Simplex TrueCom Building Communications System AOR Remote Call Station

File Preview
File Preview
Click below to download for free

Text Preview

Detect360 Emergency Communications System Call Station ends and Features Audible and visual status indicators Two way voice communication Talk and listen confirmation tones Omnidirectional microphone Durable 16 gauge steel construction Powder coat finish Large red call button Automatic supervision at command panel Supervision test key Detect360 Emergency Communications System Call Station provides both audible and visual to the caller After the call button is the yellow sent LED on the illuminates and an audible confirmation tone issued every few seconds until the call has been at the command panel After the call is the LED indicator switches off the is established ECS Remote Call Station features a green connectivity LED that blinks every minute visual assurance of network connectivity The station is supervised by the TCOM CP2000 Communications System Command Additionally the supervision for each station be manually tested using the test key on the face of the unit When the key switch activated the associated button icon for the station illuminated on the command panel display ECS Remote Call Station housing is made of vandal resistant 16 gauge steel The hinged plate is secured with tamper proof screws ECS Remote Call Station can be surface or It features an integral back box for mount installation An optional TCOM Remote Call Station Flange is available for installation installation guidance please refer to 579 1260 ECS Remote Call Station Installation Call Station textured powder finish includes surface mount box connectors 2 tamper proof cover and tamper proof driver bit only for surface mount of Emergency System Call Station Selection Current Temp Height Distance 39 mA Standby 15 mA 74 mA Box 8.0 W x 6.5 H x 3.0 D mm x 165 mm x 76 mm Flange Trim 9.25 W x 8.5 H mm x 216 mm lbs 1.5 kg F to 120 F 0 C to 49 C 93 rel humidity at 90 F 32 C using appropriate 10 fasteners no higher than 48 1.2 m above finished flor for a forward reach and 1.27 m for a side reach to the Americans with Disabilities Accessibility Guidelines for more maximum of 31 remote call stations be per command Please refer to the ECS for stations distance power calculations twisted pair FPLP solid or unshielded One twisted pair AWG for 24v power and one twisted 18 AWG for communication must be installed in accordance NFPA 72 two hour fire rated wiring requirements Contact field engineering for guidance 8 18 Remote Call Station Flange ECS Remote Call Station Installation Wiring Reference product names listed in this material are marks and or registered marks Westminster MA 01441 U S A use is strictly prohibited sheets may change without further notice 8 18

Related Files