System Sensor 5600 Series Heat Detectors Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-5600-series-heat-detectors-manual-9847031526.pdf
Type PDF
Size 738.52 KB
Downloads

Text Preview

I 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 AND MAINTENANCE INSTRUCTIONS Series Heat Detector Circuit 5601P 5602 5603 5604 Circuit 5621 5622 5623 5624 Voltage Contact Ratings Resistive Installation Temperature Temperature Threshold Humidity Range Terminals Box Mounting with mounting bracket 125 VAC 3A 28 VDC 1A VDC 0.3A VDC 0.1A 5601P 5603 5621 and 5623 100 38 5602 5604 5622 and 5624 150 65.6 5601P 5603 5621 and 5623 135 57 5602 5604 5622 and 5624 194 90 8.3 per minute 5601P 5602 5621 and 5622 only to 95 RH non condensing 22 AWG octagonal octagonal gang square with a square to round plaster ring 4.57 inches 11.6cm 1.69 inches 4.3cm oz 170 grams prevent the activation of the fixed temperature element the shipping and storage temperature must not 122 50 Installing detector must be installed in compliance with control panel installation manual and meet the of NFPA 72 and or the local authority jurisdiction this manual carefully before using the detec This manual should be left with the owner user this equipment Description 5600 series mechanical heat detector is in for use in property protection applications for non life safety installations where smoke de is not practical or appropriate life safety installations smoke detectors must used in lieu of or in addition to mechanical heat 5600 series consists of both single and dual heat detectors featuring fixed temperature sensors or combination fixed temperature sensors with temperature ratings of 135 or 194 90 on the exterior of the detector indicate the activation method and temperature rating All are identified as either 135 or 194 Models equipped with combination fixed tem sensors are marked FX ROR temperature only models are marked FX Fixed Temperature Sensor fixed temperature element reacts to heat by re to a specific temperature setting 135 194 The detection method is based on the action of a metal contact held to the metal by a fusible alloy When the temperature the alloy melting point the metal contact depress the diaphragm causing the electrical to close the circuit The circular external collector is released from the detector to visu indicate that the detector has been activated 5600 series Fixed Temperature models 5603 5623 and 5624 are non resettable and can be tested 1 5600 Series Mechanical Heat Detectors Temperature Sensor Maximum Spacing 57 90 57 90 57 90 57 90 Temperature Rate of Rise Temperature Rate of Rise Temperature Temperature Temperature Rate of Rise Temperature Rate of Rise Temperature Temperature ceiling x 50 feet x 50 feet x 25 feet x 25 feet x 50 feet x 50 feet x 25 feet x 25 feet Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet Classification ratings are for installations which must comply with FM 3210 Detector Type 135 RTI Classification and Fixed 135 RTI FAST and SPECIAL Respectively 194 RTI and Fixed 194 RTI FAST and SPECIAL Respectively Rate of Rise ROR Sensor rate of rise element responds to a rapid rise of approximately 15 8.3 per min As the temperature rises the air within the chamber expands Should the chamber air faster than it can escape through the cali vent the diaphragm is depressed and the contact closes the circuit Only the ROR element of 5600 series com fixed temperature ROR models 5601P 5621 and 5622 are self restoring and may be using a hair dryer or heat gun When testing ROR element to prevent the activation of the temperature element the heat source must not the fixed temperature rating of the detector Bracket 5600 series detectors are equipped with a mount bracket that includes mounting slots to accom single gang 31 octagonal and 4 octagonal boxes as well as 4 square boxes equipped a plaster ring Figure 1 The mounting bracket reversible to accommodate flush mount and sur installations Figure 2 Installation Guidelines wiring must be installed in compliance with the Electrical Code applicable state and local and any special requirements of the local Having Jurisdiction Proper wire gauges be used The conductors used to connect detectors to the alarm control panel and ac devices should be color coded to reduce the 1 Bracket Mounting Locations 2 Reversible Mounting Bracket 31 Octagonal box 4 Octagonal box Single gang box and 4 square with plaster ring Directly to Wall Ceiling of wiring errors Improper connections prevent a system from responding properly in event of a fire non polarized screw terminals on the back of detector will accept 14 AWG wire For best performance all wiring should be installed separate grounded conduit do not mix fire alarm wiring in the same conduit as any other wiring Twisted pair may be used to pro additional protection against extraneous elec interference connections are made by stripping approxi 1 of the insulation from the end of the feed inserting it into the proper base terminal and the screw to secure the wire in place 3 Wiring Diagram Single Circuit Models power from the alarm control unit or initi device circuits before installing detectors Detach the detector from the mounting bracket by the detector 1 turn counter clockwise Orient the mounting bracket properly for either a or surface mount installation Figure 2 Select the pair of mounting holes suitable for the box Figure 1 and secure the bracket the box Connect the wires to the detector per Figure 3 or 4 as applicable Place the detector onto the mounting bracket by clockwise The detector will lock into with a After all detectors have been installed apply to the alarm control unit Test each detector as described in Testing Reset all the detectors at the alarm control unit Notify the proper authorities that the system is operation 4 Wiring Diagram Dual Circuit Models rate of rise mechanism may be subject to re sensitivity over time Annual testing of the operation is therefore recommended testing notify the proper authorities that is being performed and the system will temporarily out of service Disable the zone or undergoing maintenance to prevent any un alarms the ROR element of 5600 series combination temperature ROR models 5601P 5602 5621 5622 are self restoring and may be tested us a hair dryer or heat gun testing the ROR element to prevent the ac of the fixed temperature element the heat must not exceed the fixed temperature rating the de

Related Files