System Sensor 2100S and 2100TS Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-2100s-and-2100ts-manual-5467123890.pdf |
---|---|
Type | |
Size | 640.65 KB |
Downloads |
Text Preview
3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 AND MAINTENANCE INSTRUCTIONS and 2100TS Photoelectronic Detectors including mounting bracket Temperature Range Model 2100S inches 140 mm inches 48 mm oz 150 g Humidity Range Alarm Sensor Model 2100TS only Ratings Voltage Ripple Voltage Capacitance Current Ratings Voltage Time Time to 120 0 to 50 2100TS 32 to 100 0 to 38 to 93 Relative Humidity Noncondensing by momentary power interruption Fixed Temperature Electronic Thermistor or 24 VDC VDC VDC of nom Voltage peak to peak maximum maximum VDC minimum at 10 mA VDC maximum at 130 mA current must be limited to 130 mA maximum by the control panel If the RA400Z Remote Annunciator operates within the specified detector currents VDC minimum seconds maximum seconds maximum after 60 second reset Installing thoroughly read System Sensor manual I56 407 for Proper Use of System Smoke Detectors which pro detailed information on detector spacing placement wiring and special applications Copies of this are available at no charge from System Sensor This manual shall be left with the owner user of equipment This detector must be tested and maintained following NFPA 72 requirements The detector be cleaned at least once a year Description 2100S is a 2 wire photoelectronic smoke detector uses a state of the art optical sensing chamber This is designed to provide open area protection and to used with compatible UL listed panels only Model features a restorable built in fixed temperature thermal detector of these detectors is simplified by the use of a bracket and a plug in screw terminal block that be prewired to the system allowing the detector to be installed or removed The detector sensitivity can tested in place using the MOD400R Test Module LED on the detector provides a local visual indication of detector status If power is applied to the detector and is functioning normally in standby mode within the listed ranges the status LED blinks once every ten sec The LED also provides a visual indication that main is required If the LED stops blinking the detector either not powered out of the listed sensitivity range unable to function properly The test switch will not if the detector is below the insensitive limit The will also latch on when the detector is in alarm 1 Surface mounting of 2100S smoke detec on 3 1 2 inch and 4 inch octagonal box devices should be color coded to reduce the like of wiring errors Improper connections can prevent system from responding properly in the event of a fire screw terminal block will accept 14 22 gauge wire best system performance all wiring should be installed separate grounded conduit do not mix fire system in the same conduit as any other electrical wiring pair may be used to provide additional protection extraneous electrical interference connections are made by stripping about 1 4 inch of from the end of the feed wire inserting the wire the appropriate terminal and tightening the screw to the wire in place Sensor smoke detectors are marked with a compat identifier located as the last digit of a five digit code on the back of the product Connect detectors only compatible control units as indicated in System Sensor chart which contains a current list of UL list compatible control units and detectors A copy of this is available from System Sensor upon request power from the control unit or initiating device before installing detectors Wire the plug in screw terminal block per Figure 3 and the terminal block into the detector Align the arrows on the detector with the arrows on the Turn the detector clockwise in the mounting bracket bracket it clicks into place After all detectors have been installed apply power to control unit or initiating device circuits Test the detector as described in TESTING See page 3 Reset the detector at the system control panel Notify the proper authorities the system is in operation RESISTANT TAB CUT OFF SMALL TAB TO ACTIVATE TAMPER RESIST FEATURE detectors also include an output that allows an option Model RA400Z Remote Annunciator to be connected 2100S and 2100TS detector is supplied with a mount bracket that permits the detector to be mounted To a single gang box or Directly to a 31 2 inch or 4 inch octagonal box or To a 4 inch square electrical box by using a plaster ring Directly to the ceiling using drywall anchors if permit by local codes and or the authority having jurisdic Feature detector includes a tamper resistant feature that pre its removal from the bracket without the use of a tool make the detector tamper resistant remove the smaller by breaking it at the scribed line on the tamper resist tab on the detector mounting bracket see Figure 2 install the detector To remove the detector from the once it has been made tamper resistant use a screwdriver to depress the tamper resistant tab locat in the slot on the mounting bracket and turn the detec counterclockwise Installation Guidelines wiring must be installed in compliance with the Electrical Code applicable local codes and any requirements of the local authority having jurisdic Proper wire gauges should be used The conductors to connect smoke detectors to control panels and 2 2100S and 2100TS smoke detector mounting bracket SLOT TAB TO DETECTOR E R V A 3 Wiring diagram for the 2100S and 2100TS detector LISTED RESISTOR BY CLASS A WIRING covers are an effective way to limit the entry of d