Simplex TrueAlert Notification Appliances, Speaker Visible Notification Appliance with TrueAlert Non-Addressable Strobe, Selectable as Free-Run or Synchronized
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
Notification Peripherals Notification Appliance with TrueAlert Non Addressable Strobe Selectable Free Run or Synchronized selection selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA operation non addressable S V strobes can be set for free run or synchronized operation using an on board selection switch selected for synchronized operation flash operation is controlled Simplex Fire Alarm Control Units providing NACs selected to Simplex strobe synchronization signals refer to control unit sheet for details Synchronized Flash Modules 4905 9914 Class B or 4905 9922 A 4009 IDNet NAC Extender models 4009 9201 and 4009 9301 refer data sheet S4009 0002 ULC CSFM Listed Approved MEA NYC notification appliance with multi tapped speaker high intensity xenon strobe details High quality voice and tone reproduction with taps for 1 4 W 1 2 W 1 or 2 W at 25 VRMS or 70.7 VRMS Capacitor input for connection to supervised notification appliance Speakers are wired separately from strobe wiring Compliant with NFPA 72 520 Hz Low Frequency Signal Requirements Sleeping Areas Non Addressable visible notification appliance Models available with 15 75 or 110 candela 24 VDC operation with switch selection for free run or synchronized rate Listed to UL 1971 and ULC S526 Compatible with ADA requirements Refer to Installation references Strobe candela rating is clearly indicated on reflector Rugged high impact flame retardant thermoplastic housing available red or white covers are available separately to convert color UL listed red wire guard is available for surface or semi flush mounting appliance design provides Flexible easy and convenient flush or surface wall box mounting Separate in out wiring terminals for speaker and strobe 18 AWG to 12 non addressable speaker visible S V notification combine a multi tapped speaker and a high intensity strobe provide audio tone notification and visible notification from the same and strobes are wired separately The speaker is multi tapped taps available for either 25 VRMS or 70.7 VRMS and the strobe is for either free run or synchronized operation 1 Appliances are available in red white lettering and white with red lettering This product was not ULC listed or approved by FM MEA NYC or CSFM as of document revision date Additional listings may be applicable contact your local product supplier for the latest status and approvals under Time Recorder Co are the property of Tyco Safety Products Westminster Rev 8 3 2020 Notification Appliance with TrueAlert Non Addressable Strobe Selectable as Free Run or Synchronized selection Wall Mount Notification Appliances with TrueAlert Non Addressable Strobes 1 Red with white FIRE lettering 2 White with red FIRE lettering output rating cd cd cd output rating cd cd cd 3 Mounting adapters and boxes mount red adapter skirt mount white adapter skirt when mounting to surface electrical box 4 in square 1 2 in deep with 1 1 2 in deep Plate red required to mount S V on 2975 9145 box red for surface or flush mount requires adapter plate this box may be available for retrofit applications 4 Synchronized flash control modules 3 4 in H x 5 3 8 in W x 3 3 16 in or 197 mm x 137 mm x 81 mm with S V 5 7 8 in or 149 mm 5 16 in H x 5 3 4 in W x 0.060 in or 211 mm x 146 mm x 1.5 7 8 in H x 5 1 8 in W x 2 3 4 in D 200 mm x 130 mm x 70 mm 3 8 in W x 2 7 16 in L x 13 16 in or 35 mm x 62 mm x 20 mm encapsulated with in out 18 or 0.82 mm2 wire leads rated 2 A NAC requires 5 mA for power to data sheet S4905 0003 additional flash control module 5 Covers and guard covers are for replacement or color conversion S V cover with white FIRE lettering S V cover with red FIRE lettering guard with mounting plate red compatible surface and semi flush boxes UL listed by Age Electronics Inc 1 4 in H x 5 in W x 1 3 8 in D or 184 mm x mm x 35 mm 3 8 in H x 6 1 16 in W x 3 1 4 in D or 213 mm 154 mm x 79 mm Flash Module Class B Style Y operation Flash Module Class A Style Z operation 2 Rev 8 3 2020 Notification Appliance with TrueAlert Non Addressable Strobe Selectable as Free Run or Synchronized references 2 reference 3 Rev 8 3 2020 Notification Appliance with TrueAlert Non Addressable Strobe Selectable as Free Run or Synchronized Red adapter skirt 4905 9946 white adapter skirt 4905 9947 Conduit knockouts are provided on all four sides 3 mounting reference specifications voltage range rate and synchronized NAC loading RMS current rating for each strobe output see 2 below currents at other VDC VDC 6 Strobe specifications 24 VDC see note 1 below Hz with up to 35 synchronized strobes maximum for each NAC cd mA mA mA 7 Speaker specifications cd mA mA mA cd mA mA mA voltage taps alarm frequency response output ratings VRMS or 70.7 VRMS see note 3 below W 1 2 W 1 W and 2 W Hz to 4000 Hz W dBA W dBA dBA dBA tap Chamber per UL 1480 10 3 m Chamber Test ULC S541 3 m ft W dBA dBA W dBA dBA Polar Dispersion Reference per ULC Anechoic Chamber Testing dB 30 off axis dB 55 off axis 4 Rev 8 3 2020 Notification Appliance with TrueAlert Non Addressable Strobe Selectable as Free Run or Synchronized dimensions including lens into box tap selection range range instructions 8 General specifications 3 4 in x 6 7 8 in x 2 5 8 in D or 121 mm x 175 mm x 67 mm 3 4 in or 70 mm jumper wire with pressure connector attaches to one of 8 terminals to 122 or 0 to 50 to 93 non condensing at 100 or 38 for 18 AWG to 12 AWG or 0.82 mm2 to 3.31 mm2 separate for speaker and strobe connections 24 VDC refers to the voltage range of 16 VDC to 33 VDC per UL Standard 1971 Signaling Devices for the Hearing Impaired This range is the absolute operating range Operation outside of this range may cause permanent damage to the appliance Please note that VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions The strobe of this A V is field for free run or synchronized operation The maximum RMS current listed is the device nameplate rating Strobe designs are constant wattage and the maximum RMS current rating at the lowest allowable operating voltage RMS is root mean square and refers to the effective value of a varying current waveform Speakers are for connection to conventional fire alarm audio circuits 5 Rev 8 3 2020 Notification Appliance with TrueAlert Non Addressable Strobe Selectable as Free Run or Synchronized 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 8 3 2020