Simplex TrueAlert ES Wall Mount Addressable Speaker Notification Appliances
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-es-wall-mount-addressable-speaker-notification-appliances-3609241587.pdf |
---|---|
Type | |
Size | 992.60 KB |
Downloads |
Text Preview
UL ULC Listed FM Approved mount indoor and outdoor addressable speaker S O appliances a Simplex fire alarm control unit FACU IDNAC signaling line circuit to individually power address and control wall mount indoor addressable S O notification appliances A separate compatible FACU audio NAC supplies audio Electronic monitoring of wiring means you can T tap audio and IDNAC wiring for Class B reducing wiring costs and wiring distances wall mount indoor and addressable S O notification appliances standard 4 inch square 2 1 8 inch deep USA electrical boxes for installations provided by others or surface or weatherproof WP see Table 7 for surface or WP installations are available in 400 Hz to 4000 Hz and 200 Hz to 10000 high fidelity models Separate appliance and cover selection greatly the ordering and installation process Model numbers ending are assembled in the USA For more detailed information please datasheet S49SWC 0001 Addressable Notification Appliances Mount Addressable Speaker S O Notification Appliances 3 S O covers required when ordering APPLW models lettering ALARM only 1 Wall mount addressable notification appliance mount addressable speaker product 1 Wall mount addressable speaker S O appliances appliance only Select mounting plate and or WP box separately if 2 High fidelity appliances fidelity S O appliance Select cover mounting and surface or WP box if required Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co S49SOW 0001 Rev 9 1 2022 Mount Addressable Speaker S O Notification Appliances product selection 4 Weatherproof wall mount addressable speaker S O appliances appliance only Select cover mounting plate and surface or back box separately 5 S O covers required when ordering APPLW O models instructions lettering ALARM only 6 S O wall mount plate non weatherproof and weatherproof back plate in red back plate in white instructions 7 Surface or WP back boxes or WP back box in red or WP back box in white 8 Wire guard back box and wire guard instructions guard back box wall red WP guard wall red 2 S49SOW 0001 Rev 9 1 2022 mount speaker specifications voltage taps response Mount Addressable Speaker S O Notification Appliances 9 Non weatherproof appliance general specifications 1 2 in H x 5 in W x 1 1 2 in D or 139 mm x 128 mm x 38 mm to 120 or 0 to 49 10 to 93 non condensing at 104 or 40 blocks for 18 AWG to 12 AWG or 0.82 mm2 to 3.31 mm2 two wires for each terminal for wiring Use Unshielded Twisted Pair UTP for IDNAC and audio wiring 10 Weatherproof appliance general specifications 1 2 in H x 5 in W x 1 1 2 in D or 139 mm x 128 mm x 38 mm temperature rating private 40 to 150.8 40 to 66 and uncontrolled wet Public Mode 32 to 122 0 to 50 temperature rating 40 to 120 40 to 49 humidity range 95 non condensing at 140 60 blocks for 18 AWG to 12 AWG or 0.82 mm2 to 3.31 mm2 two wires for each terminal for wiring Use Unshielded Twisted Pair UTP for IDNAC and audio wiring 11 Speaker audio specifications VRMS or 70.7 VRMS W 1 2 W 1 W and 2 W Hz to 4000 Hz S O 200 Hz to 10000 Hz H F signaling 125 Hz to 12 kHz W tap Chamber Test per UL 1480 dBA Chamber Test per ULC S541 dBA dB 12 Speaker output ratings 25 Vrms or 70.7 Vrms at 10 ft or 3 m W W 13 Polar dispersion reference per ULC S541 anechoic chamber testing dB W 14 IDNAC SLC specifications operating voltage range voltage design reference consumption at 23 VDC on IDNAC addressable SLC requirements SLC loading VDC to 30 VDC special application VDC with 6 VDC drop mA unit load 0.8 mA control unit current SLC wiring specifications refer to the unit installation instructions for more of 127 addresses for each SLC 139 unit loads See device and compatible Fire Alarm Unit Installation Instructions for circuit current load limits unshielded twisted pair recommended wire length allowed with T Taps for Class B wiring for each SLC 10,000 ft or 3048 m wire length to any appliance 4000 ft or 1219 m This can be doubled to 8000 ft or m by using a 4009 IDNAC Repeater 3 S49SOW 0001 Rev 9 1 2022 compatibility reference equipment with EPS or EPS Power Supply IDNAC Repeater Flex 35 and 50 Watt Amplifiers 100 Watt Amplifiers Constant Supervision and Audio NACs mount S O installation reference Mount Addressable Speaker S O Notification Appliances sheet reference rear mount height reference terminals and connection clips for speaker and connections accept two 12 18 AWG wires in X 4 in electrical backbox 2 1 8 in deep to 4 in X 4 in X 2 1 8 in electrical box using 8 32 can remove the appliance and cover from the back using a slotted or philips head screwdriver 2 Installation reference Wall Mount Back Plate test location in or 152 mm minimum 72 requires the top of audible appliance to be 90 in above the finished floor and not less that 6 in the ceiling confirm with your local codes audio circuit voltage and power tap here Dip Switch a unique address for the appliance through an eight DIP switch ADDR1 on the rear of the appliance 2022 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co Simplex the product names listed in this material are marks or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 9 1 2022