Simplex TrueAlert Non-Addressable S V, Round Ceiling Mount

File Preview
File Preview
Click below to download for free

Text Preview

CSFM Listed FM MEA NYC Approved Notification Appliances Speaker Visible Notification Appliances with TrueAlert Strobe Round Ceiling Mount ceiling mount notification with Multi tapped speaker High intensity xenon strobe selectable for free run or flash notification appliance speaker High quality voice and tone reproduction with taps for 1 2 1 or 2 W at 25 or 70.7 VRMS Speakers are wired separately from strobe wiring UL listed to Standard 1480 Compliant with NFPA 72 520 Hz Low Frequency Requirements for Sleeping Areas non addressable visible notification strobe Models available with 15 30 or 110 candela 24 VDC operation with switch selection for free run synchronized flash rate UL listed to Standard 1971 Compatible with ADA requirements Strobe candela rating is clearly indicated on reflector Rugged high impact flame retardant thermoplastic flash rate mode for use with Synchronization modules for Class B Style Y or A Style Z operation appliance design provides Round housing for ceiling mount in standard boxes Separate in out wiring terminals for speaker and non addressable speaker visible S V appliances combine a multi tapped and a high intensity strobe to provide audio tone and visible notification from the same and strobes are wired separately The speaker is with taps available for either 25 VRMS or VRMS and the strobe is selectable for either free run synchronized operation Mount TrueAlert Non Addressable S V Appliances White Housings with Red Lettering Selection selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Operation non addressable S V strobes can be set free run operation or synchronized operation using an selection switch When selected for synchronized flash operation is controlled from Simplex Fire Alarm Control Panels providing NACs to product Simplex strobe synchronization refer to control panel data sheet for details Synchronized Flash Modules 4905 9914 Class B 4905 9922 Class A IDNet NAC Extender models 4009 9201 and refer to data sheet S4009 0002 This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this Accepted for use City of New York Department of Buildings MEA35 93E product was not ULC listed as of document revision date Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection 5 2014 Round Ceiling Mount Notification Appliances with TrueAlert Non Addressable Strobes Output Rating cd cd Color with red lettering encapsulated with in out AWG 0.82 mm2 wire leads for 2 A NAC requires mA for power W x 2 7 16 L x 13 16 H mm x 62 mm x 20 mm diagram on page 4 102 mm square 1 1 2 38 mm deep with 1 1 2 extension by others Product Selection cd Flash Control Modules Synchronized Flash Module B Style Y operation Synchronized Flash Module A Style Z operation Bridge Installation Reference input terminals and tap selection are from rear of housing switch for free run or flash is behind strobe determine operation inserting into housing 5 2014 S V Specifications Specifications Voltage Range Listed Range Regulated 24 VDC see Notes 1 below Listed Range 20 VDC to 30 VDC per ULC S526 M87 Hz with up to 35 synchronized strobes maximum per NAC Rate and Synchronized NAC Loading RMS Current Rating per Strobe see Note 2 below Currents other voltages VDC VDC cd mA mA mA cd mA mA mA cd mA mA mA Specifications Voltage Taps Alarm Frequency Response or 70.7 VRMS see Note 3 below 1 2 1 and 2 W to 4000 Hz Output dBA 10 ft 3 m Tap 1480 Reverberant Rating W W W W Specifications Dimensions including lens into Box Tap Selection Range Range Instructions H x 5 W x 2 5 8 D 184 mm x 127 mm x 67 mm 57 mm jumper wire with pressure connector attaches to one of 8 terminals to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 separate terminals for and strobe connections 24 VDC refers to the voltage range of 16 to 33 VDC per UL Standard 1971 Signaling Devices for the Impaired changes effective May 1 2004 This voltage range is the absolute operating range Operation outside this range may cause permanent damage to the appliance Please note that 16 VDC is the lowest operating voltage is allowed at the last appliance on the NAC under worst case conditions The strobe of this A V is field selectable for or synchronized operation The maximum RMS current listed is the device nameplate rating Strobe designs are constant wattage and the maximum current rating occurs at the lowest allowable operating voltage RMS is root mean square and refers to the value of a varying current waveform Speakers are for connection to conventional fire alarm audio circuits 5 2014 2905 9946 Tile Bridge mm diameter 6 mm 4 places 95 mm square centered on plate thick sheet folded with lip each side mm mm 602 mm SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Code are registered trademarks of the National Fire Protection Association NFPA 2014 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 5 2014

Related Files