Solidyne sLON-V1, V2 data sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | solidyne-slon-v1-v2-data-sheet-5210876394.pdf |
---|---|
Type | |
Size | 974.82 KB |
Downloads |
Text Preview
TECH DATA SHEET VAV Controller sLON V1 and sLON V2 VAV Controllers are LONMARK variable air volume These controllers provide pressure control for cooling and reheat They feature a built in actuator with over damper mounting an integral velocity transducer LED indication support for an digital sensor push button manual mechanical position indication and an easy mechanical travel limit They function in mode or as part of a LonWorks network the integral FTT 10 Free Topology transceiver A direct connection to a Communication adapter and a PC with Software Tool software is necessary to download modify applications Chart Inputs Outputs Type Floating denotes LONMARK VAV Variable Air Volume profile and profile version Cooling Series Fan Induction Parallel Fan None Staged Electric Time Reheat None Occupancy Satellite Corporation www solidyne com sLON V2x rev1 03 2005 items not provided carton for damage If damaged notify carrier immediately Inspect controllers for Return damaged products must be a qualified technician Job wiring diagrams Tools AM 340 T 25 Torx short arm key L shaped wrench or T 25 Torx bit with 1 4 in hex shank for use with socket wrenches 1 4 inch hex driver for travel adjustment screws Pliers for turning damper shafts Digital Volt ohm meter DVM Drill and bits for mounting screw Static protection wrist strap Torque wrench capable of measuring at least 32 in lb 0.37 Kg meters AM 135 3 8 in 9.5mm to 1 2 in 12.8mm shaft adapter optional Class 2 power transformer supplying a nominal 24 Vac 20.4 to 30 Vac with a minimum of 12 VA 50 60 Hz per controller plus Digital Output DO loads Each DO can be to 24 VA In European Community transformer must conform to EN 60742 Terminators One sLON T1 terminator required for free topologies Two sLON T2 terminators required for bus topologies One 10 sheet metal screw 0.170 in 17 100 I D FRPE polyethylene tubing or 0.125 in 1 8 I D or 0.25 in 1 4 tygon tubing for piping connections Not more than five feet 1.52m long Electrical shock hazard Disconnect power before installing or removing the Follow Static precautions when installing this equipment Use copper conductors that are suitable for 167 75 Make all connections according to electrical wiring diagram national and local electrical Precautions charges damage electronic components The microprocessor and associated circuitry extremely sensitive to static discharge Use the following precautions when installing or operating the system Work in a static free area Discharge static electricity by touching a known securely grounded object Use a wrist strap connected to earth ground when handling the controller printed board Communications Commission FCC equipment has been tested and found to comply with the limits for a Class B digital pursuant to Part 15 of the FCC Rules These limits are designed to provide protection against harmful interference in residential installations This generates uses and can radiate radio frequency energy and may cause harmful if not installed and used in accordance with the instructions Even when are followed there is no guarantee that interference will not occur in a particular If this equipment causes harmful interference to radio or television reception can be determined by turning the equipment off and on user is encouraged to to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Connect the equipment to an outlet on a circuit different from that to which the receiver the separation between the equipment and receiver connected sLON V2x rev1 03 2005 Consult the dealer or an experienced radio television technician for help Department of Communications DOC class B digital apparatus meets all requirements of the Canadian Interference Causing Regulations Community Directives equipment meets all requirements of European Community Directives for Low Voltage General Safety 92 59 EEC and Electromagnetic Compatibility sLON V2x rev1 03 2005 controllers are for indoor use only Avoid locations where excessive moisture corrosive fumes vibration or explosive are present Avoid electrical noise interference Do not install near large contactors electrical or welding equipment Locate where ambient temperatures do not exceed 131 55 or fall below 32 and relative humidity does not exceed 85 or fall below 5 non condensing location must clear the maximum dimensions of the controller case and allow the to be mounted flush to the surface of the terminal box and perpendicular to the shaft controllers directly over the damper shaft in any direction and on any plane that is to the damper shaft Mounting dimensions are shown in Figure 1 terminal boxes have sheet metal screw heads or other protrusions near the damper In these cases a spacer or shim may be added under the mounting tab of the actuator make the actuator perpendicular to the shaft 3 4 shown in inches mm Mounting Dimensions sLON V2x rev1 03 2005 Shaft Requirements are ready to mount on 1 2 in 12.8 mm diameter damper shafts that extend at 2 in 51mm from the side of the terminal box mount controller on 3 8 in 9.5mm diameter damper shafts use AM 135 shaft adapter mount controller on shorter damper shafts between 3 4 in 19.1mm and 2 in 51mm the following Remove set screws from actuator collar Figure 2 Override Shaft Controller Srews Metal sLON VAV Controller Mounting Press manual override button and turn actuator collar to full counterclockwise position short shaft set screw holes are accessible Figure 3 Shaft Screw Short Shaft Set Screw Location set screws in short shaft set screw holes sLON V2x rev1 03 2005 Controller with Damper Closed in Clockwise CW Position Turn damper shaft to full closed CW position Press and hold manual override button and turn actuator collar to full CW position Release manual override button If necessary rotate actuator collar slightly to return to fully extended position Loosen output shaft set screws and slide controller over damper shaft until mounting contacts mounting area on VAV terminal Mounting foot can be moved from the factory shipped location to the side location Rotate controller CCW about three degrees off centerline of VAV terminal and tighten shaft set screws to 25 in lb 0.28 Kg meters See Figure 4 CW Mounting Rotate controller CCW to centerline of VAV terminal damper should be sealed Using controller mounting foot as a template mark and drill a pilot hole in VAV terminal Make certain mounting hole position does not affect performance of terminal box If movement is affected install mounting foot in side location Secure controller mounting foot using a 10 sheet metal screw Press and hold manual override button and rotate damper to full open position by damper shaft Release manual override button If necessary rotate actuator collar slightly to return to fully extended position Loosen and s