Simplex VESDA-E VEP IDNet Aspirating Smoke Detectors with IDNet Communications

File Preview
File Preview
Click below to download for free

Text Preview

UL CSFM Listed Detection Products VESDA E VEP IDNet Aspirating Smoke Detectors with IDNet Communications Simplex VESDA E VEP IDNet series of smoke detectors use advanced technology to provide early warning and nuisance alarm to a wide range of applications Built on the Flair detection and years of application experience VEP detectors perform over their lifetime through absolute calibration VEP aspirating smoke detector with onboard IDNet communications Compatible with Simplex 4007ES 4010ES and 4100ES fire alarm units FACU IDNet communications added to the VESDA E VEP aspirating smoke Communicates status information and receives commands from the FACU detection technology is the revolutionary detection chamber that forms the core of VESDA E VEP providing higher stability and increased longevity It better detection and fewer nuisance alarms with direct imaging the sampled particles using a CMOS imager combined with multiple commissioning and operation the VESDA E VEP aspirator you can use of a total of 427 ft 130 of sampling pipe in the one pipe model and 1,542 ft 470 m of in the four pipe model Out of the box operation is possible with which initiates airflow normalization Xtralis ASPIRE and VSC applications fully support the VEP for easy pipe network design commissioning and maintenance You can initiate the AutoLearn and Flow from the VSC host FACU operations include the following Initiate detector reset Request standby mode Request disable mode Airflow normalization Silence detector host FACU information received includes the following Four alarm states alert pre alarm action pre alarm fire 1 and fire 2 Urgent fault status minor fault status and standby status Analog values for smoke obscuration percentage and detector fault devices communicate on VESDAnet a bi directional network that provides continued redundant operation during single point wiring failures VESDAnet enables centralized control maintenance and monitoring reference UL FDA FCC CSFM 1 Simplex VESDA E VEP IDNet detector LEDs one pipe 4098 VEP A00 1P 2 Simplex VESDA E VEP IDNet detector 3.5 in display four pipe 4098 VEP A10 P Simplex VESDA E VEP IDNet series of aspirating smoke detectors a range of features that provide user value including the One pipe and four pipe models are available for different applications Flair detection technology for reliable early warning in a wide range of with minimal nuisance alarms Multi stage filtration and optical protection with clean air barriers for detection performance Four alarm levels and a wide sensitivity range for optimum protection the widest range of applications An intuitive LCD icon display providing instant status information for response maintenance Flow fault thresholds for each port accommodating varying airflow A smart onboard filter retains dust count and remaining filter life for An extensive log of up to 20,000 events for analysis and system AutoLearn smoke and flow for reliable and rapid commissioning Ethernet for connectivity with Xtralis software for configuration monitoring and maintenance USB port for PC configuration and firmware upgrade using a memory Two pre configured GPIs one monitored for flexible remote control Field replaceable sub assemblies for faster service and maximum These products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7259 0026 0508 for values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection Products S4098 0056 Rev 2 03 2022 VESDA E VEP IDNet Aspirating Smoke Detectors with IDNet Communications VEP 3.5 in display reference 3 VESDA E VEP 3.5 in display 1 Display symbol reference and alarm threshold levels 2 1 OK fault fault fault fault fault chamber fault fault module fault 2 S4098 0056 Rev 2 03 2022 VESDA E VEP IDNet Aspirating Smoke Detectors with IDNet Communications 2 VESDA E VEP VEP specifications VEP A A lbs 4.59 kg A A A A A A lbs 4.49 kg sq ft 2,000 m2 ft 280 m ft 470 m pipe ft 110 m Auto Pipe Clean pipes ft 100 m pipes ft 80 m pipes ft 70 m VEP VDC to 30 VDC 24 V nominal 0.53 A alarm 0.57 A A A A A A lbs 4.49 kg sq ft 1,000 m2 ft 95 m ft 130 m pipe ft 95 m l m voltage current Current consumption at 24 setting quiescent in alarm coverage length linear length branched lengths depending number of pipes in of holes airflow for pipe Active Add W x H x D conditions design tool A in x 8.9 in x 5.3 in 350 mm x 225 mm x 135 mm 32 to 100 0 to 38 air 4 to 140 20 to 60 see note 5 to 95 RH non condensing External diameter 1 in or 25 mm 3 4 in IPS External diameter 1 in or 25 mm 3 4 in IPS through adaptor pre configured relays non latching states rated 2 A at 30 VDC resistive to the FACU Direct connection to the IDNet loop through recommended wiring rating access termination connection from card terminal block range range setting range 1.02 in 26 mm cable entries terminal blocks 24 AWG to 14 AWG 0.2 mm2 to 2.1 mm2 AWG to 14 AWG 0.75 mm2 to 2.5 mm2 obs ft to 10 obs ft 0.000 obs m to 32 obs m obs ft to 6.25 obs ft 0.005 obs m to 20 obs m 0.0016 obs ft to 0.625 obs ft 0.005 obs m to 2.0 obs m 0.0016 obs ft to 0.625 obs ft 0.005 obs m to 2.0 obs m 0.0031 obs ft to 0.625 obs ft 0.010 o bs m to 2.0 obs m 0.0063 obs ft to 6.25 obs ft 0.020 obs m to 20.0 obs m log with up to 20,000 events level user actions alarms and faults with time and date stamp learns alarm thresholds and flow fault thresholds by monitoring the environment features The sampled air temperature reaches detector ambient temperature upon entry into the detector Refer to Xtralis design guides and application for sampled air pre conditioning 3 S4098 0056 Rev 2 03 2022 VESDA E VEP IDNet Aspirating Smoke Detectors with IDNet Communications or revision 3 IDNet communications compatibility reference addressable communications with communications circuit isolated from input power and communications communications source and 4010ES FACUs FACU Main System Subordinate 2 w IDNet2 Extended System Subordinate ESS NAC Power Supply NACPS IDNAC Power Supply IDNAC 2 2 IDNet base address through Xtralis VSC Software For four pipe systems the next sequential are automatically assigned firmware 6.02.02 or higher revisions of firmware selection and ordering information

Related Files