD W135 CD W185 CD to 150.8 40 to 66 temperature rating for indoor and uncontrolled wet Public Mode 110 CD to 120 0 to 49 temperature rating 40 to 120 40 to 49 humidity range 95 non condensing at 140 60 blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires for each terminal for wiring Use unshielded twisted pair UTP for IDNAC and audio wiring 12 Speaker audio specifications Vrms or 70.7 Vrms W 1 2 W 1 W and 2 W Hz to 4000 Hz S V S VH 200 Hz to 10000 Hz HF VH Signaling 125 Hz to 12 kHz 2 S49SVC 0001 Rev 11 1 2022 Mount Addressable Speaker Visible S V Notification Appliances 13 Speaker output ratings tap chamber test in accordance with UL 1480 dBA chamber test in accordance with ULC S541 dBA Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum dispersion reference in accordance with ULC S541 Anechoic Testing W dB W W W dB required output output operating voltage range voltage design reference requirements rate and synchronized SLC loading SLC loading SLC wiring specifications refer to the control unit installation for more information 14 Percentage of rated light 15 IDNAC SLC specifications below axis left right of axis VDC to 30 VDC Special Application VDC with 6 VDC drop unit load 0.8 mA control unit current Hz with up to 63 synchronized strobes maximum for each powered max 127 S V appliances for each IDNAC channel of 127 addresses for each SLC 139 unit loads See device and fire control unit installation instructions for circuit current load unshielded twisted pair recommended wire length allowed with T taps for Class B wiring for each SLC ft 3048 m wire length to any appliance 4000 ft 1219 m This can be to 8000 ft 2438 m by using a 4009 IDNAC Repeater 16 Current consumption setting and 49HFV and 49HFVH SV cd mA cd mA cd mA cd mA mA cd mA mA 110CD 305 110CD mA cd mA mA Measured at 23 VDC on IDNAC Addressable SLC are for connection to compatible fire alarm audio circuits Anechoic speaker output ratings are typically more representative of actual sound output 17 Equipment compatibility references equipment with EPS or EPS Power Supply IDNAC Repeater Flex 35 and 50 Watt Amplifiers 100 Watt Amplifiers Constant Supervision and Signal Cards sheet reference 3 S49SVC 0001 Rev 11 1 2022 mount S V installation reference Mount Addressable Speaker Visible S V Notification Appliances 2 Installation reference