Simplex TrueAlert Notification Appliances; SmartSync 2-Wire Operation, Non-Addressable Multi-Tone Horns

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM current 24 VDC Simplex SmartSync electronic multi tone provide the following features A selection of tones for each appliance including Horn Slow Whoop Siren and 500 Hz Horn The 500Hz horn tone is not compliant with NFPA 72 Low Fre Signal Requirements for Sleeping Areas Output level selectable as standard or high Rugged high impact flame retardant thermoplastic housings available red with white FIRE lettering or white with red FIRE lettering Diode polarized input for connection to reverse polarity supervised control Notification Appliance Circuits NACs two wire control of audible and visible notification provides the following functions Control of horn and bell tones as Temporal Pattern March Time or on continuously controlled separately from visible on the same circuit Slow Whoop Siren and High or Low tone selections sound their tones synchronized to each other when receiving SmartSync commands SmartSync March Time pattern produces a 60 BPM output for the 500 Hz Horn and the Bell tone Visible appliances on the same circuit operate at a synchronized 1 Hz rate See SmartSync control sources for the SmartSync control list See selection for additional operation information notification appliance design provides flexible easy convenient semi flush or surface wall mounting Easily mounts to single gang double gang or 4 in square electrical box In and out wiring terminals 18 AWG to 12 AWG Rear of housing does not extend into box accessories Mounting adapters to cover surface mounted electrical boxes and to to Simplex 2975 9145 boxes UL listed wire guard UL ULC listed sound damper for locations requiring attenuation of 5 to dBA such as stairwells small rooms or highly reverberant areas Covers are available separately to change color or for replacement reference Listed to Standard 464 Listed to Standard S525 Notification Appliances Two Wire Operation Non Addressable Multi Tone Horns 1 multi tone horns are available as with red lettering or as red with white lettering non addressable multi tone horns These horns provide flexible selection of output tones for fire alarm audible notification See 6 for tone output details Tone Selection DIP Switch selection determines the local tone A separate DIP Switch position allows selection of a standard or a output sound level selectable appropriate to the location See Table for sound output ratings mounting Multi tone horns can be semi flush or surface on a standard single gang double gang or 4 in square or mm electrical box Optional accessories are available to increase and application flexibility two wire control operation mode allows a two wire circuit to provide the ability activate both the horn and strobe on the same NAC and then allow horn to be silenced while the strobe remains flashing The horn as On until silenced while the strobe operation is On until control sources two wire control is available for the following models 4006 4007ES Hybrid 4008 4010 4010ES 4100ES and 4100U Fire Control Units FACUs Refer to individual product data sheets for information 4009 IDNet NAC Extenders refer to data sheet S4009 0002 SmartSync Control Module SCM Model 4905 9938 Refer to data S4905 0003 See Table 4 for guard listing This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 4 11 2019 Two Wire Operation Non Addressable Multi Tone Horns selection White Lettering non addressable multi tone H x W x D 1 8 in x 5 in x 1 1 2 in mm x 127 mm x 38 mm 1 Product selection 2 Sound damper and adapters Sound Damper package of 20 field installed adhesive backed horn output reduces output 5 to 6 dBA After Sound Damper installation measure sound level to ensure compliance with code requirements mount red adapter skirt mount white adapter skirt to cover 1 1 2 in surface mounted Plate red for mounting to Simplex 2975 9145 box for retrofit may be mounted vertical or horizontal mounting box requires Adapter Plate 4905 9931 H x W x D 3 4 in Diameter 44.5 mm 0.31 in 8 mm sound opening 3 8 in x 5 1 4 in x 1 5 8 in mm x 133 mm x 41 mm depth with horn 3 1 8 in 79 mm 5 16 in x 5 3 4 in x 0.060 in Thick mm x 146 mm x 1.5 mm 7 8 in x 5 1 8 in x 2 3 4 in mm x 130 mm x 70 mm Control Module Class A or Class B installs in 4 in square box 3 Synchronization control module H x W x D in x 4 1 8 in x 1 1 4 in 102 mm x 105 mm x mm 4 Covers and guard horn cover with white FIRE lettering horn cover with red FIRE lettering wire guard with mounting plate compatible with semi flush or surface boxes H x W x D 1 8 in x 5 in x 1 1 2 in 130 mm x 127 mm x 1 16 in x 6 1 16 in x 3 1 8 in 154 mm x 154 x 79 mm UL listed by Space Age Electronics Inc 2 Rev 4 11 2019 Two Wire Operation Non Addressable Multi Tone Horns horn specifications 5 Multi tone horn specifications voltage range current range range VDC to 33 VDC mA to 122 or 0 C to 50 to 93 non condensing at 100 or 38 blocks for 18 AWG to 12 AWG 0.82 mm to 3.31 mm two wires for each terminal for in and out wiring Hz horn Whoop or Low to 3700 Hz sweep modulated at Hz rate dBA Hz modulated at 7 ms intervals dBA Hz tone Hz to 1200 Hz sweep dBA Hz to 1200 Hz 1 sec on then repeat 67 dBA dBA tones of 1000 Hz and 800 Hz ms duration dBA at 30 off axis dBA at 50 off axis 6 Multi tone sound output characteristics output ratings for each UL 464 chamber test at 10 ft or 3 m output dBA output dBA Output Ratings per ULC S525 Chamber test at 3 m or 10 output High output dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA each ULC testing UL output ratings below 75 dBA are for NFPA 72 Private Mode applications ULC output ratings below 85 dBA are for use in applications for each applicable local code Horn Bell and 500 Hz Horn are controlled by SmartSync commands to produce Temporal Pattern March Time Pattern or Continuous The 500Hz is not compliant with NFPA 72 Low Frequency Signal Requirements for Sleeping Areas Horn 500 Hz Horn and Bell provide a 60 BPM March Time Pattern when receiving the SmartSync March Time command Slow Whoop Siren and High orLow tones are for use with SmartSync Continuous commands As with the horn and bell tones they are synchronized the controlling SmartSync timing commands allowing synchronization across multiple NACs plate installation information 2 adapter plate installation information 3 Rev 4 11 2019 reference additional information refer to 4901 TrueAlert Non Addressable Wall Mount Multi tone Horn Installation Instructions 579 869 Two Wire Operation Non Addressable Multi Tone Horns 3 or semi flush multi tone horn mounting 4 view of multi tone horn with surface mount adapter 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 4 11

Related Files