Solidyne sLON-1x Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name solidyne-slon-1x-data-sheet-8530612497.pdf
Type PDF
Size 758.63 KB
Downloads

Text Preview

TECH DATA SHEET Controller sLON 1 Controller is an interoperable controller in accordance with LONMARK guidelines loaded with a pre engineered application from WPT Software Tool application library or using WPT Software Tool these provide control for packaged rooftops heat fan coils unit ventilators and similar This controller features sLON WTSx sensor support one digital input one universal and three digital outputs This controller in standalone mode or as part of a network using the integral FT 3150 Free communications transceiver A direct to a sLON ADPx Communication adapter a PC with WPT Software Tool is necessary to and modify applications Chart Controller with Coil Profile 8020 Controller with Pump Profile Controller with Profile 8030 Controller with Profile 8030 Digital Input DI Universal Inputs UI Digital Outputs DO items not provided carton for damage If notify carrier Inspect for damage upon must be a technician Job wiring diagrams Corporation www solidyne com rev1 02 2005 Tools Digital Volt ohm meter DVM Drill and bits for mounting screw Static protection wrist strap Class 2 power transformer supplying a nominal 24 VAC 20.4 to 30 VAC with a rating of 12 VA 50 60 Hz per controller plus Digital Output DO Each DO be up to an additional 24VA maximum In European Community transformer must to EN 60742 Terminators One sLON T1 terminator required for each free topology segment Two sLON T2 terminators required for each bus topology segment Two 10 sheet metal screws rev1 02 2005 Electrical shock hazard Disconnect power before installing or removing the Follow Static precautions when installing this equipment Use copper conductors that are suitable for 167 75 Make all connections according to electrical wiring diagram national and local electrical Precautions charges damage electronic components The microprocessor and associated circuitry extremely sensitive to static discharge Use the following precautions when installing or operating the system Work in a static free area Discharge static electricity by touching a known securely grounded object Use a wrist strap connected to earth ground when handling the controller printed board Communications Commission FCC equipment has been tested and found to comply with the limits for a Class B digital pursuant to Part 15 of the FCC Rules These limits are designed to provide protection against harmful interference in residential installations This generates uses and can radiate radio frequency energy and may cause harmful if not installed and used in accordance with the instructions Even when are followed there is no guarantee that interference will not occur in a particular If this equipment causes harmful interference to radio or television reception can be determined by turning the equipment off and on user is encouraged to to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Connect the equipment to an outlet on a circuit different from that to which the receiver the separation between the equipment and receiver connected Consult the dealer or an experienced radio television technician for help Department of Communications DOC class B digital apparatus meets all requirements of the Canadian Interference Causing Regulations Community Directives equipment meets all requirements of European Community Directives for Low Voltage General Safety 92 59 EEC and Electromagnetic Compatibility Avoid locations where excessive moisture corrosive fumes vibration or explosive are present Avoid electrical noise interference Do not install near large contactors electrical or welding equipment Locate where ambient temperatures do not exceed 140 60 or fall below 40 and relative humidity does not exceed 95 or fall below 5 non condensing sLON 1 controllers are suitable for indoor use only rev1 02 2005 controllers can be mounted in any direction and on any plane Mounting dimensions shown in Figure 1 shown in inches mm Mounting Dimensions following electrical connections can be made to sLON 1 controllers Sensor Link S Link connection to an sLON WTS Sensor sLON WTSx LONWORKS network LON connection connections including One Universal Input UI One Digital Input DI Three Digital Outputs DO Figure 2 for wiring terminal information Power connection to a 24 VAC nominal Class 2 EN 60742 power source and earth rev1 02 2005 Input to 5 Vdc to 20mA Thermistor Balco Platinum Input Dry Input Contact one Sensor Network 3150 Transceiver Controller LEDs Service Pin Button Outputs Vac Class 2 VA per output Duty A Pole Single Throw Open Relay Power Vac 50 60 Hz 2 VA per Controller DO Loads detect a closed switch maximum resistance must be less than 300 ohms detect an open switch minimum resistance must be greater than 1.5K ohms signals of 1 to 11 Vdc must be converted to 0.45 to 5 Vdc with a voltage AD 8961 220 Applications which use 0 to 20 mA analog inputs require a 250 ohms shunt resistor kit Install resistor across universal input and common Applications which use a 10K Thermistor Sensor universal input require an 11K ohms resistor kit AD 8969 206 Install resistor across universal input and common To detect an open switch minimum resistance must be greater than 100K ohms sLON 1 Terminal Connections rev1 02 2005 Wiring Communication wire pairs must be dedicated to sLON WTSx S Link and LONWORKS LON communications They cannot be part of an active bundled telephone Shielded cable is not required for S Link or LON wiring the cable is installed in areas of high RFI EMI the cable must be in conduit shielded wire is used the shield must be connected to earth ground at one end only a 470K ohm 1 4 watt resistor Shield must be continuous from one end of the trunk the other wiring includes a connection between the controller and a sLON WTS via the S Link and a connection between the controller and the LONWORKS Network An optional LONWORKS Network connection between the controller and one sLON Sensor is also possible Figure 2 shows S Link and LON wiring terminations Link S Link Wiring wiring powers and enables the sLON WTS sensor The S Link needs at least 24 0.51mm twisted pair voice grade telephone wire The capacitance between cannot be more than 32 pF per foot 0.3m If shielded cable is used the between any one conductor and the others connected to the shield cannot be than 60 pF per foot 0.3m Maximum wire length is 200 ft 61m Controller supports one sLON WTS Sensor sLON WTSx S Link wiring is polarity insensitive conduit is used between an sLON WTS Sensor and a controller the LONWORKS and S Link wiring can be in the same conduit however they must be separate S Link wiring can be in the same conduit with UI and DI Wiring Network LON Wiring approved category 4 or 5 twisted pair cable may be used for both connecting to the network and the optional LONWORKS network connection between the controller sLON WTS sensor LONWORKS network wiring is polarity insensitive Do not mix with UI DI DO or power types of wiring If cond

Related Files