Simplex TrueAlert ES Wall and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-es-wall-and-ceiling-mount-addressable-speaker-and-speaker-visible-notification-appliances-1029783456.pdf |
---|---|
Type | |
Size | 896.41 KB |
Downloads |
Text Preview
UL ULC Listed FM Approved Addressable Notification Appliances and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances speakers and speaker visible appliances are addressed and individually controlled with power and audio from a compatible Simplex fire alarm control unit A combination of an IDNAC Signaling Line Circuit SLC and a audio speaker circuit are required for these appliances ULC S541 Anechoic dBA measurements 3 m application reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the ADA application guidelines addressable wiring isolator Model 4905 9929 is available for remote mounting on addressable circuits to isolate short circuited wiring from wiring Refer to data sheet S4905 0001 for additional ES diagnostics When a controller is selected for diagnostics mode an appliance test feature can be used to perform a local test of the In silent mode the appliance LED pulses sequentially indicate the appliances address when the magnet is applied In mode the strobe flashes briefly after the address is The TrueStart Instrument TSIT can be used to test wiring and before connection to the control unit providing the installer a means to ensure wiring and appliance installation is complete control unit installation This tool also tests IDCs NACs and communications circuits Selecting Self Test mode from a compatible control unit allows in the appliances depending on the device type to detect own audio and visible output reporting that status to the control Operation is selected by VNAC groups and can be selected as all briefly simultaneously activated or individually activated applying a magnet Tests can be scheduled to occur during off times operation to limit impact during working hours and testing can be generated as needed 1 and wall mount addressable only and speaker visible strobes Separate appliances covers back boxes and wire guards provide flexibility for meeting customers installation requirements TrueAlert device reports provide important appliance information including point ID custom label type and candela setting Rugged high impact flame retardant thermoplastic housings Covers can be easily removed without disturbing the connected Terminals for wiring sizes 18 AWG to 12 AWG Appliance LED can be selected to display during each polling cycle appliance supervision Magnet test diagnostics to assist checkout and testing of appliances Compatible with the Americans with Disabilities Act ADA requirements Signalling Line Circuit SLC Advanced addressable notification controlled by IDNAC SLCs provides 29 VDC for low current operation even during battery backup Wiring supervision is electronically monitored and allows IDNAC SLC to be T tapped for Class B wiring providing flexibility in reducing sizes and or distance and reducing costs for wiring installation Strobe intensity can be selected within programming from the FACU speaker Wiring supervision is electronically monitored and allows audio wiring to be T tapped for Class B wiring providing flexibility reducing wiring sizes and or distance and reducing costs for wiring High quality voice and tone reproduction with taps for W W 1 W 2 W at 25 VRMS or 70.7 VRMS Audio speaker circuits are wired separately from IDNAC SLCs High fidelity models 200 Hz to 10,000 Hz are also available Compliant with NFPA 72 520 Hz Low frequency signal requirements for areas Listed to UL 1480 and ULC S541 UL 1480 Reverberant dBA measurements 10 ft listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co Rev 5 10 2019 mount appliance product selection 1 Wall mount S O appliances Refer to data sheet S49SOW 0001 for full product selection including covers and mounting plates and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances Series appliance only sheet reference fidelity S O appliance only 2 Wall mount S V appliances Refer to data sheet S49SVW 0001 for full selection including covers mounting plates and multi color strobe lens S O appliance only appliance only fidelity S V appliance only S V appliance only sheet reference appliance only sheet reference fidelity S O appliance only high fidelity S O appliance only mount appliance product selection 3 Ceiling mount S O appliances Refer to data sheet S49SOC 0001 for full product selection and installation requirements 4 Ceiling mount S V appliances Refer to data sheet S49SVC 0001 for full product selection and installation requirements sheet reference Canada only appliance only fidelity S V appliance only candela S V appliance only lens high fidelity high candela S V appliance only lens high fidelity high candela S V appliance only lens high fidelity high candela S V appliance only S V appliance only 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 5 10 2019