System Sensor 2D51
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-2d51-5918074263.pdf |
---|---|
Type | |
Size | 1.16 MB |
Downloads |
Text Preview
2D51 Duct Smoke for Applications System Sensor 2D51 low profile photoelectric smoke with a B210LP base tied to the D4P120 is listed Underwriters Laboratories 268A specifically for use in air handling systems for 2D51 B210LP D4P120 Low profile smoke detector design Low standby current Two LEDs blink in standby Detector head plugs easily into base Built in test switch Field sensitivity metering of detector to meet the requirements NFPA 72 with the use of RTS2 RTS2 AOS and SENS RDR Designed for mounting on a standard electrical box SEMS screws for easy wiring and positive wire retention Removable cover and insect screen for field cleaning Remote push button Test Reset LEDs provide visual indications Onboard supervisory and alarm relays Accepts 24 or 120V supply voltage Interconnect up to 100 units for common functions Compatible for interconnection with System Sensor InnoviarFlex or D4120W duct smoke detectors and remote accessories 2D51 can be used as a pendant mount detector in no flow air handling systems 0 4,000 FPM The pendant plenum 2D51 is to be installed into a B210LP base and wired to a power board only control unit The D4P120 power board is of controlling up to two 2D51 sensors mounted in a standard electrical box within the duct the head allows easy removal from the base for quick and maintenance The 2D51 heads can be locally tested a magnet or by using the test reset push button on the D4P120 board testing is accomplished using the RTS151 RTS151KEY or RTS AOS accessories connected to the D4P120 power APA151 RTS2 and RTS2 AOS Remote Annunciators with Piezo can also be connected to the D4P120 power board to provide audible and visible indication of smoke detector status Listings Photoelectric Detector Specifications Specifications air duct smoke detector shall be a System Sensor model 2D51 Series Smoke detector listed to UL 268A specifically for use in air handling when used in conjunction with the B210LP base The detector shall operate at air velocities up to 4,000 feet per minute It shall be of local testing using a magnet test on the 2D51 or using a test reset button on the D4P120 power board It can also be remotely using the RTS151 RTS151KEY RTS2 or RTS2 AOS connected to the D4P120 power board It shall be capable of providing duct detector status via the UL listed APA151 RTS2 and RTS2 AOS Piezo Annunciators Specifications Temperature Range Humidity Range Plug In Detector Base Specifications inches H 4.1 inches D oz 88 g to 158 20 to 70 to 95 relative humidity non condensing inches 155mm 102 mm square box with or without plaster ring Minimum Depth 1.5 inches 38 mm Octagon Box Minimum Depth 1.5 inches 38 mm Octagon Box Minimum Depth 1.5 inches 38 mm Gang Box Minimum Depth 1.5 inches 38 mm to applicable sensor Operating Temperature Range using the Base Sensor Cross Reference Chart systemsensor com Temperature Range Power Board Specifications Temperature Range Temperature Range Humidity Range Ratings supply voltage capacitance voltage time with RTS451 time by power down up time response time test Requirements Using No Accessories standby current VDC max VDC min to 0.3 sec sec max sec max sec detector label mA 24 VDC alarm current mA 24 VDC inches 19.45 cm Length 4.98 inches 12.64 cm Width 2.29 inches 5.81 cm Depth to 158 to 70 to 158 to 70 to 95 relative humidity non condensing lb 3 oz VAC 50 Hz max VAC min to 0.3 sec sec max sec max sec detector label VAC 50 Hz VAC min to 0.3 sec sec max sec max sec detector label mA RMS 24 VAC 60 Hz 20 mA RMS 120 VAC mA RMS 24 VAC 60 Hz mA RMS 120 VAC Hz A 30 VDC resistive A 30 VDC resistive 10A 250 VAC resistive HP 240 VAC HP 120 VAC Ratings initiation contacts auxiliary contacts Alarm auxiliary contacts shall not be connected to initiating circuits of control panels Use the alarm initiation contact for this purpose contacts SPDT Current Loads at 24 VDC Any combination of accessories may be used such that the given accessory loads are 110 mA or less at the Aux output and 50 mA or less mA Max mA Max mA Max mA Max strobe 55 mA max without strobe 30 mA max mA mA mA mA 12 mA mA max mA Max A 30 VDC resistive 2.0 A 125 VAC resistive the Alarm output Typical Wiring Diagrams PROOF 2 3 1 2 1 1 SELECTABLE SWITCHES 2 INSTALLED WIRE 1 2 VAC Y R B 1 A B LED 2 LED 1 INPUT VAC INPUT INPUTS NOTE 1 INPUTS NOTE 1 CONTACTS FAN SHUTDOWN ETC NOTE 2 A B CONTACTS FAN SHUTDOWN ETC NOTE 2 A B CONTACTS C 3 N O CONTACTS C 3 N O RESISTOR BY LISTED PANEL 4 N O C 4 N O C DETECTOR IN THE LOOP DETECTOR IN THE LOOP 1 24V Power Inputs accept a non polarized 24 VDC or 24 VAC 120 VAC Power Inputs accept only 120 VAC 50 60 Connect power source to appropriate terminals of each See specifications for additional power supply 2 Auxiliary contacts shown in standby position Contacts during alarm as indicated by arrows Auxiliary are not to be used for connection to the control See specifications for contact ratings 3 Supervisory contacts shown in standby position Open indicate a trouble condition to the panel See for contact ratings 4 Alarm Initiation contacts shown in standby position Closed indicate an alarm condition to the panel See for contact ratings Please refer to the corresponding installation manual for detailed installation instructions and accessory wiring diagrams Sensor provides system flexibility with a variety of accessories including two remote test stations and several different means of and audible system annunciation As with our duct smoke detectors all duct smoke detector accessories are UL listed UL S4011 UL S2522 UL S4011 UL S2522 UL S2522 UL S4011 Mount in Ventilation Shaft Power Board Informat