Simplex TrueAlert ES Weather Proof Audible Visible LED Notification Appliances, Wall Mount Multi-Candela Horn LED Strobe, Model Series 59WP

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Approved LED Addressable Notification Appliances Notification Appliances Wall Mount Only Audible Visible Model Series 59WP Individually addressable multi candela TrueAlert ES notification appliances Multi candela LED strobe available in low 15 30 and cd and high 110 135 and 185 cd range candela Available in Visible Only V O and Audible Visible Small compact design and low current draw due to energy Strobe intensity can be programmed from the control models strobe LEDs or the device Advanced addressable notification controlled by IDNAC Line Circuits SLCs provides regulated 29 which allows strobes to operate with lower current under battery backup Wiring supervision to each appliance allows connections for Class B circuits to simplify Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the and or horn output and then report their status to control panel TrueAlert Device Reports at the control panel detail point ID custom label type and candela see sample on page 3 Magnet Test diagnostics assist checkout and testing of Synchronized LED strobe and piezo operation on the and wiring IDNAC channel listings reference Meets environmental requirements for UL1638 and light requirements for UL1971 UL 1638 listed for outdoor applications UL 1971 listed for indoor applications indoor are compatible with ADA requirements to important mounting information on page 3 Horn operation is listed to UL Standard 464 Strobe operation listed to UL Standard 1971 and ULC S526 Indicator and Magnet Test LED indicates magnet test acknowledgment digit IDNAC address and candela rating LED can be configured to blink on every cycle to indicate appliance supervision When the controller is in diagnostic mode the magnet pulses the LED to indicate appliance address and also briefly flash the strobe Models with horn Horns controlled separately from visible appliances on same two wire circuit Selectable March Time rates of 20 60 or 120 BPM Output is or 5 dBA difference at the appliance or from the controller ES 59WP Series LED Addressable Strobes are in Red with White Lettering and White with Red design features Rugged high impact flame retardant thermoplastic in red with white letters or white with red letters Various covers options are available red with white or white with red letters Available with English and Arabic FIRE lettering Surface mounts to a single gang weatherproof electrical Covers can be easily removed without disturbing the housing and avoiding trouble conditions wiring terminals for 18 AWG to 12 AWG ES 59 Series weatherproof addressable provide visible only and audible visible for indoor and outdoor extended temperature extended humidity applications They are individually and receive power supervision and control from a Simplex fire alarm control panel IDNAC LED and xenon tube strobes require operation on IDNAC channels Application Reference selection of visible notification is dependent on location local codes and proper applications of National Fire Alarm Code NFPA 72 ANSI A117.1 appropriate model building code BOCA ICBO or and the application guidelines of the Americans Disabilities Act ADA These products have been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are the of Tyco Fire Protection Products 9 2016 ES Diagnostics Continued TrueStart Instrument Two TSIT can be used to test SLC wiring and TrueAlert ES appliance IDC NAC IDNet communications before connection to the control Please contact your local Simplex representative for information Addressable Wiring Isolator Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring See data sheet for more information ES Diagnostics Magnet Test allows individual appliances to be tested when SLCs are in diagnostic mode allows selected devices to detect their own strobe horn output and then report their status to the control Operation is by selected VNAC appliance groups and is or individually activated by applying a magnet Appliance Magnet Test pulses the appliance LED sequentially in response to an applied magnet conveniently indicate the appliance address Appliance Magnet Test indicates device by pulsing the indicator LED briefly and then flashes strobe LEDs and sounds the horn to indicate proper Product Selection ES 59 Series Weatherproof Appliances surface mount box and gasket Dimensions with cover 5 H x 3 W x 1 D 132 mm x 86 mm x 39 mm BA Only Only rating 15 30 and 75 Red White rating rating Red White rating White weatherproof covers Required when ordering appliance only models 110 135 and 185 cd White rating rating Mount Weatherproof Boxes Required ordered separately only only Only Surface mount weatherproof single gang mounting box includes weatherproof and painted versions of Model 72219K23 below Order from your Simplex representative See install instructions 579 1224 for more information mount weatherproof single gang mounting box blank cover below to get matching weatherproof by order electrical product H x 2 W x 2 D mm x 70 mm x 51 cover is not used European adapter back plate Blank cover with weatherproof gasket back boxes Black Wall mounting plate for mounting to UK Deta DB164 Swiss Kaiser 9063 01 or German HSB NIS Kombi Note BA indicates model is available either with or without the BA suffix Model numbers ending in are assembled in the USA 9 2016 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report

Related Files