Solidyne sLON-V3 Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | solidyne-slon-v3-data-sheet-2413875906.pdf |
---|---|
Type | |
Size | 822.84 KB |
Downloads |
Text Preview
TECH DATA SHEET VAV Controller sLON V3 VAV Controllers are interoperable variable air volume controllers controllers provide pressure independent for cooling and reheat applications The sLON features sLON WTSx Digital Sensor support LED three digital relay outputs an integral pressure transducer and two triac outputs for with an external actuator This controller in standalone mode or as part of a LonWorks using the integral FTT 10 Free Topology transceiver A direct connection to a Communication adapter and a PC with Software Tool software is necessary to download modify applications Chart Digital Analog Triac UI Digital DI Strategy Config Type Cooling Series Fan Parallel Induction Staged Floating Time None Occupancy Satellite denotes LONMARK VAV Variable Air Volume profile and profile version Corporation www solidyne com rev1 03 2005 items not provided carton for damage If damaged notify carrier immediately Inspect controllers for Return damaged products must be a qualified technician Job wiring diagrams Tools Digital Volt ohm meter DVM Drill and bits for mounting screw Static protection wrist strap Class 2 power transformer supplying a nominal 24 VAC 20.4 to 30 VAC with a rating of 12 VA 50 60 Hz per controller plus Digital Output DO and Triac Each DO can be up to an additional 24VA maximum and each Triac load an 18VA maximum In European Community transformer must conform to 60742 Terminators One sLON T1 terminator required for free topologies Two sLON T2 terminators required for bus topologies Two 10 sheet metal screws 0.170 in 17 100 I D FRPE polyethylene tubing or 0.125 in 1 8 I D or 0.25 in 1 4 tygon tubing for piping connections Not more than five feet 1.52m long Electrical shock hazard Disconnect power before installing or removing the Follow Static precautions when installing this equipment Use copper conductors that are suitable for 167 75 Make all connections according to electrical wiring diagram national and local electrical Precautions charges damage electronic components The microprocessor and associated circuitry extremely sensitive to static discharge Use the following precautions when installing or operating the system Work in a static free area Discharge static electricity by touching a known securely grounded object Use a wrist strap connected to earth ground when handling the controller printed board Communications Commission FCC equipment has been tested and found to comply with the limits for a Class B digital pursuant to Part 15 of the FCC Rules These limits are designed to provide protection against harmful interference in residential installations This generates uses and can radiate radio frequency energy and may cause harmful if not installed and used in accordance with the instructions Even when are followed there is no guarantee that interference will not occur in a particular If this equipment causes harmful interference to radio or television reception can be determined by turning the equipment off and on user is encouraged to to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Connect the equipment to an outlet on a circuit different from that to which the receiver the separation between the equipment and receiver connected Consult the dealer or an experienced radio television technician for help rev1 03 2005 sLON V3x controllers are suitable for indoor use only Department of Communications DOC class B digital apparatus meets all requirements of the Canadian Interference Causing Regulations Community Directives equipment meets all requirements of European Community Directives for Low Voltage General Safety 92 59 EEC and Electromagnetic Compatibility Avoid locations where excessive moisture corrosive fumes vibration or explosive are present Avoid electrical noise interference Do not install near large contactors electrical or welding equipment Locate where ambient temperatures do not exceed 131 55 or fall below 32 and relative humidity does not exceed 85 or fall below 5 non condensing rev1 03 2005 Velocity Sensor either 0.170 in 17 100 I D FRPE polyethylene tubing or 0.125 in 1 8 I D or 0.25 in O D tygon tubing for piping connections Maximum length of tubing is five feet 1.52m Remove yellow plastic fitting caps from barbed fittings Connect tubing to barbed fittings on VAV Controller See Figure 2 controllers can be mounted in any direction and on any plane Mounting are shown in Figure 1 shown in inches mm Mounting Dimensions Velocity Sensor Differential Pressure Connections Connect tube from P1 fitting on controller to low pressure tap on VAV terminal See Connect tube from P2 fitting on controller to high pressure tap on VAV terminal See rev1 03 2005 Velocity Gauge a differential velocity pressure gauge to calibrate and verify central system is accurate pressure Figure 3 shows connections for attaching gauge When gauge removed restrictors must be plugged or removed from tubing Wall Shaft Flow cid 31 Pickup Tubing 0075 cid 31 Restrictors are cid 31 only when differential cid 31 pressure gauge is present velocity pressure cid 31 for calibration Magnehelic Series cid 31 MNL V3R cid 31 Controller Internal View of VAV Terminal Box with Triac Driven Motor and Pneumatic Tubing Detail rev1 03 2005 following electrical connections can be made to sLON V3x controllers Sensor Link S LK connection to an sLON WTSx LonWorks network LON connection LON connection from controller to an sLON WTS Sensor connections including One Universal Input UI One Digital Input DI One Analog Output AO Two Triac Outputs TO Three Digital Outputs DO Power connection to a 24 VAC nominal Class 2 EN 60742 power source and earth Figure 4 for wiring terminal information Input to 5 Vdc to 20mA Thermistor Balco Platinum Input Dry Input Contact one Sensor Network 3150 Transceiver Controller LEDs Service Pin Button Outputs Vac Class 2 VA per output Duty A Pole Single Throw Open Relay Power Vac 50 60 Hz 2 VA per Controller DO Loads detect a closed switch maximum resistance must be less than 300 ohms detect an open switch minimum resistance must be greater than 1.5K ohms signals of 1 to 11 Vdc must be converted to 0.45 to 5 Vdc with a voltage AD 8961 220 Applications which use 0 to 20 mA analog inputs require a 250 ohms shunt resistor kit Install resistor across universal input and common Applications which use