Simplex TrueAlert Notification Appliances; SmartSync Control Module and Strobe Synchronization Modules

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Notification Appliances SmartSync Control Module and Synchronization Modules conventional Notification Appliance NACs into SmartSync circuits or strobe circuits Simplex SmartSync Control Modules combine horn and strobe NAC inputs into a 2 wire that can silence horns while maintaining strobe operation Synchronized Flash Modules provide a 2 wire strobe output that also operates 24 VDC conventional reverse polarity appliances Control Module SCM provides control to separately activate horns and Operation allows and on the same two wire pair while supervision continuity SmartSync horns sound as Temporal or March pattern or continuous controlled separately strobes on the same circuit Strobes on the same circuit operate at a 1 Hz flash rate Output is either Class B or Class A strobe synchronization models Encapsulated package with color coded wire leads 1 Hz strobe synchronization and maintains continuity Conventional horns and other DC appliances on the same 2 wire circuit Models are available with Class B or Class A Small size allows convenient mounting listed to Standard 1971 These products have been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listing and 7125 0026 235 for allowable values and or conditions concerning presented in this document Accepted for use City of New York Department of MEA35 93E Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Fire Protection Products SmartSync Control Module SCM Approximately 1 2 Size Class A Synchronized Flash Module Approximately 1 2 Size SmartSync Control Module SCM 4905 9938 SCM SmartSync Control Module two conventional NAC inputs into a SmartSync NAC output One NAC can be programmed to as and would be designated as horn control non coded on continuously during A second NAC would be programmed to provide operation and would be for the visible strobe control also non coded on during alarm Power is supplied by the control NAC Horn output and Synchronized In addition to operating the strobe and the horn the SCM can be switch selected to operate horns as temporal coded march time coded beats minute or on continuously Strobes are with 1 Hz synchronized flashes 11 2014 Additional SCM Features Mode Up to eight SCMs can be interconnected synchronize system notification Interconnected SCMs are for proper circuit connection The horn input NAC the Multi Sync function NAC Inputs Both NAC inputs are isolated each other and can be supplied from different panels B Style Y and Class A Style Z output are both supported fault detection is provided by the strobe control during supervision mode additional information refer to Installation 574 719 Synchronized Flash Modules 4905 9914 and 4905 9922 add the required to activate Simplex synchronized strobes for that do not provide that control Conventional or other compatible 24 VDC notification appliances the same circuit ignore strobe synchronization and when the NAC is in alarm additional information refer to Installation 579 232 Product Selection SmartSync Control Module Class A Class B output Details 4 x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 mm in 4 102 mm square box Class B Synchronized Flash Module Dimensions 1 3 8 x 2 7 16 x 13 16 D 35 mm x 62 mm x 20 mm Class A Synchronized Flash Module encapsulated with 8 203 mm in out 18 AWG 0.82 mm2 wire rated for 2 A NAC requires 5 mA for power Adapter plate to fit 4 11 119 mm square electrical box Specifications Specifications to 122 F 0 to 50 C Range Range to 93 non condensing at 100 F 38 C SmartSync NAC Modules for use with SmartSync compatible appliances Voltage Range Ratings VDC to 33 VDC with a maximum ripple of 2 V peak to peak A maximum can be wired as Class A or Class B to 35 maximum SmartSync appliances with strobes to 40 maximum SmartSync horn only appliances NAC current plus 30 mA 24 VDC for SCM operating power mA 24 VDC Control NAC Input Current Control NAC Current A Operation Mounting Requirement Mount SCM within 20 ft 6 m of control panel use metal conduit 4905 9922 Synchronization Modules Voltage Range VDC to 33 VDC A maximum output requires 5 mA for power to 35 maximum strobes per synchronized circuit in control panel or separate 4 51 mm square electrical box 1 1 2 mm minimum depth Ratings 11 2014 NAC Capability Reference Panels NAC Source 4007ES Hybrid 4008 4010 4100ES and 4100U Series Fire Control Panels and IDNet NAC Extenders Series 4003 4004 4005 4100 4020 4001 4002 Control Panels Series Signal ZAMs 4009 Series NAC Extenders Reference Output Module Required Function A or Class B Strobe Synchronization none A or Class B SmartSync operation reverse polarity NACs modules are required to control strobes and or SmartSync for Class B synchronized strobes for Class A synchronized strobes for SmartSync control Control Module provides Class A or Class B SmartSync operation B Strobe Synchronization Module A Strobe Synchronization Module Compatible Simplex Appliance Reference Refer to specific appliance data sheets for additional compatibility and product information Type mount set for SmartSync operation mount SmartSync operation only mount SmartSync operation only Horn Hz Tone Wall mount set for SmartSync operation Horn Hz Tone Wall mount set for SmartSync operation 49CMT WWF 49CMT APPLW mount synchronized also SmartSync compatible mount selectable for synchronized also SmartSync operation compatible mount horn and strobe can be wired 4 wire strobes are selectable for flash mount SmartSync operation only Multi Tone Multi Tone mount SmartSync operation only case wall mount horn and strobe be wired separately 4 wire strobes are for synchronized flash Hz Wall mount SmartSync operation Hz Wall mount SmartSync operation mount SmartSync operation only mount SmartSync operation only mount strobes are selectable for flash mount strobes are selectable for flash case wall mount strobes are for synchronized flash

Related Files