System Sensor 500 Series Multiple Input Output Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-500-series-multiple-input-output-modules-7618504329.pdf |
---|---|
Type | |
Size | 928.46 KB |
Downloads |
Text Preview
500 Series Input and Modules Sensor multiple input and output modules designed to meet a range of applications in which single modules are used Removable 12 to 18 AWG plug in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class A or B operation Mount up to two modules in BB 2 enclosure optional Mount up to six modules in BB 6 enclosure with CH 6 chassis Mounting hardware included Listings design of the System Sensor 500 Series multiple input and modules allows for installation ease and time savings The and control modules can be used to supervise and activate strobes door closers pull stations waterflow switches smoke detectors and more The conventional zone module is ideal for retrofit applications to monitor zones of two wire detectors Each module has its own address are addressed with easy to use rotary code switches are included for disabling unused addresses Up to two mount in a BB 2 enclosure with built in chassis and up to modules mount in a BB 6 enclosure with the CH 6 chassis Wiring are easily accessible for trouble shooting purposes SIX RELAY CONTROL MODULE CR 6 Six Relay Control module consists of six Form C relays first address is set from 01 to 94 while the remaining modules automatically assigned to the next five higher addresses are included for disabling a maximum of three unused A single isolated set of dry relay contacts is provided for module address which is capable of being wired for either a open or normally closed operation The module allows the panel to switch these contacts on command No supervision provided for the controlled circuit SIX SUPERVISED CONTROL MODULE SC 6 Six Supervised Control module provides supervised of wiring to load devices that require an external power or amplifier to operate such as horns strobes speakers bells Upon command from the control panel the SC 6 will the supervision and connect the external power supply the load device The first module is addressed from 01 to 94 the remaining modules are assigned to the next five higher Provisions are included for disabling a maximum of unused modules Each module has terminals for connection an external supply circuit for powering devices on its notification circuit One or multiple power supplies or amplifiers may used TEN INPUT MONITOR MODULE IM 10 Ten Input Monitor module provides an interface between control panel and normally open contact devices such as pull security contacts or flow switches The first address is from 01 to 90 and the remaining modules are automatically to the next nine higher addresses Provisions are included disabling a maximum of two unused addresses The supervised normal open or short of the monitored device is sent back to panel SIX ISOLATOR MODULE ISO 6 Six Isolator Module is an automatic switch that opens the line voltage drops below four volts Isolator modules be spaced between groups of sensors or modules in a loop protect the rest of the loop If a short occurs between any two then both isolators immediately switch to an open circuit and isolate the devices between them The remaining units on loop continue to fully operate INPUT TWO OUTPUT MODULE multiple module combines two relay outputs and two monitor into one device The module is capable of Class B supervised to the monitored devices It also contains Form C relay allowing the panel to switch the contacts on command is a dedicated LED on the module for each input and output control panel can use these bi color LEDs to indicate normal and alarm conditions is a short circuit protection monitor for each module This provided to protect the external power supply against short conditions on the NAC When an alarm condition occurs relay which connects the external supply to the NAC will not be to close if a short circuit condition currently exists on the In addition an algorithm is incorporated to find a short when module is active The module will close all circuits that are not to find the NAC with the problem ACCESSORY CARD SYNC 1 is an optional accessory to the SC 6 and is designed provide a means of synchronizing a series of horns strobes and The SYNC 1 is able to synchronize the temporal coded the one second flash timing of the strobe and silencing the of the horn strobe combination over a two wire circuit while the strobes active Each SYNC 1 accessory card has the of synchronizing six Class B circuits or three Class A SIX ZONE INTERFACE MODULE CZ 6 Six Zone Interface module provides an interface between intelligent alarm system and a two wire conventional detection A common SLC input is used for all modules and the initiating circuits share a common external supply Otherwise each operates independently from the others The first module addressed from 01 to 94 while the remaining modules are to the next five higher addresses Provisions are included disabling a maximum of two unused modules All two wire being monitored must be two wire compatibility listed the modules The CZ 6 transmits the status of a zone of two detectors to the fire alarm control panel Status conditions are as normal open or alarm The interface module supervises zone of detectors and the connection of the external power to 32 VDC Ohms Series Module Specifications Specifications Voltage SLC Wiring Range Humidity Gauge CR 6 Current Current to 120 0 to 49 to 85 noncondensing to 18 AWG in H 5.8 in W 1.25 in D mA maximum mA maximum assumes all six relays been switched once and all six solid on Ohms mA Relay Pulse 15.6 mS pulse pulse under panel control product installation manual mA maximum mA maximum all six LEDs solid on Ohms IDC Wiring Current Contact Ratings CZ 6 Current Current Detectors SC 6 Current Current IM 10 Current Current mA maximum mA maximum all ten LEDs solid on Ohms VDC mA IDC Wiring IDC Voltage IDC Current ISO 6 Current Current Draw Two Input and Two Output Module Current mA mA Resistance SYNC 1 Voltage Load on a Loop Current in H x 4.275 in W x 1.4 in D mA one communication every sec with 47k EOL kOhms two included to 30 VDC A Style Z 3A A Style Y 3A per pair Position 15 mA or 4 Position if connected to 2.5 mA IDC Wiring Supply Voltage DC Voltage 18 to 28 volts power limited Voltage 0.1 volts RMS maximum 90 mA per circuit System Sensor for a current list BB 2 Enclosure BB 6 Enclosure 9 3.67 12.55 6.47 mA maximum mA maximum assumes all six relays been switched once and all six solid on Ohms NAC Circuit Resistance Rating Per Circuit 50 W 70.7 VAC Accessory Card Enclosure with CH 6 Chassis Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 specifications subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 4 14