Simplex TrueAlert Multi-Candela Notification Appliances; Visible Notification Appliances with Synchronized Flash; Non-Addressable, SmartSynch Operation Compatible
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
UL ULC CSFM Listed FM MEA NYC Multi Candela Notification Appliances Notification Appliances with Synchronized Flash Non Addressable SmartSync Compatible 1 Mount Strobes 2 Mount Strobes only V O 24 VDC notification appliances with high output strobe available for wall or ceiling mount Intensity is selectable as 15 30 75 or 110 candela with visible jumper secured behind strobe housing Operation is compatible with ADA requirements refer to Installation Surface or Semi Flush Wall Mounting Polarized input allows connection to compatible reverse polarity notification appliance circuit NAC Regulated circuit design ensures consistent flash output and provides inrush current Rugged high impact flame retardant thermoplastic housings are in red or white with clear lens Listed to UL 1971 and ULC S526 NEMA 1 rated See Product Selection for more information provide synchronized flash for use with Simplex fire alarm control panels with NACs selected to provide strobe or SmartSync two wire control 4009 IDNet NAC Extenders Separate strobe Synchronization Modules that are available for Class B Class A operation Separate SmartSync Control Modules SCMs that provide Class B or A output from conventional NAC inputs housings provides flexible easy and convenient semi or surface wall mounting Rear of housing does not extend into box Wall mount strobes easily mount to single gang double gang or 4 inch outlet box Ceiling mount strobes mount to single gang boxes mount strobe features Wiring terminals are accessible from the front of the housing providing access for installation inspection and testing Covers are available separately to convert housing color adapters and wire guards Wall mount strobe adapters are available to cover surface mounted boxes and to adapt to 2975 9145 boxes UL listed red wire guards are available for wall or ceiling mount TrueAlert synchronized strobes provide convenient to standard electrical boxes The enclosure designs are both and vandal resistant and provide a convenient strobe intensity Since each model can be selected for intensity output on model inventory is minimized and changes encountered during can be easily accommodated mount strobe housings are a one piece assembly including lens mounts to a single or double gang or 4 square standard electrical The cover can be quickly removed a tool is required and covers are separately for color conversion mount strobes install using standard single gang electrical Color choice is determined by model number Intensity Selection installation a selection plug at the back of the housing the desired strobe intensity An attached flag with black on a highly visible yellow background allows the selected intensity be seen at the side of the strobe lens Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA Strobes Strobes When multiple strobes and their reflections can be from one location synchronized flashes reduce the probability photo sensitive reactions as well as the annoyance and possible of random flashing These multi candela strobes are over a two wire circuit when connected to compatible to compatible Synchronized Flash Modules or to SmartSync Modules Two Wire Control applications desire the audible notification appliances to be of being silenced before the alarm condition is reset on until while the visible notification appliances are kept activated until alarm condition is reset on until reset SmartSync operation mode this function using a single circuit two wire operation Control Sources two wire control is available from 4007ES Hybrid 4008 4010 4010ES 4100ES and 4100U Fire Control Panels refer to individual product data sheets for more IDNet NAC Extenders refer to data sheet S4009 0002 Control Module SCM Model 4905 9938 refer to data sheet SmartSync compatible notification appliances include horns and combination horn strobe notification appliances more information refer to installation instructions 579 548 Rev 6 01 2020 Notification Appliances with Synchronized Flash Non Addressable SmartSync Operation Compatible Selection 1 Multi Candela Visible Notification Appliances Strobes NEMA 1 rated when used with 4095 9931 adaptor plate and 2975 9145 back box Color white red white red white red white red 2 Wall Mount Strobe Adapters strobe with intensity selectable as 15 30 75 or 110 synchronized flash rate SmartSync two wire control compatible Red Adapter Plate for mounting to Simplex 2975 9145 box typically for retrofit Mount Adapter Skirt use to cover 1 1 2 38 mm deep surface boxes be mounted vertical or horizontal Red Mounting Box requires Adapter Plate 4905 9931 H x 5 1 4 W x 1 5 8 D 136 mm x 133 mm 41 mm Total depth with strobe 4 3 8 111 x 5 3 4 x 0.060 Thick 211 mm x 146 x 1.5 mm x 5 1 8 x 2 3 4 D 200 mm x 130 mm x 70 NEMA 1 rated 3 Ceiling Mount Strobe Adapter Mount Adapter Plate zinc plated required for mounting to handy box not when using 4905 9926 guard x 3 1 8 x 0.060 D 124 mm x 79 mm x 1.5 4 Synchronization Modules refer to data sheet S4905 0003 for additional information B A Control Module with Class B or Class A output mounts in 4 102 mm box Flash Module epoxy encapsulated with in out 18 AWG mm2 wire leads rated for 2 A NAC requires 5 mA for power x 2 7 16 x 13 16 35 mm x 62 mm x 20 x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 cover with white FIRE lettering cover with red FIRE lettering mount mount UL listed by Space Age Electronics Inc 5 Replacement Covers and Guards Wall mount strobes wire guard with mounting plate compatible with semi or surface mounted boxes H x 5 W x 1 1 2 D 130 mm x 127 mm x mm H x 6 1 16 W x 3 1 8 D 154 mm x 154 x 79 mm x 4 3 8 x 2 7 8 deep 156 mm x 111 mm 73 mm 2 Rev 6 01 2020 Notification Appliances with Synchronized Flash Non Addressable SmartSync Operation Compatible Specifications Voltage Range Rate NAC Loading Range Range Dimensions with lens RMS Current Rating per Strobe see Note 2 below RMS Currents at voltages Dimensions with lens RMS Current Rating per Strobe see Note 2 below RMS Currents at voltages VDC VDC VDC VDC 6 Wall Mount or Ceiling Mount Common Specifications 24 VDC see Note 1 below Hz to 35 synchronized strobes maximum per NAC to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for in wiring H x 5 W x 2 3 4 D 130 mm x 127 mm x 70 mm cd mA mA mA L x 2 5 16 W x 2 5 8 D 121 mm x 75 mm x 67 mm cd mA mA mA cd mA mA mA cd mA mA mA cd mA mA mA cd mA mA mA cd mA mA mA cd mA mA mA 24 VDC refers to the voltage range of 16 to 33 VDC per UL Standard 1971 Signaling Devices for the Hearing Impaired This voltage is the absolute operating range Operation outside of this range may cause permanent damage to the strobe Please note that 16 VDC is lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions The maximum RMS current listed