System Sensor B524RB Manual

Home » System Sensor B524RB Manual
File preview

File preview

Click the button below to download immediately for free

Download “System Sensor B524RB Manual” System_Sensor_B524RB_Manual.pdf – Downloaded 0 times – 635 KB


A Division of Pittway 3825 Ohio Avenue, St. Charles, Illinois 60174 FAX: 630-377-6495 AND MAINTENANCE INSTRUCTIONS and B224RB(A) Plug-in Detector Bases use with the following models: For use with any 500 Series detector For use with any 200 Series detector inches (157 mm) Diameter: Height Temperature Range: Humidity Range: Ratings Voltage: Averaged Standby Ratings: <500 @ 24 VDC Characteristics to 28 VDC coil latching Form C Type: Relay Time: Time: A @ 30 VDC A @ 110 VDC (with .35 PF or greater) A @ 120 VAC (with .35 PF or greater) A @ 30 VDC (with .6 PF or greater) seconds minimum, 20 seconds maximum second minimum, 8 seconds maximum inches (31 mm) inches (36 mm) square box with or without plaster ring, Min Depth - 1.5 inches (13 mm) octagon box, Min. depth - 1.5 inches (13 mm) octagon box, Min. depth - 1.5 inches (13 mm) to 49 C (32 to 120 F) to 93% Relative Humidity (Non-condensing) Installing thoroughly read the system wiring and installation and manual I56-407, Guide for Proper Use of Sys- Smoke Detectors, which provides detailed information detector spacing, placement, zoning, and special appli- Copies of these manuals are available at no charge System Sensor. (For installation in Canada, refer to Standard for the Installation for Fire Alarm and CEC Part 1, Sec. 32.) This manual should be left with the owner/user this equipment. The detector used with these bases must be and maintained regularly following NFPA 72 require- The detectors should be cleaned at least once a year. Information C latching relay contacts are included for the control an auxiliary function. The relay operates 12 seconds after activation of the sensor head remote an- output. detector base mounts directly to 31/2- and 4-inch oc- and 4-inch square boxes, with or without a plaster mount, remove the decorative ring by rotating it in ei- direction to unhook the snaps. Then, separate the ring the base. Install the base on the box, using the screws with the junction box and the appropriate slots in base. Replace the decorative ring on the base and ro- it in either direction until the ring snaps in place (see 1). Guidelines wiring must be installed in compliance with all appli- local codes and any special requirements of the local having jurisdiction, using the proper wire sizes. conductors used to connect smoke detectors to control and accessory devices should be color-coded to re- the likelihood of wiring errors. Improper connections prevent a system from responding properly in the event a fire. signal wiring (the wiring between interconnected de- it is recommended that the wire be no smaller 18 gauge (1.0 square mm). However, wire sizes up to gauge (3.3 square mm) can be used with the base. The of twisted pair wiring or shielded cable for the power and -) loop is recommended to minimize the effects of interference. shielded cable is used, the shield connection to and from detector must be continuous by using wire nuts, crimp- or soldering, as appropriate, for a reliable connection. system control panels have specifications for allow- loop resistance. Consult the control panel specifica- for the total loop resistance allowed before wiring the loops. Instructions base uses a latching relay that can change states if it is to mechanical shocks or jarring. As a result, even relay contacts are in the open state when the base is from the factory, the contacts may have closed shipment. an auxiliary control circuit to closed relay con- can cause an unexpected, and possibly dangerous, ac- of that circuit. Therefore, do NOT connect an control circuit to the relay contacts (terminals 1, and 3) before ensuring that the relay contacts are in their state. Ensure that the contacts are open by applying to the bases WITHOUT the sensor heads installed. wiring connections by stripping about 3/8" (10 mm) insulation from the end of the wire. Then, slide the wire the clamping plate and t [/bg_collapse]