System Sensor 500 Series Intelligent Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-500-series-intelligent-modules-8234056917.pdf |
---|---|
Type | |
Size | 730.07 KB |
Downloads |
Text Preview
500 Series Modules System Sensor intelligent module products are to meet a wide range of applications SEMS screws for easing wiring Panel controlled status LED except M501M Analog communications Rotary address switches except M500X Low standby current Mounts in standard 4 junction box Listings and control modules can be used to supervise and sounders strobes door closers pull stations waterflow conventional smoke detectors and more Each module rigorously designed and tested for electromagnetic compatibility environmental reliability in many cases exceeding industry Modules are addressed with easy to use rotary switches Full size modules mount in standard 4 in 4 in 21 in junction box Wiring terminals are easily accessible for Monitor Module M501M Mini Monitor Module M500DM Dual Input Monitor Module Sensor monitor modules provide an interface to contact such as security contacts waterflow switches or pull M501M and M500DM are capable of Class B supervised to the monitored device M500M is capable of Class A Conventional 4 wire smoke detectors can be monitored their alarm and trouble contacts wired as an initiating loop the module In addition to transmitting the supervised state of the device normal open or short the full analog supervision is sent back to the panel This allows detection of changes in the supervised loop to the monitored device M500DM module is capable of monitoring two separate Class B simultaneously making it ideal for waterflow tamper switch flow switch monitoring The compact size of the M501M module it to fit inside devices or junction boxes behind devices Isolator Module M500X Isolator Module is an automatic switch that opens when line voltage drops below four volts Isolator modules should be between groups of sensors or modules in a loop to protect rest of the loop If a short occurs between any two isolators then isolators immediately switch to an open circuit state and isolate devices between them The remaining units on the loop continue fully operate The number of devices that can be installed between modules varies depending on the device type Please see module s manual for more information Zone Interface Module M502M Zone Interface Module allows intelligent panels to and monitor 2 wire conventional smoke detectors All detectors being monitored must be UL or ULC compatible the module The M502M module is addressed through the line of an intelligent system It transmits the status of zone of 2 wire detectors to the fire alarm control panel Status are reported as normal open or alarm The interface supervises the zone of detectors and the connection of the power supply Control Module M500S Control Module provides supervised monitoring of wiring load devices that require an external power supply to operate as horns strobes or bells It is capable of Class A and Class supervision Upon command from the control panel the M500S will disconnect the supervision and connect the external supply across the load device The disconnection of the provides a verification to the panel that the control actually turned on The external power supply is always relay from the communication loop so that a trouble condition on power supply will never interfere with the rest of the system Full measurement of the supervised wiring is transmitted back to panel and can be used to detect impedance changes or other test functions Relay Module M500R Relay Module contains two isolated sets of Form C which operate as a DPDT switch The module allows the panel to switch these contacts on command No supervision provided for the notification appliance circuit Firefighter Phone Module M500FP module is intended to monitor and control a loop of phones It has the ability to differentiate between normal and trouble conditions When taken off hook a phone will receive a ringing tone and the panel will receive an off indication The panel can then connect that off hook phone to main riser for the system Series Intelligent Module Specifications Specifications Voltage Line Impedance Range Humidity Weight to 32 VDC max to 120 0 to 49 to 93 noncondensing 1.2 oz 37 g 6.3 oz 196 g 2.7 in W 1.7 in H 0.5 in D 4.275 in W x 4.675 in H x 1.4 in D M500X Current Impedance Detection Delay Detection Threshold Restoration Threshold M500DM Current Current M502M Current Power Supply Resistance Supply Current Supply Current M500R Current Current Contact Ratings max 24 VDC one every 5 sec LED enabled to 28 VDC 100 mV ripple max k included mA 24 VDC nominal mA 24 VDC nominal Resistance M500M M500S M501M Current max 24 VDC communication every 5 sec with enabled mA with LED latched on A 25 VAC PF 35 non coded A 30 VDC resistive non coded A 30 VDC resistive coded A 30 VDC L R 20ms non coded A 70.7 VAC PF 35 non coded A 125 VDC resistive non coded A 125 VAC PF 75 non coded A 125 VAC PF 35 non coded Resistance M500FP Current Line Current Phone Resistance max k to 2.9 k ms min Volts Volts max 24 VDC one every 5 sec with EOL max one communication 5 sec 6 mA with latched on k two included max 24 VDC one every 5 sec with EOL 600 max 24 VDC communication every 5 sec EOL 1k 5.5 mA with LED on k included mA max one communication 5 sec with LED enabled mA max no communication off 1200 phone nominal k included Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 specifications subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 02 15