Simplex TrueAlert ES Visible LED Notification Appliances, Wall Mount Multi-Candela Horn LED Strobe, Model Series 59VO 1111
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-es-visible-led-notification-appliances-wall-mount-multi-candela-horn-led-strobe-model-series-59vo-1111-5937612840.pdf |
---|---|
Type | |
Size | 13.89 MB |
Downloads |
Text Preview
TrueAlert LED Addressable Notification Appliances Notification Appliances Wall Mount Multi Candela Strobes Model Series 59VO ULC CSFM Listed FM addressed and controlled multi candela TrueAlert ES visible only notification appliances Multi candela LED strobe available in low 15 30 and 75 cd and high 135 and 185 cd range candela models Small compact design and low current draw due to energy efficient LEDs Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allows strobes to operate with lower current even battery backup Wiring supervision to each appliance allowing T tapped connections Class B circuits to simplify wiring Class A circuits require in out Self Test Mode allows on board sensors to detect the LED strobe and then report their status to the control panel TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting Magnet Test diagnostics to assist checkout and testing of appliances wiring Compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard S526 Synchronized LED strobe operation on the same IDNAC channel LED and Magnet Test Indicator and Magnet Test Indicator LED indicates magnet test acknowledgment 3 digit IDNAC and candela rating supervision Indicator LED can be configured to blink each polling cycle to indicate When the controller is in diagnostic mode the magnet test pulses the to indicate appliance address and can also briefly flash the strobe design features Rugged high impact flame retardant thermoplastic housing in red and colors Various cover and lettering options are available red with white or white with red letters Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG wiring Mounts to single gang US electrical boxes Optional mounting adapter plate to adapt to European electrical boxes 1 ES 59VO Series LED Strobes are Available in Red with Lettering and White with Red Lettering ES LED Addressable Strobes ES LED Addressable Strobes are individually addressed visible appliances that receive power supervision and control from a Simplex fire alarm control panel providing IDNAC Signaling Circuits Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA ES Operation Advantage circuit integrity ES Visual Only LED addressable appliances on IDNAC SLCs visible notification using a single two wire circuit that also connection to the individual notification appliance electronic This provides supervision that extends beyond the appliance connections current usage on IDNAC SLCs constant 29 VDC source voltage is maintained even during battery This allows strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage drop margin both primary power and secondary battery standby installation and testing time time and expense for retrofit or new construction can be reduced with separate controls on the same two wire When Class B wiring is used wiring can be T tapped allowing savings in distance wire conduit size and utilization and installation efficiency Use of Self Test and Magnet Test features installation efficiency TrueAlert device reports conveniently information about each connected appliance These products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7125 0026 0383 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Rev 3 9 2018 Notification Appliances Wall Mount Multi Candela Strobes Model Series 59VO ES Diagnostics and Magnet Test diagnostic features provide individual appliance testing for IDNAC SLCs With the Self Test feature appliance operation be confirmed without leaving the control panel Additionally each appliance indicator LED can be selected to pulse when it receives a supervision during normal operation allows on board sensors to detect strobe output on the device and report the strobe status to the control panel Operation is by selected appliance groups and is either automatic all briefly simultaneously activated or individually activated by applying a magnet Refer to control data sheet for more Self Test information see list on IDNAC SLC Controller Compatibility Reference for more information Appliance Magnet Test pulses the indicator LED sequentially in response to the application of a magnet to conveniently indicate the address Appliance Magnet Test briefly flashes the strobe to indicate proper operation after the address is indicated by pulsing the indicator Instrument Two TSIT helps with testing of IDNAC SLC wiring and TrueAlert ES appliances Use it to test IDCs NACs and IDNet before connection to the control panel Please contact your local Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring data sheet S4905 0001 for more information Selection ES LED Wall Mount Addressable Strobe Appliances 1 Appliance and cover dimensions with cover 5 H x 3 W x 1 D 132 mm x 86 mm x 39 mm rating 15 30 75 cd 110 135 and 185 cd 2 Appliance only rating 3 Separate cover 4 Separate European adapter back plate rating only mounting plate for mounting to UK Deta Swiss Kaiser 9063 01 or German HSB Kombi 372501686 back boxes Model numbers ending in are assembled in the USA Dimensions of appliance and cover 5 H x 3 W x 1 D 132 mm x 86 mm x 39 mm 2 Rev 3 9 2018 Reference Notification Appliances Wall Mount Multi Candela Strobes Model Series 59VO Plate Installation Reference SLC Controller Compatibility Reference Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply Output 5 IDNAC SLC Controller Compatibility Sheet SLC SLC Output Voltage Reference VDC regulated VDC 6 VDC drop 3 Rev 3 9 2018 Notification Appliances Wall Mount Multi Candela Strobes Model Series 59VO ES Strobe Specifications Operating Voltage Range Requirements SLC Loading Setting VDC RMS Current Ratings for typical design IDNAC Addressable SLCs 6 VDC drop cd mA 6 Electrical ratings 29.5 VDC Special Application unit load 0.8 mA control panel current of 127 addresses per SLC 139 unit loads 7 Candela setting cd mA cd mA cd mA cd cd required output output Range Range 8 Percentage of rated light output at room temperature Below Axis 9 General Specifications Left Right of Axis SLC Wiring Specifications refer to control panel installation for more information Instructions Refer to compatibility table above for fire a