System Sensor 5151 Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-5151-manual-4719286305.pdf
Type PDF
Size 1.15 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Plug In Heat Detector Temperature Range Humidity Range voltage Current Current Alarm inches 42 mm inches 102 mm oz 80g to 100 0 to 38 to 93 Relative Humidity noncondensing to 35VDC 24VDC Min 130mA Max Must be limited by control panel by momentary power interruption 57 Fixed or 15 rate of rise Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 INSTALLING detector must be installed in compliance with the control panel installa manual and meet the requirements of the authority having jurisdiction the National Fire Protection Association has published codes stan and recommended practices for the installation and use of detectors 72 the installer must be familiar with these requirements with local and any special requirements of the authority having jurisdiction This manual should be left with the owner user of this equipment The detector must be tested and maintained regularly following 72 requirements The detector should be cleaned at least once a year DESCRIPTION 5151 is a rate of rise with fixed temperature alarm conventional 2 wire detector This detector is designed to provide open area protection 50 foot spacing capability as approved by UL 521 RTI rating is classified FAST in accordance with FM 3210 LEDs on each detector provide local 360 visible alarm indication They every five seconds indicating that power is applied and the detector working properly The LEDs latch on in alarm LEDs will be off when a condition exists indicating that the detector sensitivity is outside the limit Remote LED annunciator capability is standard and may be imple through an optional accessory RA100Z The alarm can be reset only a momentary power interruption This detector may be tested by activating internal reed switch with a magnet WIRING GUIDE to the installation instructions for the plug in detector base for electrical and wiring instructions The base provides screw terminals for and remote annunciator connections All wiring must conform to applicable local codes ordinances and Verify that all detector bases are installed that the initiating device have been tested and that the wiring is correct Refer to detector base for testing procedure power from initiating device circuits before installing detectors detectors Tamper Resistance Place the detector into the detector base Turn the detector clockwise until the detector drops into place Continue turning detector clockwise to lock it in place The detector bases can be made tamper resistant When capability enabled detectors cannot be removed from the base without the of a tool See the detector base installation manual of the detector for details in using this capability After all detectors have been installed apply power to the control unit Test the detector using the magnet as described under TESTING Reset the detector at the system control panel Notify the proper authorities that the system is back on line RESISTANCE detector bases include a feature that when activated prevents removal the detector without the use of a tool Refer to the installation instruction of the detector base to make use of this capability testing notify the proper authorities that the smoke detector system is maintenance and will temporarily be out of service Disable the or system undergoing maintenance to prevent unwanted alarms Detec must be tested after installation and as part of periodic maintenance Test as follows Before testing the detector check to ensure the LEDs blink If they do the detector has lost power check the wiring it is defective return it for or the detector sensitivity is outside the listed limits Test Magnet p n M02 04 01 or M02 09 00 Place the magnet against the cover in the location designated by the mark to activate the test feature see Figure 1 The LEDs should latch ON within 5 seconds indicating alarm and annun the panel Direct Heat Method Hair dryer of 1000 1500 watts A hair dryer of 1000 1500 watts should be used to test the thermistor the heat toward the thermistors holding the heat source approxi 12 inches from the detector in order to avoid damaging the plastic The LEDs on the detector should light when the temperature at the de reaches the set point Reset the detector at the system control panel The detector will reset after it has had sufficient time to cool the proper authorities that the system is back on line that fail these tests should be cleaned as described under MAIN and retested If the detectors still fail these tests they should be for repair Before cleaning notify the proper authorities that the system is under maintenance and therefore the system will temporarily be out of ser Disable the loop or system undergoing maintenance to prevent unwanted is recommended that the sensor be removed from its mounting base for cleaning and that sensors be cleaned at least once a year Use a vacuum to remove dust from the sensing chamber 1 VIEWS SHOWING POSITION Of TEST MAGNET MAGNET 2 refer to insert for the Limitations of Fire Alarm Systems LIMITED WARRANTY Sensor warrants its enclosed heat detector to be free from defects in materials workmanship under normal use and service for a period of three years from date of System Sensor makes no other express warranty for this heat detector No representative dealer or employee of the Company has the authority to increase alter the obligations or limitations of this Warranty The Company obligation of this shall be limited to the repair or replacement of any part of the heat detector is found to be defective in materials or workmanship under normal use and ser during the three year period commencing with the date of manufacture After phon System Sensor toll free number 800 SENSOR2 736 7672 for a Return Authorization send defective units postage prepaid to System Sensor Repair Department RA 3825 Ohio Avenue St Charles IL 60174 Please include a note describing malfunction and suspected cause of failure The Company shall not be obligated to or replace units which are found to be defective because of damage unreasonable modifications or alterations occurring after the date of manufacture In no case shall Company be liable for any consequential or incidental damages for breach of this any other Warranty expressed or implied whatsoever even if the loss or damage is by the Company negligence or fault Some states do not allow the exclusion or of incidental or consequential damages so the above limitation or exclusion not apply to you This Warranty gives you specific legal rights and you may also other rights which vary from state to state System Sensor

Related Files