Simplex TrueAlert Text Messaging Appliances; LED Text Messaging Appliance with Addressable Message Selection

File Preview
File Preview
Click below to download for free

Text Preview

OBSOLETE FOR REFERENCE ONLY ULC CSFM Listed NYC Acceptance Text Messaging Appliances Text Messaging Appliance with Addressable Selection using IDNet Communications Text Messaging Appliance Illustration with Sample Message visibility multi color LED text message provides visible textual alarm notification from compatible Simplex fire alarm panels During alarm conditions up to 32 pre programmed selections can be activated in response to emergency situations or linked to specific point status conditions Text messages provide textual alarm notification for of high noise or with other audibility limitations Text messages can duplicate a broadcasted audible or can provide more local detail per the Communication Systems Mass Notification UL listed to Standard 1638 Textual Visible Appliance listed to S527 Miscellaneous Ancillary Device to ULC message note requirement on page 3 with the 4007ES 4010 4010ES and 4100U Series fire alarm control panel IDNet communications communications format emulates 4009 IDNet Extender 4009A controls for easy interfacing 4007ES 4010ES 4100ES and 4100U IDNet SLCs line circuit can control up to 25 message with up to ten 10 4009 IDNet NAC Extenders 4010 IDNet SLCs control up to five 5 total of either type message presentation area provides long wide area 140 viewing Dual line 2.3 58 mm high messages provide typical distance of up to 100 ft 30.5 m Single line 4.7 119 mm high messages provide viewing distance of up to 200 ft 61 m LEDs are multi color red yellow green to emphasize content Words can be upper or lower case standard bolded or expanded with selectable sizes Messages can be static flashing or scrolling with a of appearance transition options communications control provides Up to 32 available messages 10 factory messages are included message details Advise of proper evacuation routes relocate to a secure take action due to severe weather conditions in place or other facility specific actions New messages can be created factory pre programmed can be modified if needed Please note that the creation and modification of alarm may trigger code mandated retesting of the alarm system and should be performed by authorized personnel non alarm messages can be on site using optional TrueAlert Messenger software requirements Message board is powered by listed fire alarm power providing 24 VDC with battery backup typically by host control panel features Standard message board includes fixed brackets for wall and also includes 100 mm VESA Video Standards Association mounting holes for with listed wall or ceiling VESA mounting bracket Optional wall mount adjustable brackets allow rotation where required for improved viewing Optional mounting box secures to wall surface or can also mount with 100 mm VESA bracket Ceiling mounting is available by cable suspension to top mounted eyehooks optional operation mode Message boards can also display non alarm information local LAN Ethernet connection using separate software that is overridden during an Alarm or condition refer to details on page 2 and ULC on page 3 Additional message input options are available contact local Simplex product representative for details Control panels will override non alarm messages upon they can also be programmed to blank the display local power failure to conserve batteries This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 324 allowable values and or conditions concerning material presented in this document It is to re examination revision and possible cancellation Accepted for use City of New Department of Buildings MEA35 93E This product was not approved by FM as of revision date Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Fire Protection Products 11 2014 Description Text Messaging Appliances Audible appliances and are commonly used to provide notification of alarm typically to signal the need for building However when the required response is to defend in place or provide detailed information Text Messaging Appliances display custom text with the instructions required per the local communication systems mass notification plan Mode When alarm conditions occur the fire alarm overrides optional non alarm messaging and selects programmed messages pre determined to be appropriate the reported conditions In multiple alarm situations up 8 messages can be displayed in sequence Mode Optional During non alarm bulletin board messages can be scrolled for information distribution This information is Product Selection to the Messaging Appliance via LAN local area network if optionally connected connection can be used or left unconnected Failure Mode The host fire alarm panel can be such that during a local power failure the message is sent to reduce battery standby In the event of an alarm condition during failure the panel will use its battery backup to power the appliance and display the appropriate Control Process The compatible fire alarm panel activates the Messaging Appliances by IDNet communications commands similar to used to control the 4009 IDNet NAC Extender include control of up to 8 NACs and with NAC capable of up to 4 different control modes in a total of 32 commands available to select messages and or the blanking control Messaging Appliance in dark gray housing supplied with fixed mounting brackets for wall mounting holes for VESA bracket mounting or for ceiling cable mounting Adjustable Swivel Mount Brackets 2 to allow wall mounted appliance to be tilted down where desired Ethernet Cable 15 ft long 4.6 m connect for non fire alarm messaging input Mounting Box lightweight aluminum painted dark gray 30 5 16 W x 6 3 4 H x 1 3 8 D shipped with for attaching messaging appliance refer to details on page 4 messaging software allows site specific messages such as time weather announcements menus to be delivered during system idle time and is overridden during an Alarm or Alert condition For details your local Simplex product supplier or email SimplexSales InovaSolutions com Factory Pre Programmed Messages Message top line is yellow bottom is scrolling red except as noted Line Fixed Bomb Threat sec sec sec in sec sec sec Clear sec sec sec Voice Line Scroll emergency has been reported in the building Please proceed to the nearest and vacate the building Line Scroll emergency has been reported in the building Please secure your area and for further instructions Line Fixed Hostile Intruder Line Fixed Shelter In Place Line Scroll emergency condition has been reported Secure your windows and doors remain in the building Unsafe conditions may exist outside You will be when further information is available Line Scroll emergency condition has been discovered in the building Proceed to your exit and vacate the building Line Fixed Evacuate Alt Line Fixed Weather Alert Line Scroll severe weather warning has been issued Proceed to the designated shelter and wait for further instructions Line Scroll green Attention please the emergency condition has been cleared may return to your normal activities Line Scroll fire has been reported in the building Proceed to the nearest exit and vacate building Report to your designated assembly place outside the building

Related Files