Simplex TrueCom Building Communication Systems, 5105-Series Controller
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truecom-building-communication-systems-5105-series-controller-3617085294.pdf |
---|---|
Type | |
Size | 726.92 KB |
Downloads |
Text Preview
Communications Systems Controller to the administrative phone port using the Administrative Phone with Display for instant identification especially important for emergency The 5105 has been designed to interface with in house phone systems without the need for interface modules In most applications the phone system will access the 5105 system via one of it outside line ports start trunk port required The 5105 station are directly coupled to the program and intercom eliminating conventional transformer losses frequency limitations and provides a much clearer for talk back modes This ensures system reliability any shorted circuit only affects the one group of all other system speaker groups remain Controller Features Cost effective Solid State Intercom Expandable to 96 Stations Privacy and Pre announce Tones are User Telephone Paging to Multiple Paging Zones or All Easy Operation Compatible with Existing Phone Customer Configured via Software optional Optional Direct Architectural Room Dialing One Administrative Phone Port with Emergency Port Time tone Signaling Optional Enhance Feature Card Add on Simplex 5105 is a high performance micro processor Building Communications System It can be for one way two way group call and all functions to speaker circuits using electronic technologically advanced design of the 5105 uses no mechanical switches eliminating electrical mechanical problems Electronic switching allows and intercom function via a Touch tone phone simple commands basic 5105 9001 system is factory configured to communications ability for up to 24 locations If the system can be easily enlarged by adding cabinets accommodating groups of 24 stations a combined total of 96 stations basic 5105 system speaker circuits are pre assigned group call bins consisting of six speakers per group dial codes enabling the user to connect to multiple combinations All Call paging is also available Basic 5105 System 5105 has provision for one Administrative phone port an overriding emergency All Call page port Any touch tone telephone can be used on either of ports A microphone and contact may also be used the emergency page port instead of a telephone Calls any of the system call in stations are routed to the phone for two way communications Three priority levels are possible low Stations 21 24 normal and emergency Basic Caller ID CLID of a pre assigned two or three digit number is Controller Base Unit intercom station has the ability to place normal or calls Normal calls are placed by pushing the button once emergency calls are initiated by four button pushes Stations 21 24 have the ability to programmed priority These four stations also a relay contact associated with them to facilitate door latch operation When a call is initiated one of these four stations the attendant presses the key twice to unlock the door This feature is especially in applications where access to building facilities to be monitored and controlled 3 02 ID display Enhanced CLID showing name location of caller Time sync output available Four user defined page groups Riot mode emergency call operation only Programmable class of service call buttons Normal call Normal Emergency call Emergency only 1 4 digit Architectural Room numbering plan Auxiliary serial port for PC programming tool Real time clock for time tone schedule functions Six user defined event schedules Up to 256 events maximum One schedule event active at any one Time sync output Optional Modem Package Allows programming changes via from remote location requires to C O Line or PBX station the basic and enhanced 5105 has the capability of the optional 5105 9202 external battery back up system operation during a power failure Paging operation during a power failure helps to ensure safety of a building occupants during an emergency situation One back up unit is required per 24 Basic or Enhanced 5105 systems up to six can linked allowing All Call paging or Emergency paging to be transmitted to more than one In a multi building location one 5105 system phone can be designated as the global master with all other 5105 systems having local capabilities only with master override 5105 Administrative Phone has a 20 call queue calls are placed at the top of the queue by normal then low priority calls In the event Administrative station is handling calls emergency will cause a distinctive triple signal in the phone as as the calling speaker while normal and low priority cause a double signal The attendant simply presses to answer the next call in the queue 5105 system is capable of playing background music speakers not involved in hands free communications or one way page The groups of speakers to receive the source are determined by dip switch settings during installation Typical applications for this feature warehouse and factory areas where background is desired paging is accomplished via the administrative by dialing the specific code associated with a pre page group Multiple page groups can be accessed by first dialing the serial page code followed by the desired page group codes To an All Call page the administrator dials the All Call code 5105 has the capability of and functions The attendant makes a group or All Call and waits for their called party to respond The party can then press any of the system call twice to be connected to the attendant To the caller initiates the Follow Me function by another call switch twice The individual is then to the attendant from his her new location uses for these features include store and warehouse areas Ability to locate key employees that may anywhere in your facility at a given time when you to communicate with them is an important element any business time tone may be externally or internally generated and through the system speakers An external clock is required for selecting time tone schedules the basic 5105 Work and Cleanup schedules can be broadcast to employees basic 5105 has provisions for adding a printer to log call activities basic 5105 functions are programmed by circuit board settings or the 5105 9101 Enhancement can purchased Enhanced 5105 System optional 5105 9101 Enhanced Feature Card is By adding this feature card all 5105 functions programmed using a Microsoft Windows based basic 5105 functions are available under the enhanced as well as the following features Time and Date available to printer output Time and Date available for administrative phone S5105 0001 4 3 02 Administrative Phone with Caller ID Requirements Operating Voltage 120 240 VAC Current 1.0A 120 VAC 0.5 A 240 VAC Frequency 50 60 Hz Inputs Emergency Tone Input Ground Activated Input Impedance 10 kW Input Level 10 dBm Time Tone Input Input Impedance 10 kW Input Level 10 dBm Printer Port Serial Type Baud Rate 9600 8 Data Bits No Parity 1 Stop Bit Temperature 0 to 40 C Humidity 0 85 Non precipitating Environment Dimensions Base Unit 19 H x 10 3 4 W x 3 3 8 D Expander Unit 19 H x 8 3 4 W x 3 3 8 D Optional Equipment illustrations that follow show some of the optional available for the 5105 TrueCom systems Integration 5105 is easily integrated with premise Key and PBX systems When integrated with the Sim