Simplex TrueAlert Notification Appliances, Visible Notification Appliances for Free-Run Operation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealert-notification-appliances-visible-notification-appliances-for-free-run-operation-3481256907.pdf |
---|---|
Type | |
Size | 761.90 KB |
Downloads |
Text Preview
UL ULC Listed FM CSFM MEA NYC Approved VDC powered xenon flashtube visible appliance strobe for wall mounting UL listed to Standard 1971 Models are available with 15 75 or 110 candela Strobe candela rating is clearly indicated on reflector Compatible with ADA requirements refer to important information on page 2 Diode polarized input for connection to reverse polarity notification appliance NAC wiring is accessible from front of housing easy access for installation inspection and Regulated circuit design ensures consistent output Rugged high impact flame retardant thermoplastic available in red or white Covers are available separately to convert housing color notification appliance design provides easy and convenient semi flush or wall mounting Easily mounts to single gang double gang or 4 inch outlet box wiring terminals for 18 AWG to AWG wire Rear of housing does not extend into box adapters and wire guard Mounting adapters are available to cover surface electrical boxes and to adapt to Simplex boxes UL listed red wire guard is available for semi flush or mounting This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation for use City of New York Department of Buildings MEA35 93E Additional may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Safety Products Westminster Notification Appliances Notification Appliances Free Run Operation Non Addressable Strobes are Available in Red White Lettering and White with Red Lettering non addressable free run strobes quick and convenient installation using a flexible design The strobe housing is a rugged assembly including lens that mounts to single double gang or 4 square standard electrical box terminals are accessible from the front of the providing easy access for installation inspection testing The cover can be quickly removed a tool is and when in place the entire assembly is impact vandal resistant Separate covers are available for conversion Selection selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA 9 2004 Product Selection Visible Notification Appliances Strobes Number Output Rating cd cd cd Color mount red adapter skirt mount white adapter skirt to cover 1 1 2 deep mounted boxes plate red for mounting to Simplex 2975 9145 Box for retrofit may be mounted vertical or horizontal mounting box requires Adapter Plate 4905 9931 and Guard cover with white lettering cover with red lettering UL listed by Space Age Electronics Inc Semi Flush or Surface Strobe Mounting with white lettering with red lettering H x 5 1 4 W x 1 5 8 D mm x 133 mm x 41 mm depth with strobe 111 mm x 5 3 4 x 0.060 Thick mm x 146 mm x 1.5 mm x 5 1 8 x 2 3 4 Deep mm x 130 mm x 70 mm H x 5 W x 1 1 2 D mm x 127 mm x 38 mm guard with mounting plate red compatible with semi flush or mounted boxes H x 6 1 16 W x 3 1 8 D mm x 154 mm x 79 mm is compatible with gang double gang and 102 mm square boxes 38 mm deep by others access hole terminals WALL MOUNT HEIGHT REFERENCE of lens either even or slightly bottom compatible outline Holes square 4 gang 2 gang 3 2.03 m 72 requires the entire lens not less than and not greater 96 above the floor housing lens assembly cover required 9 2004 Specifications Specifications Voltage Range Range Range Specifications Rate Currents other voltages Listed Range Regulated 24 VDC see Note 1 below Listed Range 20 VDC to 30 VDC per ULC S526 M87 Dimensions including lens H x 5 W x 2 3 4 D 130 mm x 127 mm x 70 mm to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two per terminal for in out wiring RMS Current Rating per Strobe Output Note 2 below Hz cd mA mA mA VDC VDC cd mA mA mA cd mA mA mA 24 VDC refers to the voltage range of 16 to 33 VDC per UL Standard 1971 Signaling Devices for the Impaired changes effective May 1 2004 This voltage range is the absolute operating range Operation outside this range may cause permanent damage to the appliance Please note that 16 VDC is the lowest operating voltage is allowed at the last appliance on the NAC under worst case conditions The maximum RMS current listed is the device nameplate rating Strobe designs are constant wattage and the maximum current rating occurs at the lowest allowable operating voltage RMS is root mean square and refers to the value of a varying current waveform Installation Reference Adapter Plate Guard and Adapter Skirt Box Mounting Reference Optional Adapter Skirt Optional Wire Guard mount conduit and shown for reference 102 mm square profile 1 1 2 mm deep Guard Adapter Plate Adapter Plate Optional Wire Guard here for reference only be used on other mounting options Surface Mount Adapter Skirt deep 4905 9937 Red White conduit knockouts provided on all four sides 9 2004 Simplex the Simplex logo and TrueAlert are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries NFPA 72 and National Fire Code are registered trademarks of the National Fire Protection Association NFPA 2004 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 9 2004