Solidyne M2V Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name solidyne-m2v-data-sheet-9041835762.pdf
Type PDF
Size 785.16 KB
Downloads

Text Preview

M2V VAV Controller Document 3 01 2005 Cont Environment 40 to 140 F 4 to 60 C 10 90 Relative noncondensing Storage Temperature 10 to 150 F 23 to 66 C Storage Humidity 0 95 Relative noncondensing Communication RS 485 3 conductor 18 guage shielded up to 8000ft max Rate selectable 57.6k 38.4k 19.2k 9600 2400 1200 Backup 7 year lithium Dimensions 70 mm 2.75 in 78 mm 3.0 in 160 mm 6.3 in Holes 148.5 mm 5.85 in Center to Center 1.2 lb Approvals Device Pending Air Volume Controller M2V is the next generation Variable Air and Temperature Controller Plug in modules available for flow sensing actuator and external control These plug in modules allow easy of the M2V for any type of VAV This peer to peer stand alone or VAV controller can control ANY type of air volume unit Requirements Inputs Temperature Temperature Zone Temperature Setpoint Adjust ZTS A Main Damper Actuator Position Auxiliary Damper Actuator Position Temperature Inputs are 3k 10k 100kohm thermistor Type 3 Outputs Actuator Output 0 10vdc Actuator Output 0 10vdc Can drive down to 10Kohm loads at 10vdc Voltage 23 to 28 VAC 50 60 Hz 1.7 VA without optional plug in modules 10.3 VA all optional plug in modules used Voltage Fuse Resetable fuse rated at 1.1A at 24VAC is in the process of UL CSA approval for the entire M2 family and associated modules Please use Solidyne UL number E76576 24G9 for all references to agency approvals REV 3 01 2005 Solidyne Corporation 4215 Kirchoff Rd Rolling Meadows IL 60008 800 648 3980 www solidyne com MODULE M2 R4 M2V FMD M2V FMD HOT NEUTRAL RS 485 LAN COMM CONNECTION RS 485 LAN COMM CONNECTION RS 485 LAN COMM CONNECTION TEMP COMMON TEMP 3 10 100K INPUT 2 COMMON TEMP 3 10 100K INPUT 1 ADJUSTMENT POT INPUT 3 TRANSDUCER POWER 25mA MAX VDC INPUT OUTPUT COMMON VDC INPUT INPUT 8 VDC OUTPUT OUTPUT 3 VDC INPUT INPUT 7 VDC OUTPUT OUTPUT 1 T R ON CFM SENSOR PORT SWITCH ON HEARTBEAT LED JUMPER M2V FS MODULE TYPE 10K 100K 10K 100K 1 2 3 4 5 6 7 8 TEMP AIR DAMPER DAMPER 0 10V TABLE BLOCK 9 AIR 10 15 13 BOARD BOARD BOARD BOARD BOARD OUTPUT TABLE MODULE 0 10V BOARD BOARD OUTPUT TABLE OUTPUT 1 MAIN ACTUATOR CW 2 ACTUATOR MODULE 3 AUX ACTUATOR CW 4 AUX ACTUATOR CCW 5 6 7 8 OUTPUT OUTPUT OUTPUT OUTPUT FUTURE USE FUTURE USE MUST HAVE 8 PIN RJ 45 TO PROPERLY CONNECT M2V SIDE TERMINAL DU 1 ALSO HAVE BEEN PURCHASED NOV 2004 HAS INTERNAL TEMPERATURE THAT SHARES THE SAME AS TEMP SENSOR 1 DU 1 AND TEMP TERMINAL CANNOT BE SIMULTANEOUSLY Installation Notes sure that BATT JUMPER is place before powering unit with on board POWER unit is powered ON LED flash 1 second on 1 off continuously when is operating This flashing as a heartbeat and that the unit on It will not flash or when unit is off inserting or removing modules or display such as DU 1 M2V must powered OFF or damage will OUT M and OUT AUX share same output number as MAIN ACTUATOR output 1 and AUX CW output 3 from the plug in cards yet they can used simultaneously since OUT M and OUT AUX are 0 type outputs and the ACTUATOR CW and AUX CW are digital types is internally protected over current by a 1.1 self resetting fuse will protect the 24VAC powering the M2V being damaged due to the failing internally 8v output is used for low power Solidyne

Related Files